BS 6622:2007

Current

Current

The latest, up-to-date edition.

Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV. Requirements and test methods

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

29-08-2008

£290.00
Excluding VAT

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Voltage designation
5 Conductors
6 Conductor screen
7 Insulation
8 Insulation screen
9 Assembly of three-core cables, including inner coverings
    and fillers
10 Metallic layer
11 Metallic armour
12 Oversheath
13 Marking
14 End sealing
15 Schedule of tests
16 Test conditions
17 Routine tests
18 Sample tests
19 Type tests - Materials
20 Type tests - Electrical
Annexes
Annex A (informative) - Recommendations for the selection of
                        cables
Annex B (normative) - Information to be supplied and items
                      to be agreed
Annex C (informative) - Recommendations for the installation of
                        cables
Annex D (informative) - Guide to use of cables
Annex E (normative) - Fictitious calculation method for
                      determination of dimensions of protective
                      coverings
Annex F (normative) - Rounding of numbers
Annex G (informative) - Guidance on the scope of type tests
Annex H (normative) - Thickness measurements
Annex I (normative) - Test method for cold strippability of
                      the extruded semi-conducting layer of
                      an insulation screen
Annex J (normative) - Method for measurement of resistivity
                      of extruded semi-conducting conductor
                      screen and insulation screen
Annex K (normative) - Method for measurement of resistivity
                      of lapped inner covering
Annex L (normative) - Wet compatibility test for galvanized
                      steel wires and semi-conducting tape
                      layers
Bibliography

Defines requirements and test methods for the construction, dimensions and mechanical and electrical properties of armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 (7.2) kV up to 19/33 (36) kV inclusive, designed for a maximum continuous conductor operating temperature of 90 degrees C and for a maximum short circuit conductor temperature of 250 degrees C, for use in fixed installations such as networks or industrial installations.

Committee
GEL/20/16
DevelopmentNote
Supersedes BS 6622(1999) and 06/30143016 DC (03/2007) Reviewed and confirmed by BSI, October 2012. (09/2012)
DocumentType
Standard
Pages
60
PublisherName
British Standards Institution
Status
Current

This British Standard specifies requirements and test methods for the construction, dimensions and mechanical and electrical properties of armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 (7.2) kV up to 19/33 (36) kV inclusive, designed for a maximum continuous conductor operating temperature of 90 °C and for a maximum short circuit conductor temperature of 250 °C, for use in fixed installations such as networks or industrial installations.

This British Standard specifies single-core and three-core cables for voltages in the range 3.8/6.6 (7.2) kV up to 19/33 (36) kV, with:

  1. a stranded copper, stranded aluminium or solid aluminium conductor or conductors;
  2. cross-linked polyethylene or cross-linked ethylene propylene rubber insulation;
  3. a metallic screening layer of copper wire or copper tape and/or a metallic armour of aluminium or galvanized steel wire;
  4. a polyvinyl chloride compound (PVC) or polyethylene (PE) oversheath.

NOTE Guidance on the selection of cables is given in Annex A. Information to be supplied by the purchaser, and items to be agreed between the purchaser and the manufacturer, at the time of enquiry and/or order, are given in Annex B. Recommendations for the installation of cables are given in Annex C. Guidance on the use of cables is given in Annex D.

IEC 60038:2009 IEC standard voltages
BS 4727-2:GRP08(1994) : 1994 GLOSSARY OF ELECTROTECHNICAL, POWER, TELECOMMUNICATION, ELECTRONICS, LIGHTING AND COLOUR TERMS - TERMS PARTICULAR TO POWER ENGINEERING - ELECTRIC CABLES
IEC 60502-2:2014 RLV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
BS 7870-4.13:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single core 33 kV copper wire/foil sheath cables - Section 4.13: Single core 33 kV copper wire/foil sheath cables
BS EN 60332-1-2 : 2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004)
BS 7870-4.20:1999 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Three-core 11 kV cables - Three core 11 kV cables
BS EN 60228:2005 Conductors of insulated cables
BS EN 60811-1-1:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
BS EN 60811-1-3:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test
BS EN 10244-2:2009 Steel wire and wire products. Non-ferrous metallic coatings on steel wire Zinc or zinc alloy coatings
BS EN 60885-3:2015 Electrical test methods for electric cables Test methods for partial discharge measurements on lengths of extruded power cables
BS EN 50356:2002 Method for spark testing of cables
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
BS EN 60230:2002 Impulse tests on cables and their accessories
BS 7870-4.11:1999 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single-core 33 kV lead sheathed cables - Single core 33 kV lead sheathed cables
BS EN 60811-1-2:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods
BS EN 10002-1:2001 Tensile testing of metallic materials Method of test at ambient temperature
BS 7870-4.12:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single core 11 kV copper foil sheath cables - Section 4.12: single core 11 kV copper foil sheath cables

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.