BS 6840-17:1991
Current
The latest, up-to-date edition.
Sound system equipment Methods for specifying and measuring the characteristics of standard volume indicators
Hardcopy , PDF
English
30-04-1991
Committees responsible
National foreword
Methods
1. Scope
2. Definitions
3. Reference indication
4. Reference voltage
5. Reference volume
6. Division of the scale
7. Amplitude-frequency response - Performance
requirement
8. Response time
9. Overswing - Performance requirement
10. Return time - Performance requirement
11. Reversibility error - Performance requirement
12. Input impedance - Performance requirement
13. Distortion introduced by the standard volume
indicator - Performance requirement
14. Temperature range - Performance requirement
15. Overload input level - Performance requirement
16. Rectifier - Performance requirement
17. Colour of scale and scale card
18. Mounting on panels - Presence of magnetic material
19. Mounting angle - Performance requirement
20. Classification of the characteristics to be
specified
Figures
1. Connection of the standard volume indicator
2. Schematic diagram of the method of measurement
of response time of the standard volume indicator
3. Scale of the standard volume indicator
Table
1. Attenuator characteristics 3,900 omega constant
impedance
Annex
ZA. (informative) Other international publications
quoted in this standard with the references of
the relevant European publications
National annex
NA (informative) Cross-references
Defines the characteristics, methods of measurement, scale colours and standard scale markings, and requirements for a built-in or external attenuator for VU indicators (VU-meters) for use in recording studios and broadcast control rooms.
Committee |
EPL/100
|
DevelopmentNote |
Also numbered as IEC 60268-17 Supersedes 88/26018 DC (09/2005)
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This standard gives the characteristics to be specified, performance requirements and the relevant methods of measurement for electro-mechanical volume indicators. The concept of “volume” is a practical way of assigning a numerical value to the magnitude of electrical speech and music programme signals.
Since the response of the meter movement of such an indicator to the rapidly varying programme voltage is greatly dependent upon its dynamic characteristics, a standard for volume measurements shall therefore include a specification of these characteristics. The term “vu” (pronounced “vee-you” and written with lower case letters) is used to express volume in terms of vu above or below a specified reference level.
This standard does not deal with peak programme level meters which are the subject of IEC 268-10.
BS 6259:2015 | Code of practice for the design, planning, installation, testing and maintenance of sound systems |
DEFSTAN 00-250(PT3)SEC1-7/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTIONS 1-7 - OVERALL CONTENTS/SCOPE |
DEFSTAN 00-250(PT1)/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 1: OVERARCHING PEOPLE-RELATED REQUIREMENTS |
DEFSTAN 00-250(PT3)SEC11/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 11 - TRAINING |
DEFSTAN 00-250(PT3)SEC13/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 13 - THE WORKPLACE |
DEFSTAN 00-250(PT3)SEC8/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 8 - PEOPLE IN SYSTEMS |
DEFSTAN 00-250(PT3)SEC9/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 9 - PEOPLE CHARACTERISTICS |
DEFSTAN 00-250(PT3)SEC10/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 10 - SYSTEMS SAFETY |
DEFSTAN 00-250(PT3)SEC15/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 15 - WORK EQUIPMENT |
DEFSTAN 00-250(PT3)SEC12/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 12 - OPERATIONS, MAINTENANCE & SUPPORT |
DEFSTAN 00-250(PT3)SEC16/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 16 - LIVING SPACES |
DEFSTAN 00-250(PT3)SEC14/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 14 - THE ENVIRONMENT |
DEFSTAN 00-250(PT2)/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 2: PARTICULAR PEOPLE-RELATED REQUIREMENTS |
BS 6840-10:1991 | Sound system equipment Methods for specifying and measuring the characteristics of peak programme level meters |
BS EN 60961:1994 | Specification for helical-scan video tape cassette system using 12,65 mm (0,5 in) magnetic tape on type L |
HD 483.10 : 200S1 | SOUND SYSTEM EQUIPMENT - PART 10: PEAK PROGRAMME LEVEL METERS |
IEC 60268-10:1991 | Sound system equipment - Part 10: Peak programme level meters |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.