BS EN 50413 : 2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
BASIC STANDARD ON MEASUREMENT AND CALCULATION PROCEDURES FOR HUMAN EXPOSURE TO ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ)
Hardcopy , PDF
30-11-2019
English
01-01-2009
1 Scope
2 Normative references
3 Definitions
4 Introduction
5 Assessment of human exposure by measurement
6 Assessment of human exposure by calculation
7 Phantoms for measurement and computation
8 Assessment report
9 References
Annex A (informative) - Analytical models for
validation of calculation methods
Annex B (informative) - Numerical methods
Annex C (informative) - Uncertainty assessment
for the measurement of EMF
Annex D (informative) - Consideration of different
types of radio transmission (modulation)
Bibliography
Describes elements to establish methods for measurement and calculation of quantities associated with the assessment of human exposure to electric, magnetic and electromagnetic fields (EMF) in the frequency range from 0 Hz to 300 GHz.
Committee |
GEL/106
|
DevelopmentNote |
Supersedes 02/205824 DC. (02/2009) AMD 1 2013 aligns BSI & CEN Edition. 2009 Edition Re-Issued in November 2013 as '2008 + A1 2013' & incorporates AMD 1 2013. 2009 version remains current. (11/2013)
|
DocumentType |
Standard
|
Pages |
52
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
Supersedes |
Standards | Relationship |
EN 50413 : 2008 AMD 1 2013 | Identical |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 62226-3-1:2007/A1:2017 | EXPOSURE TO ELECTRIC OR MAGNETIC FIELDS IN THE LOW AND INTERMEDIATE FREQUENCY RANGE - METHODS FOR CALCULATING THE CURRENT DENSITY AND INTERNAL ELECTRIC FIELD INDUCED IN THE HUMAN BODY - PART 3-1: EXPOSURE TO ELECTRIC FIELDS - ANALYTICAL AND 2D NUMERICAL MODELS (IEC 62226-3-1:2007/A1:2016) |
EN 62226-2-1:2005 | Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field induced in the human body - Part 2-1: Exposure to magnetic fields - 2D models |
ENV 13005 : DRAFT 1999 | GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT |
ETR 200028 : 20002 | RADIO EQUIPMENT & SYSTEMS (RES) - UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS |
IEC 62226-2-1:2004 | Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field induced in the human body - Part 2-1: Exposure to magnetic fields - 2D models |
IEC 62226-3-1:2007+AMD1:2016 CSV | Exposure to electric or magnetic fields in the low and intermediatefrequency range - Methods for calculating the current density and internal electric field induced in the human body - Part 3-1: Exposure to electric fields - Analytical and 2D numerical models |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.