BS EN 50132-7:2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Alarm systems. CCTV surveillance systems for use in security applications Application guidelines
Hardcopy , PDF
31-07-2015
English
31-08-2013
Foreword
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 General considerations
5 Operational requirements specifications
6 Equipment selection and performance
7 Image presentation
8 Transmission
9 Video performance characteristics
10 Storage characteristics
11 Image storage and export
12 CCTV control room configuration
13 Define test plan
14 Summary of documentation - Pre-installation
15 System installation and commissioning
16 Final documentation
17 Maintenance
Annex A (informative) - Current video standard formats
Annex B (normative) - Test protocol for CCTV target
Annex C (normative) - Test method of image quality
Guidance for the use of the video test target
Annex D (informative) - Guide to specifying CCTV
parameters
Annex E (normative) - Detection response testing and
acceptability criteria
Bibliography
Provides recommendations and requirements for the selection, planning, installation, commissioning, maintaining and testing of CCTV systems comprising of image capture device(s), interconnection(s) and image handling device(s), for use in security applications.
Committee |
GW/1/10
|
DevelopmentNote |
Supersedes 95/520771 DC. (09/2005) Supersedes 11/30202599 DC. (08/2013) Superseded by BS EN 62676-4, but remains current and will be withdrawn on 13/04/2018. (07/2015)
|
DocumentType |
Standard
|
Pages |
68
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This European Standard gives recommendations and requirements for the selection, planning, installation, commissioning, maintaining and testing of CCTV systems comprising of image capture device(s), interconnection(s) and image handling device(s), for use in security applications. The objectives of this standard are to: provide a framework to assist customers, installers and users in establishing their requirements, assist specifiers and users in determining the appropriate equipment required for a given application, provide means of evaluating objectively the performance of the CCTV system.
Standards | Relationship |
DIN EN 50132-7 : 2013 | Identical |
I.S. EN 50132-7:2012 | Identical |
SN EN 50132-7 : 1996 | Identical |
NEN EN 50132-7 : 2012 | Identical |
NF EN 50132-7 : 2012 | Identical |
NBN EN 50132-7 : 2012 | Identical |
EN 50132-7:2012 | Identical |
UNE-EN 50132-7:2013 | Identical |
09/30181219 DC : 0 | BS 8418 - INSTALLATION AND REMOTE MONITORING OF DETECTOR-ACTIVATED CCTV SYSTEMS - CODE OF PRACTICE |
BS 5979:2007 | Remote centres receiving signals from fire and security systems. Code of practice |
BS 8220-1:2000 | Guide for security of buildings against crime Dwellings |
BS 5979:2000 | Code of practice for remote centres receiving signals from security systems |
BS DD254(2001) : 2001 | CRIME REDUCTION MEASURES FOR HOLIDAY RESORTS AND ACCOMMODATION - GUIDANCE AND RECOMMENDATIONS |
BS PAS 38(2000) : 2000 | INSTALLATION AND REMOTE MONITORING OF DETECTOR ACTIVATED CCTV SYSTEMS - CODE OF PRACTICE |
02/700084 DC : DRAFT JAN 2002 | BS 8418 - INSTALLATION AND REMOTE MONITORING OF DETECTOR ACTIVATED CCTV SYSTEMS - CODE OF PRACTICE |
06/30133574 DC : DRAFT DEC 2006 | BS 5979 - CODE OF PRACTICE FOR REMOTE CENTRES RECEIVING SIGNALS FROM SECURITY SYSTEMS |
BS 8495:2007 | Code of practice for digital CCTV recording systems for the purpose of image export to be used as evidence |
BS 8418:2003 | Installation and remote monitoring of detector activated CCTV systems. Code of practice |
BS 8418:2010 | Installation and remote monitoring of detector-activated CCTV systems. Code of practice |
EN 50132-5-2 : 2011 COR 2012 | ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 5-2: IP VIDEO TRANSMISSION PROTOCOLS |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
EN 50132-1 : 2010 COR 2010 | ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS |
EN 50132-5-1 : 2011 COR 2012 | ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 5-1: VIDEO TRANSMISSION - GENERAL VIDEO TRANSMISSION PERFORMANCE REQUIREMENTS |
ISO 31000:2009 | Risk management Principles and guidelines |
EN 62305-3:2011 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
CLC/TS 50398:2009 | Alarm systems - Combined and integrated alarm systems - General requirements |
EN 50310:2016 | Telecommunications bonding networks for buildings and other structures |
EN 50132-5-3:2012 | Alarm systems - CCTV surveillance systems for use in security applications - Part 5-3: Video transmission - Analogue and digital video transmission |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.