BS EN 15456:2008
Current
The latest, up-to-date edition.
Heating boilers. Electrical power consumption for heat generators. System boundaries. Measurements
30-05-2008
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 System boundaries for measurements
4.1 General
4.2 System with circulator (pump) for heat generation
4.3 System with a single circulator (pump) for heat
generation and heat distribution
4.4 System without any circulator (pump)
4.5 Burner
5 Measurement
5.1 Heating boiler
5.1.1 Setting of the heating boiler
5.1.2 Determination of the water side resistance
5.1.3 Measurement modes
5.2 Forced-draught burners
5.3 Pellet burner
5.4 Oil stoves
5.5 Determination of the water side resistance
5.6 Test report and documentation
Annex A (normative) - Test report
A.1 Summary
A.2 Testing the electrical power consumption P[aux]
Annex B (informative) - Determination of the water side
resistance
B.1 Operating conditions
B.1.1 General
B.1.2 Boilers without integrated pump
B.1.3 Boilers with integrated pump
B.1.4 Determination of operating conditions of
boilers with integrated pump
Bibliography
Defines heating boilers and burners equipped with a fan including all components specified by the manufacturer to be required for the designed boiler operation.
Committee |
RHE/24
|
DevelopmentNote |
Supersedes 06/30145467 DC. (05/2008)
|
DocumentType |
Standard
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard applies to heating boilers (e.g. with forced-draught burners (unit)) and burners equipped with a fan including all components specified by the manufacturer to be required for the designed boiler operation. This European Standard also applies to heating boilers sold without burners. This European Standard covers the required definitions, the system boundaries, the measurements for the determination of the electrical power consumption and, where applicable, the water side resistance in order to establish the electric auxiliary energy for: ? Oil-fired forced-draught burners in accordance with EN 267; ? Automatic forced-draught burners for gaseous fuels in accordance with EN 676; ? Flued oil stoves with vaporizing burners in accordance with EN 1; ? Heating boilers sold without burners for: ? Oil-fired forced-draught burners in accordance with EN 303-1 [6], EN 303-2 [7] and EN 304; ? Condensing boilers for liquid fuels in accordance with EN 15034; ? Room sealed boilers for fuel oil in accordance with EN 15035; ? Heating boilers - Heating boilers with forced-draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C in accordance with EN 14394; ? Pellet burners for small heating boilers in accordance with EN 15270. NOTE All measurements for boilers are carried out in the heating mode only. For hot water production this mode is also relevant.
Standards | Relationship |
EN 15456:2008 | Identical |
EN 15270:2007 | Pellet burners for small heating boilers - Definitions, requirements, testing, marking |
EN 14394:2005+A1:2008 | Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C |
PREN 15316-4-1 : DRAFT 2014 | HEATING SYSTEMS AND WATER BASED COOLING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS) |
EN 304:2017 | Heating boilers - Test code for heating boilers for atomizing oil burners |
PREN 15502-1 : DRAFT 2010 | GAS-FIRED HEATING BOILERS - PART 1: GENERAL REQUIREMENTS AND TESTS |
EN 303-1:2017 | Heating boilers - Part 1: Heating boilers with forced draught burners - Terminology, general requirements, testing and marking |
EN 267:2009+A1:2011 | Automatic forced draught burners for liquid fuels |
EN 303-2:2017 | Heating boilers - Part 2: Heating boilers with forced draught burners - Special requirements for boilers with atomizing oil burners |
EN 437:2003+A1:2009 | Test gases - Test pressures - Appliance categories |
92/42/EEC : 1992 AMD 5 2013 | COUNCIL DIRECTIVE 92/42/EEC OF 21 MAY 1992 ON EFFICIENCY REQUIREMENTS FOR NEW HOT-WATER BOILERS FIRED WITH LIQUID OR GASEOUS FUELS |
EN 15035:2006 | Heating boilers - Special requirements for oil fired room sealed units up to 70 kW |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.