BS EN 1096-1:2012
Current
The latest, up-to-date edition.
Glass in building. Coated glass Definitions and classification
Hardcopy , PDF
English
30-06-2012
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Description of additive methods of deposition
5 Glass substrates
6 Luminous, solar and thermal properties
7 Classification of coated glass
8 Appearance
9 Product information
Annex A (informative) - Example of presentation
of coated glass properties
Bibliography
Provides the characteristics, properties and classification of coated glass for use in building.
Committee |
B/520
|
DevelopmentNote |
Supersedes 93/104624 DC. (07/2005)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard defines the characteristics, properties and classification of coated glass for use in building.
Test methods and procedures used to establish durability are in Parts 2 and 3 of this standard.
Factory production control and evaluation of conformity, including Annex ZA, are in Part 4 of this standard.
Test methods for determination of self cleaning performances of coated glass are in Part 5.
This standard applies to coated glass for glazing application for use in normally occupied domestic or commercial premises.
This standard is not applicable to:
adhesive backed polymeric films on glass (prEN 15755-1);
mirrors made from silvered float glass (EN 1036-1);
enamelled glass (EN 12150-1, EN 1863-1, 14179-1).
Painted glass (standard in development)
Standards | Relationship |
UNE-EN 1096-1:2012 | Identical |
NEN EN 1096-1 : 2012 | Identical |
I.S. EN 1096-1:2012 | Identical |
EN 1096-1:2012 | Identical |
SN EN 1096-1 : 2012 | Identical |
NF EN 1096-1 : 2012 | Identical |
NBN EN 1096-1 : 2012 | Identical |
UNI EN 1096-1 : 2012 | Identical |
NS EN 1096-1 : 2012 | Identical |
DIN EN 1096-1:2012-04 | Identical |
08/30143158 DC : DRAFT AUG 2008 | BS 644 - TIMBER WINDOWS - FULLY FINISHED FACTORY ASSEMBLED WINDOWS OF VARIOUS TYPES - SPECIFICATION |
BS 6262-1:2017 | Glazing for buildings General methodology for the selection of glazing |
EN 13024-1:2011 | Glass in building - Thermally toughened borosilicate safety glass - Part 1: Definition and description |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
EN 1748-2-1:2004 | Glass in building - Special basic products - Glass ceramics - Part 2-1 Definitions and general physical and mechanical properties |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
EN 14321-1:2005 | Glass in building - Thermally toughened alkaline earth silicate safety glass - Part 1: Definition and description |
EN 14179-1:2016 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
EN 572-7:2012 | Glass in building - Basic soda lime silicate glass products - Part 7: Wired or unwired channel shaped glass |
EN 12898:2001 | Glass in building - Determination of the emissivity |
EN ISO 12543-2:2011 | Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2011) |
ISO 12543-3:2011 | Glass in building Laminated glass and laminated safety glass Part 3: Laminated glass |
EN 1863-1:2011 | Glass in building - Heat strengthened soda lime silicate glass - Part 1: Definition and description |
EN 14178-1:2004 | Glass in building - Basic alkaline earth silicate glass products - Part 1: Float glass |
EN ISO 12543-3:2011 | Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2011) |
ISO 12543-2:2011 | Glass in building Laminated glass and laminated safety glass Part 2: Laminated safety glass |
EN 572-6:2012 | Glass in building - Basic soda lime silicate glass products - Part 6: Wired patterned glass |
EN 572-2:2012 | Glass in building - Basic soda lime silicate glass products - Part 2: Float glass |
EN 12150-1:2015 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
EN 674:2011 | Glass in building - Determination of thermal transmittance (U value) - Guarded hot plate method |
EN 1748-1-1:2004 | Glass in building - Special basic products -Borosilicate glasses - Part 1-1: Definition and general physical and mechanical properties |
EN 572-4:2012 | Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass |
EN 675:2011 | Glass in building - Determination of thermal transmittance (U value) - Heat flow meter method |
EN 572-5:2012 | Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass |
EN 572-8:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 8: Supplied and final cut sizes |
EN 1096-3:2012 | Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings |
EN 1096-2:2012 | Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.