BS 8524-1:2013
Current
The latest, up-to-date edition.
Active fire curtain barrier assemblies Specification
Hardcopy , PDF
English
30-04-2013
Foreword
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Barrier assembly design
5 Performance requirements
6 Information to be supplied with the barrier assembly
7 Marking and labelling
Annexes
Annex A (normative) - Overlapping multiple barriers
Annex B (normative) - Order of testing
Annex C (normative) - General requirements for testing
Annex D (normative) - Test method for barrier assembly
reliability and response time and the durability
of materials
Annex E (normative) - Test method for the durability and
reliability of alternative or additional motors
Annex F (normative) - Calculation of ambient temperature
smoke leakage
Annex G (normative) - Test method for reliability of motor
operation at elevated temperatures
Annex H (normative) - Test method for ancillary and optional
equipment
Annex I (informative) - Typical product performance summary
Bibliography
Defines requirements for the design, testing and classification of active fire curtain barrier assemblies, for installation in accordance with the recommendations of BS 8524-2.
Committee |
FSH/25
|
DevelopmentNote |
Supersedes 09/30189801 DC & 12/30263295 DC. (05/2013) Supersedes BS PAS 121(2007). (07/2013)
|
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of BS8524 specifies requirements for the design, testing and classification of active fire curtain barrier assemblies, for installation in accordance with the recommendations of BS8524‑2. It covers the reliability and durability, fire resistance, smoke containment and impact resistance performance of the active fire curtain barrier assemblies, their control devices and ancillary equipment.
The requirements within this part of BS8524 are applicable to active fire curtain barrier assemblies of any material that are designed to provide fire resistance.
This part of BS8524 does not cover active smoke barriers, or active fire curtain barrier assemblies that are used only for fire and smoke control as fire doors.
NOTE1 Smoke barriers, used solely for smoke control, are covered by BSEN12101‑1. Such smoke barriers are not considered to be active fire curtain barrier assemblies within the scope of BS8524.
NOTE2 Guidance on fire doors is given in BS8214. Requirements for fire doors for fire and smoke control are given in prEN16034 (currently in preparation).
BS 7346-8:2013 | Components for smoke control systems Code of practice for planning, design, installation, commissioning and maintenance |
BS 9991:2015 | Fire safety in the design, management and use of residential buildings. Code of practice |
15/30301829 DC : 0 | BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE |
BS 8524-2:2013 | Active fire curtain barrier assemblies Code of practice for application, installation and maintenance |
16/30314117 DC : 0 | BS 9999 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF BUILDINGS - CODE OF PRACTICE |
BS 5234-2:1992 | Partitions (including matching linings) Specification for performance requirements for strength and robustness including methods of test |
BS PAS 121(2007) : 2007 | SPECIFICATION FOR ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES AND ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WITH SMOKE RATING |
BS EN 13501-2 : 2007 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES |
BS ISO 21927-9:2012 | Smoke and heat control systems Specification for control equipment |
BS EN 1634-1 : 2014 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 1: FIRE RESISTANCE TEST FOR DOOR AND SHUTTER ASSEMBLIES AND OPENABLE WINDOWS |
BS EN 12453:2001 | Industrial, commercial and garage doors and gates. Safety in use of power operated doors. Requirements |
BS EN 1366-7:2004 | Fire resistance tests for service installations Conveyor systems and their closures |
BS EN ISO 13943:2017 | Fire safety. Vocabulary |
BS EN 1634-3:2004 | Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware Smoke control test for door and shutter assemblies |
BS EN 14600:2005 | Doorsets and openable windows with fire resisting and/ or smoke control characteristics. Requirements and classification |
BS EN ISO 1182:2010 | Reaction to fire tests for products. Non-combustibility test |
BS 8524-2:2013 | Active fire curtain barrier assemblies Code of practice for application, installation and maintenance |
PREN 16034 : DRAFT 2009 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS |
BS 476-6(1989) : 1989 | FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 6: METHOD OF TEST FOR FIRE PROPAGATION FOR PRODUCTS |
BS EN 1363-2:1999 | Fire resistance tests Alternative and additional procedures |
BS 476-20:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of elements of construction (general principles) |
BS EN 13501-1 : 2007 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 1: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS |
1995/16/EC : 1995 | DIRECTIVE 95/16/EC OF 29 JUNE 1995 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO LIFTS |
BS EN 1363-1:2012 | Fire resistance tests General requirements |
BS EN ISO 11925-2:2010 | Reaction to fire tests. Ignitability of products subjected to direct impingement of flame Single-flame source test |
BS EN 12101-1 : 2006 | SMOKE AND HEAT CONTROL SYSTEMS - PART 1: SPECIFICATION FOR SMOKE BARRIERS |
BS EN ISO 1716:2010 | Reaction to fire tests for products. Determination of the gross heat of combustion (calorific value) |
BS EN 13823 : 2010 | REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - BUILDING PRODUCTS EXCLUDING FLOORINGS EXPOSED TO THE THERMAL ATTACK BY A SINGLE BURNING ITEM |
BS 7974:2001 | Application of fire safety engineering principles to the design of buildings. Code of practice |
BS 476-31.1:1983 | Fire tests on building materials and structures Methods for measuring smoke penetration through doorsets and shutter assemblies - Method of measurement under ambient temperature conditions |
BS EN 12101-10:2005 | Smoke and heat control systems Power supplies |
BS 9991:2011 | Fire safety in the design, management and use of residential buildings. Code of practice |
BS 476-22:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.