• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 16905-5:2017

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Gas-fired endothermic engine driven heat pumps Calculation of seasonal performances in heating and cooling mode

Available format(s)

Hardcopy , PDF

Superseded date

20-01-2023

Superseded by

BS EN 16905-5:2022

Language(s)

English

Published date

31-03-2017

£260.00
Excluding VAT

European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Part load conditions in cooling mode
5 Part load conditions in heating mode
6 Calculation methods for reference SPER[c]
7 Calculation methods for reference SPER[h]
Annex A (normative) - Determination of reference
        annual cooling/heating demands and
        determination of hours for active mode,
        thermostat off, standby, off mode and
        crankcase heater mode for reference
        SAEF[C] and SAEF[h] calculation
Annex B (informative) - Calculation example for
        reference SGUE[c], SAEF[c],
        SEHREgas[c], SEHREelec[c] and SPER[c]
Annex C (informative) - Calculation example for
        reference SGUE[h], SAEF[h], SEHREgas[h],
        SEHREelec[h] and SPER[h]
Annex D (informative) - Adaption of water temperature
        for fixed capacity
Annex E (informative) - Compensation method for air
        to water and water to water units
Annex ZA (informative) - Relationship between this
         European Standard and the ecodesign
         requirements of Commission Regulation
         (EU) No 813/2013 aimed to be covered
Annex ZB (informative) - Relationship between this
         European Standard and the energy
         labelling requirements of Commission
         Delegated Regulation (EU) No 811/2013
         aimed to be covered
Bibliography

Defines the requirements, test methods and test conditions for the rating and performance calculation of air conditioners and heat pumps using either air, water or brine as heat transfer media, with gas-fired endothermic engine driven compressors when used for space heating, cooling and refrigeration, hereafter referred to as 'GEHP appliance'.

Committee
GSE/37
DevelopmentNote
Supersedes 15/30326266 DC. (03/2017)
DocumentType
Standard
Pages
62
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

1.1 Scope of EN 16905 series This European Standard specifies the requirements, test methods and test conditions for the rating and performance calculation of air conditioners and heat pumps using either air, water or brine as heat transfer media, with gas-fired endothermic engine driven compressors when used for space heating, cooling and refrigeration, hereafter referred to as “GEHP appliance??. This European Standard only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions. This European Standard only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437. This European Standard only applies to appliances having: gas fired endothermic engines under the control of fully automatic control systems; closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated; where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation; where the maximum operating pressure in the: heating water circuit (if installed) does not exceed 6 bar, domestic hot water circuit (if installed) does not exceed 10 bar. This European Standard applies to appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery. The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by this European Standard. Packaged units, single split and multisplit systems are covered by this European Standard. Single duct and double duct units are covered by this European Standard. The above appliances can have one or more primary or secondary functions. This European Standard is applicable to appliances that are intended to be type tested. Requirements for appliances that are not type tested would need to be subject to further consideration. In the case of packaged units (consisting of several parts), this European Standard applies only to those designed and supplied as a complete package. NOTE All the symbols given in this text are used regardless of the language used. 1.2 Scope of EN 16905-5 This part of the EN 16905 series specifies the calculation of seasonal performance factor for gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery.

Standards Relationship
EN 16905-5:2017 Identical

EN 12309-1:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 1: Terms and definitions
EN 16905-3:2017 Gas-fired endothermic engine driven heat pumps - Part 3: Test conditions
EN 12309-4:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 4: Test methods
EN 16905-4:2017 Gas-fired endothermic engine driven heat pumps - Part 4: Test methods
EN 14825:2016 Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling - Testing and rating at part load conditions and calculation of seasonal performance
EN 437:2003+A1:2009 Test gases - Test pressures - Appliance categories
EN 16905-1:2017 Gas-fired endothermic engine driven heat pumps - Part 1: Terms and definitions
EN 12309-5:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 5: Requirements
EN 12309-3:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 3: Test conditions

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.