BS EN 60229:2008
Current
The latest, up-to-date edition.
Electric cables. Tests on extruded oversheaths with a special protective function
Hardcopy , PDF
English
31-07-2008
1 Scope
2 Normative references
3 Routine tests
3.1 D.C. voltage test
3.2 Spark test
4 Type tests
4.1 Abrasion test
4.1.1 Purpose
4.1.2 Test procedure
4.1.3 Inspection
4.1.4 Performance requirement
4.2 Corrosion spread (aluminium metallic screen only)
4.2.1 General
4.2.2 Test procedure
4.2.3 Inspection
4.2.4 Performance requirement
5 Electrical test after installation
Annex A (normative) - Application of the abrasion test
Annex B (informative) - Guidance on tests after installation
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Describes a range of tests which may be required for electric cables which have an extruded oversheath and where that oversheath performs a special protective function.
Committee |
GEL/20/16
|
DevelopmentNote |
Supersedes 05/30136422 DC. (09/2008)
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard provides a range of tests which may be required for electric cables which have an extruded oversheath and where that oversheath performs a special protective function. NOTE 1 The need for the special functions may be independent of the nature of the insulation type or independent of the rated voltage of the cable. The standard covers cables for use in insulated systems and in uninsulated systems. The tests are categorized for use as routine tests, type tests, tests after installation. These tests comprise: electrical routine tests on cable oversheath used in insulated or uninsulated systems, abrasion and corrosion spread type tests, electrical test on cable oversheath after installation. Routine tests and tests after installation, as specified in the relevant cable standards, are applicable for all situations. Type tests depend upon the nature of the system and the construction of the cable and do not have to be carried out for normal conditions of use. The application of the abrasion test is given in Annex A. NOTE 2 Guidance on tests after installation is given in Annex B.
Standards | Relationship |
EN 60229:2008 | Identical |
IEC 60229:2007 | Identical |
BS 7889:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000 V, for fixed installations |
12/30244462 DC : 0 | BS 8573 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS, HAVING LOW EMISSIONS OF SMOKE AND CORROSIVE WHEN AFFECTED BY FIRE |
BS 7846:2015 | Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
15/30301501 DC : 0 | BS 5467 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, FOR FIXED INSTALLATIONS - SPECIFICATION |
BS 7912(2012) : 2012 | POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
BS 6724:2016 | Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
12/30244367 DC : 0 | BS 7912 - POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
15/30301742 DC : 0 | BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS |
BS 5467:2016 | Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations. Specification |
15/30301443 DC : 0 | BS 6724 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1 900/3300 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION |
BS 8573:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire |
12/30244369 DC : 0 | BS 7889 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS |
IEC 60230:1966 | Impulse tests on cables and their accessories |
IEC 62230:2006+AMD1:2013 CSV | Electric cables - Spark-test method |
EN 60230:2002 | Impulse tests on cables and their accessories |
EN 62230:2007/A1:2014 | ELECTRIC CABLES - SPARK-TEST METHOD |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.