BS 5857-1.1:1980
Current
The latest, up-to-date edition.
Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of water flow General
Hardcopy , PDF
English
31-03-1980
Cooperating organizations
National foreword
0 Introduction
1 Scope and field of application
2 Vocabulary and symbols
3 Units
4 Choice of method
5 Choice of tracer
6 Choice of measuring length and adequate mixing
distance
7 Errors
Annex Distribution table of chi squared (Pearson's law)
Publications referred to
Compares dilution methods and methods based on transit time measurement. Also covers choice of tracers and measuring/mixing lengths.
Committee |
CPI/30/5
|
DevelopmentNote |
Also numbered as ISO 2975-1 Supersedes 77/28083 DC (08/2005) Reviewed and confirmed by BSI, January 2008. (12/2007)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This International Standard deals with the measurement of water flow in closed conduits by using tracer methods; the flow of other liquids and of gases will be dealt with in subsequent International Standards
These methods apply to flow measurement in conduits into which a solution can be injected and those cases where effective mixing of this solution with the water flowing in the conduit can be achieved, this last condition being fundamental
Three fundamental procedures are used:
Two procedures, known as the constant rate injection method and the integration (sudden injection) method, are based on the dilution principle: a tracer solution is injected into the conduit and the dilution (ratio) of this tracer in the water flowing in the conduit is determined, this dilution being proportional to the rate of flow
The third is a method of measurement of the mean transit time (formerly called Allen velocity method): the tracer is injected into the conduit and the time taken by the tracer to travel a specified length between two cross-sections in each of which it is detected, is measured.
BS 5857-1.5:1980 | Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of water flow Transit time method using radioactive tracers |
BS EN 60041:1995 | Field acceptance tests to determine the hydraulic performance of hydraulic turbines, storage pumps and pump-turbines |
BS 0-3:1991 | A standard for standards Guide to drafting and presentation of British Standards |
BS 5316-3:1988 | Specification for acceptance tests for centrifugal, mixed flow and axial pumps Precision class tests |
BS 5857-1.4:1980 | Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of water flow Transit time method using non-radioactive tracers |
ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |
BS 5875:1980 | Glossary of terms and symbols for measurement of fluid flow in closed conduits |