BS EN 14181:2014
Current
The latest, up-to-date edition.
Stationary source emissions. Quality assurance of automated measuring systems
Hardcopy , PDF
English
30-11-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Principle
6 Calibration and validation of the
AMS (QAL2)
7 Ongoing quality assurance during
operation (QAL3)
8 Annual Surveillance Test (AST)
9 Documentation
Annex A (normative) - QAL2 and AST functional
test of AMS
Annex B (normative) - Test of linearity
Annex C (informative) - Control charts
Annex D (normative) - Documentation
Annex E (informative) - Examples of calculation of the
calibration function and of the variability test
Annex F (informative) - Example of calculation of the
standard deviation s[AMS] of the AMS at zero
and span level
Annex G (informative) - Example of using the calibration
function and testing the variability and validity of
the calibration function in the AST
Annex H (informative) - Implementation of QAL1
Annex I (normative) - k[v] and t[0,95; N-1] values
Annex J (informative) - Significant technical changes
Bibliography
Describes procedures for establishing quality assurance levels (QAL) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters.
Committee |
EH/2/1
|
DevelopmentNote |
Supersedes 01/562616 DC. (12/2004) Supersedes 12/30259213 DC. (12/2014)
|
DocumentType |
Standard
|
Pages |
88
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies procedures for establishing quality assurance levels (QAL) for automated measuring systems (AMS) installed on industrial plants for the determination of the flue gas components and other flue gas parameters. This European Standard specifies: a procedure (QAL2) to calibrate the AMS and determine the variability of the measured values obtained by it, so as to demonstrate the suitability of the AMS for its application, following its installation; a procedure (QAL3) to maintain and demonstrate the required quality of the measurement results during the normal operation of an AMS, by checking that the zero and span characteristics are consistent with those determined during QAL1; a procedure for the annual surveillance tests (AST) of the AMS in order to evaluate (i) that it functions correctly and its performance remains valid and (ii) that its calibration function and variability remain as previously determined. This European Standard is designed to be used after the AMS has been certified in accordance with the series of European Standards EN15267 .
Standards | Relationship |
UNI EN 14181 : 2005 | Identical |
DIN EN 14181:2015-02 | Identical |
SN EN 14181 : 2015 | Identical |
EN 14181:2014 | Identical |
NEN EN 14181 : 2014 | Identical |
NF EN 14181 : 2014 | Identical |
I.S. EN 14181:2014 | Identical |
NS EN 14181 : 2014 | Identical |
NBN EN 14181 : 2015 | Identical |
UNE-EN 14181:2015 | Identical |
BS 6739:2009 | Code of practice for instrumentation in process control systems: installation design and practice |
08/30136724 DC : DRAFT MAY 2008 | BS 6739 - CODE OF PRACTICE FOR INSTRUMENTATION IN PROCESS CONTROL SYSTEMS - INSTALLATION DESIGN AND PRACTICE |
EEMUA 175 : 2013 | EEMUA CODE OF PRACTICE: CALIBRATION AND VALIDATION OF PROCESS ANALYSERS |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 15267-3:2007 | Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources |
ISO 14956:2002 | Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty |
EN 15267-2:2009 | Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process |
ISO 11095:1996 | Linear calibration using reference materials |
EN 15259:2007 | Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report |
EN 13284-1:2017 | Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method |
EN 13284-2:2017 | Stationary source emissions - Determination of low range mass concentration of dust - Part 2: Quality assurance of automated measuring systems |
EN 15058:2017 | Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry |
EN ISO 14956:2002 | Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002) |
EN 15267-1:2009 | Air quality - Certification of automated measuring systems - Part 1: General principles |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
ISO 3534-1:2006 | Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability |