BS 7777-4:1993
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Specification for the design and construction of single containment tanks for the storage of liquid oxygen, liquid nitrogen and liquid argon
Hardcopy , PDF
26-11-2012
English
15-06-1993
Committees responsible
Foreword
Specification
1 Scope
2 References
3 Definitions
4 Design conditions
5 Information to be exchanged between the purchaser
and the contractor
5.1 Information to be supplied by the purchaser
5.2 Information and requirements to be agreed and to
be documented
6 Inner tank
6.1 Materials
6.2 Plate and fittings
6.3 Shell plate thickness
6.4 Weld metal
6.5 Bolting materials
6.6 Mountings
6.7 Loadings
6.8 Tank design
6.9 Nozzle and access opening design
6.10 Permanent attachments other than manholes and
nozzles
6.11 Temporary attachments
6.12 Interconnecting mountings (pipework)
6.13 Tank anchorage
7 Outer container
7.1 Materials
7.2 Loadings
7.3 Design
7.4 Mountings
7.5 Stairways, gangways, platforms and ladders
7.6 Anchorage
8 Shop fabrication
9 Site erection
10 Non-destructive testing
10.1 Radiography
10.2 Crack detection
10.3 Leak testing
11 Testing
11.1 General
11.2 Hydrostatic testing
11.3 Pneumatic testing
11.4 Test procedures
12 Cleanliness
13 Insulation
14 Foundation
15 Internal positive and internal negative pressure
relief
16 Commissioning and decommissioning
17 Name plate
Tables
1 Maximum shell plate thickness
2 Nominal shell thickness
Figure
1 Detail of lap welded inner roof
List of references
Specifies requirements for metallic cryogenic tanks of double wall single containment type operating in the range -180°C to -196°C.
Committee |
PVE/15
|
DevelopmentNote |
Supersedes BS 4741(1971) (07/2004) Supersedes 90/73037 DC and BS 5387(1976) (10/2005) Reviewed and confirmed by BSI, January 2008. (12/2007)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
BS 7777-3:1993 | Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Recommendations for the design and construction of prestressed and reinforced concrete tanks and tank foundations, and for the design and installation of tank insulation, tank liners and tank coatings |
BS 7777-1:1993 | Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Guide to the general provisions applying for design, construction, installation and operation |
EEMUA 154 : 2002 | DEMOLITION OF VERTICAL CYLINDRICAL STEEL STORAGE TANKS AND LPG SPHERES |
PD 7777:2000 | Alternative steel selection and its effect on design and testing of tanks to BS 7777 |
BS 7777-2:1993 | Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Specification for the design and construction of single, double and full containment metal tanks for the storage of liquefied gas at temperatures down to -165°C |
BS 3605-1:1991 | Austenitic stainless steel pipes and tubes for pressure purposes Specification for seamless tubes |
BS 1560-3.1:1989 | Circular flanges for pipes, valves and fittings (Class designated). Steel, cast iron and copper alloy flanges Specification for steel flanges |
BS 7777-2:1993 | Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Specification for the design and construction of single, double and full containment metal tanks for the storage of liquefied gas at temperatures down to -165°C |
PD 6501-1:1982 | The preparation of British Standards for building and civil engineering Guide to the types of British Standard, their aims, relationship, content and application |
BS EN 10028-1:2017 | Flat products made of steels for pressure purposes General requirements |
BS CP3:CH5-2(1972) : AMD 7908 | CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - LOADING - WIND LOADS |
BS 1501-2:1988 | Steels for pressure purposes Specification for alloy steels: plates |
BS 1503:1989 | Specification for steel forgings for pressure purposes |
BS 7777-3:1993 | Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Recommendations for the design and construction of prestressed and reinforced concrete tanks and tank foundations, and for the design and installation of tank insulation, tank liners and tank coatings |
BS EN 10045-1:1990 | Charpy impact test on metallic materials Test method (V- and U-notches) |
BS 3605-2:1992 | Austenitic stainless steel pipes and tubes for pressure purposes Specification for longitudinally welded tubes |
BS 7777-1:1993 | Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Guide to the general provisions applying for design, construction, installation and operation |