BS EN 50165:1997
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Electrical equipment of non-electric appliances for household and similar purposes. Safety requirements
Hardcopy , PDF
01-04-2009
English
15-09-2001
Foreword
1 Scope
2 Definitions
3 General requirement
4 General conditions for the tests
5 Void
6 Classification
7 Marking and instructions
8 Protection against access to live parts
9 Starting of motor-operated appliances
10 Power input and current
11 Heating
12 Void
13 Leakage current and electric strength at operating
temperature
14 Void
15 Moisture resistance
16 Leakage current and electric strength
17 Overload protection of transformers and associated
circuits
18 Endurance
19 Abnormal operation
20 Stability and mechanical hazards
21 Mechanical strength
22 Construction
23 Internal wiring
24 Components
25 Supply connection and external flexible cords
26 Terminals for external conductors
27 Provision for earthing
28 Screws and connections
29 Creepage distances, clearances and distances through
insulation
30 Resistance to heat, fire and tracking
31 Resistance to rusting
32 Radiation, toxicity and similar hazards
Figures
Annex A (normative) Normative references
Annex AA (informative) Standards for non electric appliances
Annex BB (informative) Standards for control and safety
devices
Safety of electrical equipment of non-electric appliances for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 48 V for other appliances.
Committee |
W/-
|
DevelopmentNote |
Supersedes 93/215323 DC (08/2001)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NBN EN 50165 : 98 AMD 1 2001 | Identical |
I.S. EN 50165:1998 | Identical |
NF EN 50165 : 97 AMD 1 2001 | Identical |
SN EN 50165 : 1997 AMD 1 2001 | Identical |
DIN EN 50165 : 2001 | Identical |
NEN EN 50165 : 97 AMD 1 2001 | Identical |
EN 50165 : 97 AMD 1 2001 | Identical |
BS 7977-2:2003 | Specification for safety and rational use of energy of domestic gas appliances Combined appliances. Gas fire/back boiler |
BS 7977-1:2002 | Specification for safety and rational use of energy of domestic gas appliances Radiant/convectors |
08/30166387 DC : DRAFT MAY 2008 | BS 7977-1 - SPECIFICATION FOR SAFETY AND RATIONAL USE OF ENERGY OF DOMESTIC GAS APPLIANCES - PART 1: RADIANT/CONVECTORS |
EN 60255-23:1996 | Electrical relays - Part 23: Contact performance |
EN 264 : 1991 | SAFETY SHUT OFF DEVICES FOR COMBUSTION PLANTS USING LIQUID FUELS - SAFETY REQUIREMENTS AND TESTING |
PREN 676 : DRAFT 2012 | FORCED DRAUGHT BURNERS FOR GASEOUS FUELS |
PREN 1643 : DRAFT 2012 | VALVE PROVING SYSTEMS FOR AUTOMATIC SHUT-OFF VALVES FOR GAS BURNERS AND GAS APPLIANCES |
EN 677:1998 | Gas-fired central heating boilers - Specific requirements for condensing boilers with a nominal heat input not exceeding 70 kW |
EN 60730-2-7:2010/AC:2011 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-7: PARTICULAR REQUIREMENTS FOR TIMERS AND TIME SWITCHES (IEC 60730-2-7:2008, MODIFIED) |
EN 60730-2-6:2016 | Automatic electrical controls - Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements |
PREN 498 : DRAFT 2009 | SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - BARBECUES FOR OUTDOOR USE CONTACT GRILLS INCLUDED |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
PREN 89 : DRAFT 2012 | GAS-FIRED STORAGE WATER HEATERS FOR THE PRODUCTION OF DOMESTIC HOT WATER |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 60730-2-9:2010 | Automatic electrical controls for household and similar use - Part 2-9: Particular requirements for temperature sensing controls |
ENV 1954 : DRAFT 1996 | INTERNAL AND EXTERNAL FAULT BEHAVIOUR OF SAFETY RELATED ELECTRONIC PARTS OF GAS APPLIANCES |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 116000-1 : 1996 | GENERIC SPECIFICATION: ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - GENERAL |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 161:2011+A3:2013 | Automatic shut-off valves for gas burners and gas appliances |
EN 267:2009+A1:2011 | Automatic forced draught burners for liquid fuels |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 125:2010+A1:2015 | Flame supervision devices for gas burning appliances - Thermoelectric flame supervision devices |
EN 60730-2-8:2002/A1:2003 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-8: PARTICULAR REQUIREMENTS FOR ELECTRICALLY OPERATED WIRE VALVES, INCLUDING MECHANICAL REQUIREMENTS |
EN 126:2012 | Multifunctional controls for gas burning appliances |
IEC 60255-1-00:1975 | Electrical relays. All-or-nothing electrical relays. *Note.-This publication supersedes IEC 255-1 (1967) and 255-2 (1969) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 230:2005 | Automatic burner control systems for oil burners |
EN 30:1979/A3 MOD.2:1985 | DOMESTIC COOKING APPLIANCES BURNING GAS |
EN 60730-2-1 : 97 AMD 11 2005 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-1: PARTICULAR REQUIREMENTS FOR ELECTRICAL CONTROLS FOR ELECTRICAL HOUSEHOLD APPLIANCES |
EN 26:2015 | Gas-fired instantaneous water heaters for the production of domestic hot water |
EN 60730-2-11:2008 | Automatic electrical controls for household and similar use - Part 2-11: Particular requirements for energy regulators |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 60730-2-5:2015 | Automatic electrical controls - Part 2-5: Particular requirements for automatic electrical burner control systems |
IEC 60255-23:1994 | Electrical relays - Part 23: Contact performance |
EN 298:2012 | Automatic burner control systems for burners and appliances burning gaseous or liquid fuels |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 60255-1-00 : 1997 | ALL-OR-NOTHING ELECTRICAL RELAYS |
PREN 303-5 : DRAFT 2010 | CENTRAL-HEATING BOILERS - PART 5: HEATING BOILERS FOR SOLID FUELS, HAND AND AUTOMATICALLY STOKED, NOMINAL HEAT OUTPUT OF UP TO 500 KW - TERMINOLOGY, REQUIREMENTS, TESTING AND MARKING |
PREN 484 : DRAFT 2015 | SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - INDEPENDENT STOVES, INCLUDING THOSE INCORPORATING A GRILL FOR OUTDOOR USE |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
BS EN 60335-1 : 2012 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
EN 625:1995 | Gas-fired central heating boilers - Specific requirements for the domestic hot water operation of combination boilers of nominal heat input not exceeding 70 kW |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.