BS EN 50393:2015
Current
The latest, up-to-date edition.
Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV
Hardcopy , PDF
English
28-02-2015
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Components
5 Electrical characteristics
6 Range of compliance
7 Type tests
8 Test methods
Annex A (informative) - Determination of cable conductor
temperature
Annex B (informative) - Identification of test cable
Annex C (informative) - Identification of accessory test
samples
Annex D (informative) - Identification of connector
Bibliography
Defines the performance requirements and the test methods for type testing of cable accessories for use with power distribution cables of rated voltage 0,6/1,0 (1,2) kV as defined in HD 603 or other relevant cable standards.
Committee |
GEL/20/11
|
DevelopmentNote |
Together with BS 7888-4.1(2006), BS 7888-4.2(2006) and BS EN 61442 it supersedes BS 7888-1(1998) and BS 7888-2(1998). Supersedes BS 7888-3(1998) and 03/310347 DC. (08/2006) Together with BS 7933-1(2007) and BS 7933-2(2007), supersedes BS 6910-1(1988). (03/2008) 2006 Edition with it's corrigendum remains active & will be withdrawn on 08/12/2017. Supersedes 12/30262193 DC. (02/2015)
|
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard details the performance requirements and the test methods for type testing of cable accessories for use with power distribution cables of rated voltage 0,6/1,0 (1,2) kV as defined in HD 603 or other relevant cable standards. Cable accessories covered by this European Standard include joints, stop ends and outdoor terminations for extruded solid dielectric insulated cables and transition joints between extruded solid dielectric insulated and impregnated paper insulated cables. Joints, stop ends and outdoor terminations for impregnated paper insulated cables are not included. The service operating conditions of accessories should be compatible with the service operating conditions of cables on which they are to be installed. Accessories for special applications such as submarine, shipboard, explosive or seismic environments, or where specified fire performance characteristics are required, are not included. NOTE1 This European Standard does not invalidate existing approvals of products achieved on the basis of national standards and specifications and/or the demonstration of satisfactory service performance. However, products approved according to such national standards or specifications cannot directly claim approval to this European standard. NOTE2 It may be possible, subject to agreement between supplier and purchaser, and/or the relevant conformity assessment body, to demonstrate that conformity to the earlier standard can be used to claim conformity to this European Standard, provided an assessment is made of any additional type testing that may need to be carried out. Any such additional testing that is part of a sequence of testing cannot be done separately.
Standards | Relationship |
NEN EN 50393 : 2015 | Identical |
NBN EN 50393 : 2015 | Identical |
NF EN 50393 : 2015 | Identical |
I.S. EN 50393:2015 | Identical |
DIN EN 50393:2015-10 | Identical |
EN 50393:2015 | Identical |
UNE-EN 50393:2015 | Identical |
SN EN 50393:2015 | Identical |
BS 7889:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000 V, for fixed installations |
BS 7846:2015 | Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
15/30301501 DC : 0 | BS 5467 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, FOR FIXED INSTALLATIONS - SPECIFICATION |
12/30244462 DC : 0 | BS 8573 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS, HAVING LOW EMISSIONS OF SMOKE AND CORROSIVE WHEN AFFECTED BY FIRE |
BS 6724:2016 | Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
15/30301742 DC : 0 | BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS |
ENA ER G81-2 : ISSUE 2 2016 | FRAMEWORK FOR NEW LOW VOLTAGE HOUSING DEVELOPMENT INSTALLATIONS - PART 2: MATERIALS SPECIFICATION |
BS 5467:2016 | Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations. Specification |
15/30301443 DC : 0 | BS 6724 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1 900/3300 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION |
12/30244369 DC : 0 | BS 7889 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS |
BS 8573:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire |
ENA ER G81-5 : ISSUE 2 2016 | FRAMEWORK FOR NEW INDUSTRIAL AND COMMERCIAL UNDERGROUND CONNECTIONS - PART 5: MATERIALS SPECIFICATION |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60684-2:2011 | Flexible insulating sleeving - Part 2: Methods of test |
EN 61238-1:2003 | Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV) - Part 1: Test methods and requirements |
EN 60684-2:2011 | Flexible insulating sleeving - Part 2: Methods of test |
IEC 60055-2:1981 | Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables). Part 2: General and construction requirements |
IEC 60455-3-8:2013 | Resin based reactive compounds used for electrical insulation - Part 3: Specifications for individual materials - Sheet 8: Resins for cable accessories |
IEC 60684-1:2003 | Flexible insulating sleeving - Part 1: Definitions and general requirements |
EN 60684-3-247:2011/A1:2017 | FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATIONS FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 247: HEAT-SHRINKABLE POLYOLEFIN SLEEVING, DUAL WALL, NOT FLAME RETARDED, THICK AND MEDIUM WALL (IEC 60684-3-247:2011/A1:2016) |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
HD 603 S1:1994/A3:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
EN 60455-3-8:2013 | Resin based reactive compounds used for electrical insulation - Part 3: Specifications for individual materials - Sheet 8: Resins for cable accessories |
EN 60684-1:2003 | Flexible insulating sleeving - Part 1: Definitions and general requirements |
IEC 61238-1:2003 | Compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV) - Part 1: Test methods and requirements |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
IEC 60684-3-247:2011+AMD1:2016 CSV | Flexible insulating sleeving - Part 3 Specifications for individual types of sleeving - Sheet 247: Heatshrinkable, polyolefin sleeving, dual wall, not flame retarded, thick and medium wall |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
EN 61180-1:1994 | High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.