BS 5839-4:1988
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Fire detection and alarm systems for buildings Specification for control and indicating equipment
Hardcopy , PDF
28-10-2002
English
29-04-1988
Foreword
Committees responsible
Specification
Section one. General
1. Scope
2. Definitions
Section two. Requirements
3. Functional requirements
4. Construction requirements
5. Electrical requirements
6. Marking and data
Section three. Tests
7. General details of tests
8. Dry heat
9. cold
10. Damp heat (steady state), insulation resistance
and dielectric strength
11. Vibration (operational)
12. Vibration (endurance)
13. Electrostatic discharges
14. Electromagnetic interference
15. Electrical fast transients
16. Variations in power supply
17. Battery charging
Appendix
A. Functional test
Tables
1. Accessibility levels for controls and indications
2. Test voltages for dielectric strength
3. Voltage and load combinations
Requirements and tests for the equipment, including any associated power supply unit. Does not cover indicating equipment installed at remote manned centres.
Committee |
FSH/12
|
DevelopmentNote |
REPLACES BS 3116: PART 4: 1974
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
BS 5445-8:1984 | Components of automatic fire detection systems Specification for high temperature heat detectors |
BS 5839-1:1988 | Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing |
BS 6259:1997 | Code of practice for the design, planning, installation, testing and maintenance of sound systems |
BS 7273-1:1990 | Code of practice for the operation of fire protection measures Electrical actuation of gaseous total flooding extinguishing systems. |
BS 7807:1995 | Code of practice for design, installation and servicing of integrated systems incorporating fire detection and alarm systems and/or other security systems for buildings other than dwellings |
06/30133094 DC : DRAFT OCT 2006 | BS 7273-4 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 4: ACTUATION OF RELEASE MECHANISMS FOR DOORS |
PD 6531:1997 | Queries and interpretations on BS 5839:Parts 1 and 4 (as amended) |
BS 5306-2:1990 | Fire extinguishing installations and equipment on premises Specification for sprinkler systems |
BS 5908:1990 | Code of practice for fire precautions in the chemical and allied industries |
BS 6266:1992 | Code of practice for fire protection for electronic data processing installations |
PD 6531:2010 | Queries and interpretations on BS 5839-1 |
PD 6686:2006 | Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries |
BS 7273-4:2007 | Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors |
DEFSTAN 02-603/2(2001) : INTERIM | REQUIREMENTS FOR THE POLICY, DESIGN AND INSTALLATION OF FIRE DETECTION SYSTEMS IN SHIPS |
BS 7443:1991 | Specification for sound systems for emergency purposes |
BS 5839-6:1995 | Fire detection and alarm systems for buildings Code of practice for the design and installation of fire detection and alarm systems in dwellings |
PD 6531:1992 | Queries and interpretations on BS 5839:Parts 1 and 4 (as amended) |
BS 5588-12:2004 | Fire precautions in the design, construction and use of buildings Managing fire safety |
BS 4163:2000 | HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN SCHOOLS AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE |
BS 2011-2.1A:1977 | Environmental testing. Tests Tests A. Cold |
BS 2011-2.1B:1977 | Environmental testing. Tests Tests B. Dry Heat |
BS 5839-1:1988 | Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing |
IEC 60801-4:1988 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 4: Electrical fast transient/burst requirements |
BS 5445-9:1984 | Components of automatic fire detection systems Methods of test of sensitivity to fire |
BS 6667-3:1985 | Electromagnetic compatibility for industrial-process measurement and control equipment Method of evaluating susceptibility to radiated electromagnetic energy |
BS 2011-2.1Ca:1977 | Environmental testing. Tests Test Ca. Damp heat, steady state |
BS 6667-2:1985 | Electromagnetic compatibility for industrial-process measurement and control equipment. Method of evaluating susceptibility to electrostatic discharge |
BS 5445-8:1984 | Components of automatic fire detection systems Specification for high temperature heat detectors |
BS CP3:CH4-1(1971) : AMD 2708 | CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - PRECAUTIONS AGAINST FIRE - FLATS AND MAISONETTES - (IN BLOCKS OVER TWO STOREYS) |
BS 5445-5:1977 | Components of automatic fire detection systems Heat sensitive detectors - point detectors containing a static element |
BS 5445-1:1977 | Components of automatic fire detection systems Introduction |
BS 5445-7:1984 | Components of automatic fire detection systems Specification for point-type smoke detectors using scattered light, transmitted light or ionization |