• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 50131-3:2009

Current

Current

The latest, up-to-date edition.

Alarm systems. Intrusion and hold-up systems Control and indicating equipment

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-04-2009

£280.00
Excluding VAT

Introduction
1 Scope
2 Normative references
3 Definitions and abbreviations
   3.1 Definitions
   3.2 Abbreviations
4 Equipment attributes
   4.1 General
   4.2 Functionality
5 CIE construction
6 Security grade
7 Environmental performance
   7.1 Requirements
   7.2 Environmental and EMC tests
8 Functional requirements
   8.1 Inputs
   8.2 Outputs
   8.3 Operation
   8.4 Processing
   8.5 Indication
   8.6 Notification outputs
   8.7 Tamper security (detection/protection)
   8.8 Interconnections
   8.9 Timing
   8.10 Event recording
   8.11 Power supply
9 Product documentation
   9.1 Installation and maintenance
   9.2 Operating instructions
10 Marking and labelling
11 Tests
   11.1 Test conditions
   11.2 Test procedures
   11.3 Reduced functional test
   11.4 Functional tests
   11.5 Access level
   11.6 Authorization requirements
   11.7 Operational tests
   11.8 Tamper security tests
   11.9 Substitution tests
   11.10 Testing of I&HAS timing performance
   11.11 Testing for interconnections
   11.12 Event log
   11.13 Marking and documentation
   11.14 Environmental and EMC tests
Annex A (informative) - Interconnection types
Annex B (informative) - Summary of timing requirements
Annex C (normative) - Use of non-I&HAS interface
Annex D (informative) - Summary of function cross
        references
Bibliography

Describes the requirements, performance criteria and testing procedures for control and indicating equipment (CIE) intended for use in intrusion and hold-up alarm systems (I&HAS) installed in buildings.

Committee
GW/1/1
DevelopmentNote
Supersedes DD CLC/TS 50131-3 & 08/30177443 DC. (04/2009)
DocumentType
Standard
Pages
78
PublisherName
British Standards Institution
Status
Current
Supersedes
UnderRevision

This standard specifies the requirements, performance criteria and testing procedures for control and indicating equipment (CIE) intended for use in intrusion and hold-up alarm systems (I&HAS) installed in buildings. This document also applies to CIE to be used in IAS or HAS. The CIE may incorporate processing functions of other I&HAS components or its processing requirements may be distributed among such components. This standard specifies the requirements for CIE installed in buildings using specific or non-specific wired interconnections or wire-free interconnections. These requirements also apply to ACE that are installed inside or outside of the supervised premises and mounted in indoor or outdoor environments. Where CIE shares means of detection, interconnection, control, communication, processing and/or power supplies with other applications, these requirements apply to I&HAS functions only. This standard specifies performance requirements for CIE at each of the four security grades identified in the European Standard EN 50131-1, “Alarm Systems – Intrusion and hold-up systems – System requirements”. Requirements are also specified for four environmental classes covering applications for indoor and outdoor locations. This standard includes mandatory functions, which shall be provided on all CIE for the appropriate security grade, as well as optional functions that may additionally be provided. This standard does not deal with requirements for compliance with EU regulatory Directives, such as the EMC Directive, Low Voltage Directive, etc. except in that it specifies the equipment operating conditions for EMC susceptibility testing as required by EN 50130-4. NOTE In this standard reference to the term “I&HAS” is used throughout, except where there is specific need to differentiate between the IAS and HAS portions of a system. The term is intended to include IAS and HAS when such systems are installed separately.

Standards Relationship
EN 50131-3:2009 Identical
IEC 62148-18:2014 Identical

PD 6662:2010 Scheme for the application of European standards for intrusion and hold-up alarm systems
PD 6662:2017 Scheme for the application of European Standards for intrusion and hold-up alarm systems
16/30338904 DC : 0 BS 9263 - INTRUDER AND HOLD-UP ALARM SYSTEMS - COMMISSIONING, MAINTENANCE AND REMOTE SUPPORT - CODE OF PRACTICE
09/30203716 DC : 0 PD 6662 - SCHEME FOR THE APPLICATION OF EUROPEAN STANDARDS FOR INTRUSION AND HOLD-UP ALARM SYSTEMS
BS 8243(2010) : 2010 INSTALLATION AND CONFIGURATION OF INTRUDER AND HOLD-UP ALARM SYSTEMS DESIGNED TO GENERATE CONFIRMED ALARM CONDITIONS - CODE OF PRACTICE

EN 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
CLC/TS 50398:2009 Alarm systems - Combined and integrated alarm systems - General requirements
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
EN 50131-6:2017 Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 50131-5-3:2017 Alarm systems - Intrusion systems - Part 5-3: Requirements for interconnections equipment using radio frequency techniques
EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.