FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-1998

£218.00
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Definitions and abbreviations
   3.1 Definitions
   3.2 Abbreviations
4 General requirements
5 General requirements for indications
   5.1 Display of functional conditions
   5.2 Display of indications
   5.3 Indications on alphanumeric displays
   5.4 Indication of the supply of power
   5.5 Audible indications
   5.6 Additional indications
6 The quiescent condition
7 The fire alarm condition
   7.1 Reception and processing of fire signals
   7.2 Indication of the fire alarm condition
   7.3 Indication of the zones in alarm
   7.4 Audible indication
   7.5 Other indications during the fire alarm condition
   7.6 Reset from the fire alarm condition
   7.7 Output of the fire alarm condition
   7.8 Output to fire alarm devices (option with
         requirements)
   7.9 Control of fire alarm routing equipment (options
         with requirements)
   7.10 Outputs to fire protection equipment (option with
         requirements)
   7.11 Delays to outputs (option with requirements)
   7.12 Dependencies on more than one alarm signal
         (options with requirement)
   7.13 Alarm counter (option with requirements)
8 Fault warning condition
   8.1 Reception and processing of fault signals
   8.2 Indication of faults
   8.3 Fault signals from points (option with
         requirements)
   8.4 Total loss of the power supply (option with
         requirements)
   8.5 System fault
   8.6 Audible indication
   8.7 Reset of fault indications
   8.8 Fault output
   8.9 Output to fault warning routing equipment
         (option with requirements)
9 Disabled condition
   9.1 General requirements
   9.2 Indication of the disabled condition
   9.3 Indication of specific disablements
   9.4 Disablements and their indication
   9.5 Disablement of addressable points (option with
         requirements)
10 Test condition (option with requirements)
   10.1 General requirements
   10.2 Indication of the test condition
   10.3 Indication of zones in the test state
11 Standardized input/output interface
   (option with requirements)
12 Design requirements
   12.1 General requirements and manufacturer's
         declarations
   12.2 Documentation
   12.3 Mechanical design requirements
   12.4 Electrical and other design requirements
   12.5 Integrity of transmission paths
   12.6 Accessibility of indications and controls
   12.7 Indications by means of light emitting indicators
   12.8 Indications on alphanumeric displays
   12.9 Colours of indications
   12.10 Audible indications
   12.11 Testing of indicators
13 Additional design requirements for software controlled
   control and indicating equipments
   13.1 General requirements and manufacturer's
         declarations
   13.2 Software documentation
   13.3 Software design
   13.4 Program monitoring
   13.5 The storage of programs and data
   13.6 The monitoring of memory contents
   13.7 Operation of the c.i.e. in the event of a
         system fault
14 Marking
15 Tests
   15.1 General
   15.2 Functional test
   15.3 Environmental tests
   15.4 Cold (operational)
   15.5 Damp heat, steady state (operational)
   15.6 Impact (operational)
   15.7 Vibration, sinusoidal (operational)
   15.8 Electromagnetic Compatibility (EMC),
         Immunity tests
   15.13 Supply voltage variation (operational)
   15.14 Damp heat, steady state (endurance)
   15.15 Vibration, sinusoidal (endurance)
Annexes
A (informative) Explanation of access levels
B (informative) Optional functions with requirements
                 and alternatives
C (informative) Processing of signals from fire detectors
D (informative) Explanation of zones and the zonal indication
                 of fire alarms
E (informative) Delays to outputs
F (informative) Fault recognition and indication
G (informative) Standardized input/output interface
                 for the connection of ancillary equipment
                 (e.g. a fire brigade panel)
H (informative) Integrity of transmission paths
I (informative) Design requirements for software
                 controlled control and indicating equipments
ZA (informative) Clauses addressing the provisions of the EU
                 Construction Products Directive (89/106/EEC)
Bibliography

Defines requirements, test procedures and performance criteria for control and indicating equipment to be used in fire detecting and fire alarm systems installed in buildings.

Committee
FSH/12/3
DevelopmentNote
Together with BS EN 54-4 supersedes BS 5839-4(1988) Supersedes 85/38335 DC (12/2002) Supersedes 00/540034 DC and 04/30115583 DC. (01/2007)
DocumentType
Standard
Pages
40
PublisherName
British Standards Institution
Status
Current
Supersedes

07/30160342 DC : 0 BS 7273-3 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 3: ELECTRICAL ACTUATION OF PRE-ACTION WATERMIST AND SPRINKLER SYSTEMS
12/30260280 DC : 0 BS 5839-6 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 6: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE OF FIRE DETECTION AND FIRE ALARM SYSTEMS IN DOMESTIC PREMISES
BS 5839-6:2013 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises
BS 7273-4:2015 Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors
BS 5839-1(2002) : 2002 FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
BS 5839-9:2003 Fire detection and alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems
BS 5839-1:2017 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
BS 5839-9:2011 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems
12/30260278 DC : 0 BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
12/30258581 DC : 0 BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS
11/30176548 DC : 0 BS 7827 - CODE OF PRACTICE FOR DESIGNING, SPECIFYING, MAINTAINING AND OPERATING EMERGENCY SOUND SYSTEMS AT SPORTS VENUES
01/540648 DC : DRAFT MAY 2001 BS 5839-9 FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - PART 9: CODE OF PRACTICE FOR EMERGENCY VOICE COMMUNICATION SYSTEMS
06/30133094 DC : DRAFT OCT 2006 BS 7273-4 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 4: ACTUATION OF RELEASE MECHANISMS FOR DOORS
BS 7273-3:2008 Code of practice for the operation of fire protection measures Electrical actuation of pre-action watermist and sprinkler systems
BS 7273-1:2006 Code of practice for the operation of fire protection measures Electrical actuation of gaseous total flooding extinguishing systems
BS 7273-1:2000 Code of practice for the operation of fire protection measures Electrical actuation of gaseous total flooding extinguishing systems
BS 7827:2011 Code of practice for designing, specifying, maintaining and operating emergency sound systems at sports venues
PD 6531:2010 Queries and interpretations on BS 5839-1
07/30160345 DC : 0 BS 7273-5 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 5: ELECTRICAL ACTUATION OF WATERMIST SYSTEMS
BS 5908-2:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations
03/119007 DC : DRAFT DEC 2003 BS 5839-6 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 6: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION AND MAINTENANCE OF FIRE DETECTION AND FIRE ALARM SYSTEMS IN DWELLINGS
BS 7273-4:2007 Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors
BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
EEMUA 138 : 2010 DESIGN AND INSTALLATION OF ON-LINE ANALYSER SYSTEMS
PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
BS 5908-1:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Code of practice for precautions against fire and explosion in chemical plants, chemical storage and similar premises
15/30288999 DC : 0 BS 7273-4 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 4: ACTUATION OF RELEASE MECHANISMS FOR DOORS
01/540647 DC : DRAFT MAY 2001 BS 5839-1 - FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - PART 1 - CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION AND MAINTENANCE
BS 7273-5:2008 Code of practice for the operation of fire protection measures Electrical actuation of watermist systems (except pre-action systems)
PD 7974-4:2003 Application of fire safety engineering principles to the design of buildings Detection of fire and activation of fire protection systems. (Sub-system 4)
09/30187281 DC : 0 BS 5839-9 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 9: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE OF EMERGENCY VOICE COMMUNICATION SYSTEMS
BS 7273-3:2000 Code of practice for the operation of fire protection measures Electrical actuation of pre-action sprinkler systems
BS 5839-6:2004 Fire detection and fire alarm systems for buildings Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings

93/68/EEC : 1993 AMD 2 1998 COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
89/106/EEC : 1988 COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
IEC 60068-2-3:1969 Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
ISO 9001:2015 Quality management systems — Requirements
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
EN 60068-2-47:2005 Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests
EN 60721-3-3 : 95 AMD 2 97 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.