BS EN 50124-1:2017
Current
The latest, up-to-date edition.
Railway applications. Insulation coordination Basic requirements. Clearances and creepage distances for all electrical and electronic equipment
Hardcopy , PDF
English
31-03-2017
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Basis for insulation coordination
5 Requirements and dimensioning rules for clearances
6 Dimensioning rules for creepage distances
7 Tests and measurements
8 Specific requirements for applications in the
railway field
Annex A (normative) - Tables
Annex B (normative) - Provisions for type and routine
dielectric tests for equipment
Annex C (normative) - Methods of measuring creepage
distances and clearances
Annex D (normative) - Correlation between U[n] and U[Nm]
Annex E (informative) - Macro-environmental conditions
Annex F (informative) - Application guide
Annex ZZ (informative) Relationship between this
European Standard and the Essential
Requirements of EU Directive 2008/57/EC
Bibliography
Defines insulation coordination in railways. Pertains to equipment for use in signalling, rolling stock and fixed installations.
Committee |
GEL/9
|
DevelopmentNote |
Supersedes 93/209659 DC (01/2004) Supersedes 15/30298489 DC. (03/2017)
|
DocumentType |
Standard
|
Pages |
58
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard deals with insulation coordination in railways. It applies to equipment for use in signalling, rolling stock and fixed installations. Insulation coordination is concerned with the selection, dimensioning and correlation of insulation both within and between items of equipment. In dimensioning insulation, electrical stresses and environmental conditions are taken into account. For the same conditions and stresses, these dimensions are the same. An objective of insulation coordination is to avoid unnecessary over dimensioning of insulation. This standard specifies: requirements for clearances and creepage distances for equipment; general requirements for tests pertaining to insulation coordination. The term equipment relates to a section as defined in 3.3 it may apply to a system, a sub-system, an apparatus, a part of an apparatus, or a physical realization of an equipotential line. This standard does not deal with: distances through solid or liquid insulation; distances through gases other than air; distances through air not at atmospheric pressure; equipment used under extreme conditions. Product standards should align with this generic standard. However, they may require, with justification, different requirements due to safety and/or reliability reasons, e.g. for signalling, and/or particular operating conditions of the equipment itself, e.g. overhead contact lines which should comply with EN50119 . This standard also gives provisions for dielectric tests (type tests or routine tests) on equipment (see AnnexB). NOTE For safety critical systems, specific requirements are needed. These requirements are given in the product specific signalling standard EN50129 .
Standards | Relationship |
I.S. EN 50124-1:2017 | Identical |
SN EN 50124-1 : 2017 | Identical |
NF EN 50124-1 : 2017 | Identical |
EN 50124-1:2017 | Identical |
NEN EN 50124-1 : 2017 | Identical |
NBN EN 50124-1 : 2001 AMD 2 2006 | Identical |
UNE-EN 50124-1:2001 | Identical |
DIN EN 50124-1 : 2017 | Identical |
UNE-EN 50124-1:2017 | Identical |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 61936-1:2010+AMD1:2014 CSV | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60383-1:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria |
EN 50153 : 2014 AMD 1 2017 | RAILWAY APPLICATIONS - ROLLING STOCK - PROTECTIVE PROVISIONS RELATING TO ELECTRICAL HAZARDS |
IEC 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
IEC 60660:1999 | Insulators - Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 000 V up to but not including 300 kV |
2008/57/EC : 2008 AMD 5 2014 | DIRECTIVE 2008/1957/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 17 JUNE 2008 ON THE INTEROPERABILITY OF THE RAIL SYSTEM WITHIN THE COMMUNITY (RECAST) (TEXT WITH EEA RELEVANCE) |
EN 60660:1999 | Insulators - Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 kV up to but not including 300 kV |
EN 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
EN 60383-1:1996/A11:1999 | INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC OR GLASS INSULATOR UNITS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
EN 60099-1:1994/A1:1999 | SURGE ARRESTERS - PART 1: NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTERS FOR A.C. SYSTEMS |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
EN 60587:2007 | Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
EN 60507:2014 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
EN 61936-1 : 2010 AMD 1 2014 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014) |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 50129 : 2003 COR 2010 | RAILWAY APPLICATIONS - COMMUNICATION, SIGNALLING AND PROCESSING SYSTEMS - SAFETY RELATED ELECTRONIC SYSTEMS FOR SIGNALLING |
IEC 60099-1:1991+AMD1:1999 CSV | Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC 60664-5:2007 | Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
EN 60071-2:1997 | Insulation co-ordination - Part 2: Application guide |
EN 60168:1994/A2:2000 | TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1KV |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 60587:2007 | Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion |
EN 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
EN 60664-5:2007 | Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 60077-1:2017 | Railway applications - Electric equipment for rolling stock - Part 1: General service conditions and general rules |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60664-3:2017 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 60383-2:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria |
EN 60383-2:1995 | Insulators for overhead lines with a nominal voltage above 1 kV - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria |
IEC 60168:1994+AMD1:1997+AMD2:2000 CSV | Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.