• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS 890:1972

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Specification for building limes

Available format(s)

Hardcopy , PDF

Superseded date

15-10-1995

Superseded by

BS 890:1995

Language(s)

English

Published date

13-10-1972

Co-operating organizations
Foreword
Specification
1 General
1.1 Scope
1.2 Water for testing
1.3 Certificate of test
1.4 Independent tests
1.5 Lime in tropical climates
2 Hydrated lime (powder)
2.1 Classification
2.2 Description
2.3 Size of sample and method of sampling
2.4 Composition
2.5 Physical tests
3 Quicklime
3.1 Classification
3.2 Description
3.3 Size of sample and method of sampling
3.4 Composition
3.5 Physical tests
4 Lime putty
4.1 Classification
4.2 Description
4.3 Size of sample and method of sampling
4.4 Composition
4.5 Physical tests
Appendices
A Sampling of lime
B Determination of matter insoluble in hydrochloric
     acid
C Determination of soluble salts
D Determination of soluble silica
E Determination of fineness of dry hydrated lime and
     of lime putty, and determination of water content
     of lime putty
F General expansion test for dry hydrated lime
G Determination of soundness of hydrated lime by the
     pat test
H Descriptions of standard flow-table and mould
J Preparation of lime putty of standard consistence
K Determination of density of putty and volume yield
     of lime
L Determination of workability
M Determination of hydraulic strength
N Standard method of isothermal slaking of quicklime
P Method for determination of residue on slaking
Q Test for separation of water from lime putty on
     standing
Tables
1 Chemical requirements for hydrated lime (powder)
2 Physical requirements for hydrated lime (powder)
3 Chemical requirements for quicklime
4 Physical requirements for quicklime
5 Chemical requirements for lime putty
6 Physical requirements for lime putty
Figures
1 Sampling tube
2 Sampling points for a truck of lime putty
3 Le Chatelier mould
4 Apparatus for measuring extensibility of Le
     Chatelier moulds
5 Steam cabinet for soundness tests
6 Typical trowel
7 Flow-table
8 Flow-table and conical mould
9 Typical putty density vessel

In four parts: general; hydrated lime (powder); quicklime; lime putty. Requirements for water for testing; certificate of test; independent tests; lime in tropical climates; classification, description; size of sample and method of sampling; composition, physical tests. Appendices include: matter insoluble in hydrochloric acid; soluble salts; soluble silica; fineness of dry hydrated lime and of lime putty; water content of lime putty; expansion of dry hydrated lime; soundness of hydrated lime; flow ta ble and mould, lime putty of standard consistence; density of putty and volume yield of lime; workability; hydraulic strength; isothermal slaking of quicklime; determination of residue on slaking; separation of water from lime putty on standing.

Committee
B/516
DevelopmentNote
The requirements for test methods have been replaced by Parts 1-4 of BS 6463. BS DRAFT 93/106385 DC REFERS TO A NEW REVISION
DocumentType
Standard
Pages
34
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

Standards Relationship
UNE-EN 61212-3-2:2013 Identical

BS 1722-16:1992 Fences Specification for organic powder coatings to be used as a plastics finish to components and mesh
BS 6497:1984 Specification for powder organic coatings for application and stoving to hot-dip galvanized hot-rolled steel sections and preformed steel sheet for windows and associated external architectural purposes, and for the finish on galvanized steel sections and preformed sheet coated with powder organic coatings
PD 6472:1974 Guide to specifying the quality of building mortars
BS 6461-1:1984 Installation of chimneys and flues for domestic appliances burning solid fuel (including wood and peat) Code of practice for masonry chimneys and flue pipes
BS 5385-5:1994 Wall and floor tiling Code of practice for the design and installation of terrazzo tile and slab, natural stone and composition block floorings
BS 4254:1983 Specification for two-part polysulphide-based sealants
BS 8298:1994 Code of practice for design and installation of natural stone cladding and lining
BS 3712-2:1973 Building and construction sealants Methods of test for seepage, staining, shrinkage, shelf life and paintability
BS 6457:1984 Specification for reconstructed stone masonry units

BS 1580-1&2(1962) : 1962 SPECIFICATION FOR UNIFIED SCREW THREADS - DIAMETERS 1/4 INCH AND LARGER

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.