BS 7777-4:1993

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Specification for the design and construction of single containment tanks for the storage of liquid oxygen, liquid nitrogen and liquid argon

Available format(s)

Hardcopy , PDF

Withdrawn date

26-11-2012

Language(s)

English

Published date

15-06-1993

£142.00
Excluding VAT

Committees responsible
Foreword
Specification
1 Scope
2 References
3 Definitions
4 Design conditions
5 Information to be exchanged between the purchaser
      and the contractor
5.1 Information to be supplied by the purchaser
5.2 Information and requirements to be agreed and to
      be documented
6 Inner tank
6.1 Materials
6.2 Plate and fittings
6.3 Shell plate thickness
6.4 Weld metal
6.5 Bolting materials
6.6 Mountings
6.7 Loadings
6.8 Tank design
6.9 Nozzle and access opening design
6.10 Permanent attachments other than manholes and
      nozzles
6.11 Temporary attachments
6.12 Interconnecting mountings (pipework)
6.13 Tank anchorage
7 Outer container
7.1 Materials
7.2 Loadings
7.3 Design
7.4 Mountings
7.5 Stairways, gangways, platforms and ladders
7.6 Anchorage
8 Shop fabrication
9 Site erection
10 Non-destructive testing
10.1 Radiography
10.2 Crack detection
10.3 Leak testing
11 Testing
11.1 General
11.2 Hydrostatic testing
11.3 Pneumatic testing
11.4 Test procedures
12 Cleanliness
13 Insulation
14 Foundation
15 Internal positive and internal negative pressure
      relief
16 Commissioning and decommissioning
17 Name plate
Tables
1 Maximum shell plate thickness
2 Nominal shell thickness
Figure
1 Detail of lap welded inner roof
List of references

Specifies requirements for metallic cryogenic tanks of double wall single containment type operating in the range -180°C to -196°C.

Committee
PVE/15
DevelopmentNote
Supersedes BS 4741(1971) (07/2004) Supersedes 90/73037 DC and BS 5387(1976) (10/2005) Reviewed and confirmed by BSI, January 2008. (12/2007)
DocumentType
Standard
Pages
18
PublisherName
British Standards Institution
Status
Withdrawn
Supersedes

BS 7777-3:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Recommendations for the design and construction of prestressed and reinforced concrete tanks and tank foundations, and for the design and installation of tank insulation, tank liners and tank coatings
BS 7777-1:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Guide to the general provisions applying for design, construction, installation and operation
EEMUA 154 : 2002 DEMOLITION OF VERTICAL CYLINDRICAL STEEL STORAGE TANKS AND LPG SPHERES
PD 7777:2000 Alternative steel selection and its effect on design and testing of tanks to BS 7777
BS 7777-2:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Specification for the design and construction of single, double and full containment metal tanks for the storage of liquefied gas at temperatures down to -165°C

BS 3605-1:1991 Austenitic stainless steel pipes and tubes for pressure purposes Specification for seamless tubes
BS 1560-3.1:1989 Circular flanges for pipes, valves and fittings (Class designated). Steel, cast iron and copper alloy flanges Specification for steel flanges
BS 7777-2:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Specification for the design and construction of single, double and full containment metal tanks for the storage of liquefied gas at temperatures down to -165°C
PD 6501-1:1982 The preparation of British Standards for building and civil engineering Guide to the types of British Standard, their aims, relationship, content and application
BS EN 10028-1:2017 Flat products made of steels for pressure purposes General requirements
BS CP3:CH5-2(1972) : AMD 7908 CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - LOADING - WIND LOADS
BS 1501-2:1988 Steels for pressure purposes Specification for alloy steels: plates
BS 1503:1989 Specification for steel forgings for pressure purposes
BS 7777-3:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Recommendations for the design and construction of prestressed and reinforced concrete tanks and tank foundations, and for the design and installation of tank insulation, tank liners and tank coatings
BS EN 10045-1:1990 Charpy impact test on metallic materials Test method (V- and U-notches)
BS 3605-2:1992 Austenitic stainless steel pipes and tubes for pressure purposes Specification for longitudinally welded tubes
BS 7777-1:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service Guide to the general provisions applying for design, construction, installation and operation

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.