BS 6840-10:1991

Current

Current

The latest, up-to-date edition.

Sound system equipment Methods for specifying and measuring the characteristics of peak programme level meters

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-08-1991

£198.00
Excluding VAT

Committees responsible
National foreword
Methods
Section 1. General
1.1 Scope
1.2 Normative references
Section 2. Conditions for specification and measurement
2.1 Conditions
2.2 Description of peak programme level meters
Section 3. Characteristics of peak programme level
           meters
3.1 Reference indication
3.2 Reference input voltage and reference input level
3.3 Division of the scale
3.4 Amplitude-frequency response
3.5 Dynamic response
3.6 Pulse response
3.7 Dynamic linearity with scale range
3.8 Dynamic response below minimum calibration point
3.9 Delay time
3.10 Integration time
3.11 Overswing
3.12 Return time
3.13 Reversibility error
3.14 Input impedance
3.15 Distortion introduced by the peak programme level
      meter
3.16 Temperature range
3.17 Overload characteristics
3.18 Maximum input level
3.19 Supply voltage range
Section 4. Peak programme level meters, type I
4.1 Reference indication
4.2 Reference input voltage and reference input level
4.3 Division of the scale
4.4 Amplitude-frequency response
4.5 Dynamic response
4.6 Integration time
4.7 Overswing
4.8 Return time
4.9 Reversibility error
4.10 Input impedance
4.11 Distortion introduced by the peak programme level
      meter
4.12 Temperature range
4.13 Overload characteristic
4.14 Maximum input level
4.15 Supply voltage range
Section 5. Peak programme level meters, type II
5.1 General
5.2 Reference indication
5.3 Reference input voltage
5.4 Indicating instrument
5.5 Amplitude-frequency response
5.6 Dynamic response
5.7 Pulse response (normal mode)
5.8 Dynamic linearity within scale range (normal mode)
5.9 Dynamic response below minimum calibration point
      (normal mode)
5.10 Delay time (normal mode)
5.11 Integration time
5.12 Overswing
5.13 Return time
5.14 Reversibility error
5.15 Input impedance
5.16 Distortion introduced by the peak programme level
      meter
5.17 Temperature range
5.18 Overload characteristic (normal mode)
5.19 Maximum input level
5.20 Supply voltage range
Section 6. Peak programme level meters having
           incremental display
6.1 General
6.2 Number of discrete elements in the display
6.3 Display resolution
6.4 Indication of levels
6.5 Optical characteristics of displays
6.6 Operation above reference indication
6.7 Displays using multiplex technique
6.8 Rate of element-switching (switch-on - switch-off
      times)
Section 7. Incremental peak programme level meters for
           secondary and consumer applications
7.1 General
7.2 Reference indication
7.3 Number of discrete elements in the display
7.4 Display resolution
7.5 Amplitude-frequency response
7.6 Integration time
7.7 Return time
7.8 Reversibility error
Section 8. Classification for the characteristics to be
           specified
8.1 Introduction
8.2 Classification
Annexes
A. (normative) Slow mode of operation
B. (informative) Details of preferred indicating
      instrument

Characteristics, relevant methods of measurement and performance requirements (in some cases) for audio frequency peak programme level meters for use in equipment for broadcasting, sound reinforcement, sound recording and household entertainment.

Committee
EPL/100
DevelopmentNote
Also numbered as IEC 60268-10 Supersedes BS 5428-9(1981) & 88/23048 DC (05/2003)
DocumentType
Standard
Pages
28
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of IEC 268 applies to audio-frequency peak programme level meters, for use in equipment for broadcasting, sound reinforcement, sound recording and household entertainment.

This standard does not apply to “Standard volume indicators” which is dealt with in IEC 268-17.

Standards Relationship
HD 483.10 : 200S1 Identical

BS 6259:2015 Code of practice for the design, planning, installation, testing and maintenance of sound systems
BS 6259:1997 Code of practice for the design, planning, installation, testing and maintenance of sound systems
DEFSTAN 00-250(PT3)SEC1-7/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTIONS 1-7 - OVERALL CONTENTS/SCOPE
DEFSTAN 00-250(PT1)/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 1: OVERARCHING PEOPLE-RELATED REQUIREMENTS
DEFSTAN 00-250(PT3)SEC11/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 11 - TRAINING
DEFSTAN 00-250(PT3)SEC8/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 8 - PEOPLE IN SYSTEMS
DEFSTAN 00-250(PT3)SEC15/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 15 - WORK EQUIPMENT
DEFSTAN 00-250(PT3)SEC9/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 9 - PEOPLE CHARACTERISTICS
DEFSTAN 00-250(PT3)SEC10/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 10 - SYSTEMS SAFETY
DEFSTAN 00-250(PT3)SEC13/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 13 - THE WORKPLACE
DEFSTAN 00-250(PT3)SEC12/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 12 - OPERATIONS, MAINTENANCE & SUPPORT
DEFSTAN 00-250(PT2)/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 2: PARTICULAR PEOPLE-RELATED REQUIREMENTS
DEFSTAN 00-250(PT3)SEC14/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 14 - THE ENVIRONMENT
DEFSTAN 00-250(PT3)SEC16/1(2008) : 2008 HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 16 - LIVING SPACES
BS 6840-18:1996 Sound system equipment Peak programme level meters. Guide for digital audio level meter
BS 7594:2011 Code of practice for audio-frequency induction-loop systems (AFILS)
BS 7594:1993 Code of practice for audio-frequency induction-loop systems (AFILS)

HD 483.3 : 200S2 SOUND SYSTEM EQUIPMENT - AMPLIFIERS
IEC 60268-3:2013 Sound system equipment - Part 3: Amplifiers
BS 6840-3:1989 Sound system equipment Methods for specifying and measuring the characteristics of sound system amplifiers
HD 483.1 : 200S2 SOUND SYSTEM EQUIPMENT - GENERAL
IEC 60268-1:1985 Sound system equipment. Part 1: General
BS 6840-1:1987 Sound system equipment Methods for specifying and measuring general characteristics used for equipment performance
HD 195 : 200S6 SAFETY REQUIREMENTS FOR MAINS OPERATED ELECTRONIC AND RELATED APPARATUS FOR HOUSEHOLD AND SIMILAR GENERAL USE
IEC 60268-17:1990 Sound system equipment. Part 17: Standard volume indicators
BS 6840-17:1991 Sound system equipment Methods for specifying and measuring the characteristics of standard volume indicators
HD 483.2 : 200S2 SOUND SYSTEM EQUIPMENT - EXPLANATION OF GENERAL TERMS AND CALCULATION METHODS
BS 6840-2:1988 Sound system equipment Glossary of general terms and calculation methods
HD 483.17 : 200S1 SOUND SYSTEM EQUIPMENT - STANDARD VOLUME INDICATORS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.