BS EN 14154-2 : 2005
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
WATER METERS - PART 2: INSTALLATION AND CONDITIONS OF USE
Hardcopy , PDF
30-06-2014
English
01-01-2005
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Criteria for the selection of water meters
5 Installation requirements
6 First operation of new or repaired water meters
Annex A (informative) - Concentric manifold solutions
Annex B (normative) - Connection interfaces - Solutions
for cartridge meters
Annex C (informative) - Examples of adaptors and converters
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements of
EU Directive 22/2004/EC on Measuring Instruments
Bibliography
Describes criteria for selection of water meters, installation requirements and the first operation of new or repaired meters to ensure accurate constant measurement and reliable reading of the meter.
Committee |
CPI/30/7/1
|
DevelopmentNote |
Supersedes BS ISO 4064-2, BS ISO 7858-2 and 01/122225 DC. (06/2005) 2005 Edition Re-Issued in June 2011 & incorporates AMD 2 2011. (06/2011)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NF EN 14154-2 : 2005 + A2 2012 | Identical |
NBN EN 14154-2 : 2005 + A2 2011 | Identical |
NS EN 14154-2 : 2005 + A2 2011 | Identical |
I.S. EN 14154-2:2005 | Identical |
NEN EN 14154-2 : 2005 + A2 2011 | Identical |
SN EN 14154-2 : 2005 + A2 2011 | Identical |
EN 14154-2:2005+A2:2011 | Identical |
UNI EN 14154-2 : 2011 | Identical |
UNE-EN 14154-2:2005 | Identical |
DIN EN 14154-2:2011-06 | Identical |
EN 60068-3-1:2011 | Environmental testing - Part 3-1: Supporting documentation and guidance - Cold and dry heat tests |
ISO 7005-2:1988 | Metallic flanges — Part 2: Cast iron flanges |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 14154-1:2005+A2:2011 | Water meters - Part 1: General requirements |
IEC 60068-3-1A:1978 | Environmental testing - Part 3: Background information - First supplement |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60068-3-1:2011 | Environmental testing - Part 3-1: Supporting documentation and guidance - Cold and dry heat tests |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
ISO 7005-3:1988 | Metallic flanges Part 3: Copper alloy and composite flanges |
EN 60068-2-64:2008 | ENVIRONMENTAL TESTING - PART 2-64: TESTS - TEST FH: VIBRATION, BROADBAND RANDOM AND GUIDANCE |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
ISO 3:1973 | Preferred numbers Series of preferred numbers |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 1717:2000 | Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
IEC 60068-2-64:2008 | Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN ISO 6708:1995 | Pipework components - Definition and selection of DN (nominal size) (ISO 6708:1995) |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
EN 14154-3:2005+A2:2011 | Water meters - Part 3: Test methods and equipment |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60068-2-2a:1976 | Supplement A - Basic environmental testing procedures - Part 2: Tests - Tests B: Dry heat |
EN 1333:2006 | Flanges and their joints - Pipework components - Definition and selection of PN |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60068-3-4:2001 | Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |
ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
EN 60068-2-47:2005 | Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.