BS EN 50272-2:2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Safety requirements for secondary batteries and battery installations Stationary batteries
Hardcopy , PDF
25-05-2018
English
15-09-2001
1 Scope
2 Main applications
3 Normative references
4 General definitions
5 Protection against electric shock
6 Disconnection and separation
7 Prevention of short circuits and protection from other
effects of electric current
8 Provisions against explosion hazards
9 Provision against electrolyte hazard
10 Accommodation, housing
11 Charge current requirements
12 Identification labels, warning notices and instructions
for use, installation and maintenance
13 Transportation, storage, disposal and environmental
aspects
14 Inspection and monitoring
Annex A (informative) Charging methods, modes of operation
Annex B (informative) Calculation of safety distance to
protect against explosion hazards
Applicable to stationary secondary batteries and battery installations with a maximum voltage of DC 1500 V (nominal) and describes the principal measures for protections against hazards generated from: - electricity, - gas emission, - electrolyte. Provides requirements on safety aspects associated with the erection, use, inspection, maintenance and disposal. Covers lead-acid and NiCd batteries.
Committee |
PEL/21
|
DevelopmentNote |
Supersedes 97/201891 DC and 96/206859 DC. (03/2005)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This European Standard applies to stationary secondary batteries and battery installations with a maximum voltage of DC 1500 V (nominal) and describes the principal measures for protections against hazards generated from: - electricity, - gas emission, - electrolyte. It provides requirements on safety aspects associated with the erection, use, inspection, maintenance and disposal. It covers lead-acid and NiCd batteries.
Standards | Relationship |
I.S. EN 50272-2:2001 | Identical |
SN EN 50272-2 : 2001 | Identical |
UNE-EN 50272-2:2002 | Identical |
EN 50272-2:2001 | Identical |
NF EN 50272-2 : 2005 | Identical |
NBN EN 50272-2 : 2001 | Identical |
NEN EN 50272-2 : 2001 | Identical |
DIN EN 50272-2 : 2001 | Identical |
BS 8450:2006 | Code of practice for installation of electrical and electronic equipment in ships |
TR 102 530 : 1.2.1 | ENVIRONMENTAL ENGINEERING (EE); THE REDUCTION OF ENERGY CONSUMPTION IN TELECOMMUNICATIONS EQUIPMENT AND RELATED INFRASTRUCTURE |
12/30258581 DC : 0 | BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS |
BIP 2081 : 2012 | A GUIDE TO EMERGENCY LIGHTING |
BS 5908-2:2012 | Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations |
HD 384.4.41 S2:1996/A1:2002 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 41: PROTECTION AGAINST ELECTRIC SHOCK |
EN 60623:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells |
HD 366 : 200S1 | CLASSIFICATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT WITH REGARD TO PROTECTION AGAINST ELECTRIC SHOCK |
EN 61660-2:1997 | Short-circuit currents in d.c. auxiliary installations in power plants and substations - Part 2: Calculation of effects |
EN 60950:2000/corrigendum:2002 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT |
HD 384.7.706 : 200S1 | ELECTRICAL INSTALLATIONS OF BUILDINGS - REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATION - RESTRICTIVE CONDUCTING LOCATIONS |
HD 625.1 : 200S1 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PRINCIPLES, REQUIREMENTS AND TESTS |
IEC 60050-486:1991 | International Electrotechnical Vocabulary (IEV) - Part 486: Secondary cells and batteries |
EN 60896-1:1991/A2:1992 | STATIONARY LEAD-ACID BATTERIES - GENERAL REQUIREMENTS AND METHODS OF TEST - VENTED TYPES |
EN 50178:1997 | Electronic equipment for use in power installations |
HD 384.4.43 : 200S2 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PROTECTION FOR SAFETY - CHAPTER 43: PROTECTION AGAINST OVERCURRENT |
EN 166:2001 | Personal eye-protection - Specifications |
EN 61660-1:1997 | Short-circuit currents in d.c. auxiliary installations in power plants and substations - Part 1: Calculation of short-circuit currents |
IEC 61340-4-1:2003+AMD1:2015 CSV | Electrostatics - Part 4-1: Standard test methods for specific applications - Electrical resistance of floor coverings and installed floors |
EN 50091-1-2 : 98 COR 1 99 | |
EN 60079-10:2003 | Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas |
HD 384.5.54 : 200S1 | ELECTRICAL INSTALLATION OF BUILDINGS - SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
HD 193 : 200S2 | VOLTAGE BANDS FOR ELECTRICAL INSTALLATIONS OF BUILDINGS |
EN 60900:2012 | LIVE WORKING - HAND TOOLS FOR USE UP TO 1000 V A.C. AND 1500 V D.C. (IEC 60900:2012) |
EN 345:1992/A1:1997 | SPECIFICATION FOR SAFETY FOOTWEAR FOR PROFESSIONAL USE |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO 3864:1984 | Safety colours and safety signs |
EN 60990:2016 | Methods of measurement of touch current and protective conductor current |
EN 60896-2:1996 | Stationary lead-acid batteries - General requirements and methods of test - Part 2: Valve regulated types |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.