1 Scope
2 Normative references
3 Definitions
4 Components
5 Test assemblies
6 Range of compliance
7 Test sequences
8 Test results
Annex A (informative) - Identification of test
        cable (paper insulated)
Annex B (informative) - Identification of test
        cable (extruded insulation)

Defines performance requirements for type tests for cable accessories for use on impregnated paper insulated power cables as specified in HD 621.

Committee
GEL/20/11
DevelopmentNote
Supersedes BS 7888-4.2(1998) Also numbered as HD 629.2. (03/2006) Supersedes 03/315043 DC. (04/2006) Together with BS 7888-4.1(2006), BS EN 50393, and BS EN 61442 it supersedes BS 7888-1(1998) and BS 7888-2(1998). (08/2006) 2006 Edition Re-Issued in February 2009 & incorporates AMD 1 2008. (02/2009)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Current

EN 61238-1:2003 Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV) - Part 1: Test methods and requirements
IEC 61442:2005 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
BS 7870-4.13:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single core 33 kV copper wire/foil sheath cables - Section 4.13: Single core 33 kV copper wire/foil sheath cables
HD 631.1 : 200S2 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 1: FINGERPRINTING AND TYPE TESTS FOR RESINOUS COMPOUNDS
BS 7933-1:2007 Electric cables. Accessories. Material characterisation Fingerprinting and type tests for resinous compounds
BS 7894:2003 MV impregnated paper insulated distribution cables of rated voltages of 3.8/6.6 kV to 19/33 kV
HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
BS 7870-4.10(2011) : 2011 LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION OF RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.10: SINGLE-CORE 11 KV TO 33 KV CABLES (IMPLEMENTATION OF HD 620)
HD 428.2.2 : 200S1 THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 2: DISTRIBUTION TRANSFORMERS WITH CABLE BOXES ON THE HIGH-VOLTAGE AND/OR LOW VOLTAGE SIDE - SECTION 2: CABLE BOXES TYPE 1 FOR USE ON DISTRIBUTION TRANSFORMERS MEETING THE REQUIREMENTS OF HD 428.2.1 S1
BS 7821-2.2:1998 Three phase oil-immersed distribution transformers, 50 Hz, from 50 to 2500 kVA with highest voltage for equipment not exceeding 36 kV. Distribution transformers with cable boxes on the high voltage and/or low voltage side Cable boxes of type 1 for use on distribution transformers meeting the requirements of BS 7821-2.1
EN 50180:2010 Bushings above 1 kV up to 52 kV and from 250 A to 3,15 kA for liquid filled transformers – Part 1: General requirements for bushings
IEC 61238-1:2003 Compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV) - Part 1: Test methods and requirements
EN 61442:2005 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV)
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
EN 50181:2010 Plug-in type bushings above 1 kV up to 52 kV and from 250 A to 2,50 kA for equipment other than liquid filled transformers
HD 629.1 S2:2006/A1:2008 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION
HD 621 S1:1996/A1:2001 MV IMPREGNATED PAPER INSULATED DISTRIBUTION CABLES OF RATED VOLTAGES OF 3.8/6.6 KV TO 19/33 KV
BS 7870-4.12:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single core 11 kV copper foil sheath cables - Section 4.12: single core 11 kV copper foil sheath cables

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.