BS 7036-2:1996
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Code of practice for safety at powered doors for pedestrian use Straight and curved sliding doors and prismatic and folding doors
Hardcopy , PDF
31-10-2014
English
15-04-1996
Committees responsible
National foreword
Introduction
Specification
1 Scope
2 Normative references
3 Definitions
4 General performance requirements
5 Reference conditions
6 Absolute acoustical sensitivity
7 Frequency weighting
8 Linearity of response to steady signals
9 Response to short-duration signals
10 Response to unipolar pulses
11 Latching overload indicator
12 Sensitivity to various environments
13 Instrument marking
14 Instruction manual
Annexes
A (informative) Sound exposures and corresponding
normalized 8-h-average sound levels
B (informative) Recommended tests to verify the
performance of a personal sound exposure meter
Tables
1 Design-goal A-frequency weighting relative to
response at 1 kHz and the tolerances delta A that
apply to the performance of a complete personal
sound exposure meter
A.1 Sound exposures and corresponding normalized 8-h-
average sound levels
B.1 Minimum set of target conditions for 1 kHz steady-
signal linearity tests
B.2 Conditions for testing response to short-duration
signals
Figure
1 Functional elements of a personal sound exposure
meterCommittees responsible
Foreword
Code of practice
1 Scope
2 References
3 Definitions
4 General
5 Safety during the opening cycle
6 Pocket screens
7 Safety during the closing cycle
8 Detection zone verification
9 Means of escape
10 Break-out
11 Operation upon mains power interruption
Annexes
A (normative) Authorized technician check list
B (normative) Occupier safety tests
C (informative) Limitation of leaf forces
Tables
1 Suitability of safety devices to sliding doors
C.1 Minimum closing times for sliding doors
Figures
1 Example of barrier rail
2 Position of barrier at folding door
3 Example of a fixed screen forming a pocket
4 Avoidance of body traps
5 Avoidance of drawing-in hazards and finger traps
6 Dimensions of presence sensor threshold monitoring
field
7 Break-out: sliding doors and screens
A.1 Authorized technician check list for all types of
powered sliding doors
B.1 Occupier safety check list for all types of
powered sliding doors
List of references
Gives advice on the specific safety recommendations that apply to the following types of powered sliding doors: single and bi-parting curved sliding doors and prismatic doors; folding doors; single, bi-parting and telescopic straight sliding doors.
Committee |
B/538/9
|
DevelopmentNote |
Supersedes BS 7036(1988) (07/2004) To be read in conjunction with BS 7036-1(1996) Supersedes 95/709602 DC. (09/2005) Reviewed and confirmed by BSI, January 2010. (12/2009)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
14/30269311 DC : 0 | BS 7036-0 - POWER OPERATED PEDESTRIAN DOORSETS - SAFETY IN USE - PART 0: CODE OF PRACTICE FOR RISK ASSESSMENT AND RISK REDUCTION |
BS 5588-11:1997 | Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings |
BS 8300:2001 | Design of buildings and their approaches to meet the needs of disabled people. Code of practice |
PD 6686:2006 | Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries |
BS 7036-3:1996 | Code of practice for safety at powered doors for pedestrian use Swing doors and balanced doors |
BIP 3043 : 2005 | BS 8300 - DESIGN OF BUILDINGS AND THEIR APPROACHES TO MEET THE NEEDS OF DISABLED PEOPLE - CODE OF PRACTICE |
06/30133094 DC : DRAFT OCT 2006 | BS 7273-4 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 4: ACTUATION OF RELEASE MECHANISMS FOR DOORS |
BS 8300(2009) : 2009 | DESIGN OF BUILDINGS AND THEIR APPROACHES TO MEET THE NEEDS OF DISABLED PEOPLE - CODE OF PRACTICE |
08/30182649 DC : DRAFT MAY 2008 | BS 8300 - DESIGN OF BUILDINGS AND THEIR APPROACHES TO MEET THE NEEDS OF DISABLED PEOPLE - CODE OF PRACTICE |
BS 7273-4:2007 | Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors |
BS 7036-0:2014 | Power operated pedestrian doorsets. Safety in use Code of practice for risk assessment and risk reduction |
BS 7036-1:1996 | Code of practice for safety at powered doors for pedestrian use General |
BIP 3044 : 2005 | BS 8300 - DESIGN OF BUILDINGS AND THEIR APPROACHES TO MEET THE NEEDS OF DISABLED PEOPLE - CODE OF PRACTICE |
BS 7036-3:1996 | Code of practice for safety at powered doors for pedestrian use Swing doors and balanced doors |
BS 7036-1:1996 | Code of practice for safety at powered doors for pedestrian use General |
BS 6262:1982 | Code of practice for glazing for buildings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.