
BS 5618:1985
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Code of practice for thermal insulation of cavity walls (with masonry or concrete inner and outer leaves) by filling with urea-formaldehyde (UF) foam systems
Hardcopy , PDF
02-01-2024
English
31-07-1985
Foreword
Committees responsible
Code of practice
1. Scope
2. Definitions
3. Suitability of cavity walls for insulation
4. Material composition
5. Thermal performance of installed foam
6. The filling process
7. Installation of the UF foam system
8. Post-installation activities
9. Records
10. Declaration
Appendices
A. Criteria for suitability of external cavity walls
B. Natural stones used in the construction of
masonry walls
C. Calculation of the exposure index E of a building
(tabular method)
D. Calculation of the exposure index E (formula
method)
E. Driving-rain index
F. Comparison of methods for assessing exposure to
wind-driven rain
G. Formaldehyde
H. Flue checks for appliances of rated input not
exceeding 60 kW
J. Properties of the installed (UF) foam
K. Methods for determination of cavity width
Tables
1. Quality checks on site during or prior to
installation
2. Geographic factor G
3. Topographic factor T
4. Terrain roughness factor R
5. Topographic factor S
6. Equations for Bc
7. Comparisons between exposure values in DD 93 and
in this code
Figures
1. Staggered drilling pattern (representing maximum
spacing)
2. Drilling and filling patterns at damp proof course
and party lines
3. Unit area plan
4. Overall pattern of filling for a nominal 50 mm
width cavity
4a. Types of rubble walling
5. Maximum height of external cavity wall
6. Effective height of a partially protected cavity
wall
7. Height of location for buildings on or close to
steeply rising ground
8. Relationship between the exposure index used in
this code and the maximum directional spell index
in DD 93
9. Measurement of cavity width
10. Estimation of cavity width
Maps
Key to driving-rain index maps 1 to 30
1-30 Driving-rain index
31 Annual mean driving-rain index 'roses'
This edition updates the selection procedure for suitable properties and significantly tightens the requirements for the installation procedure.
Committee |
B/540
|
DevelopmentNote |
Supersedes 85/35766 DC, 87/42098 DC, 91/40404 DC and BS 5618(1978) (08/2005) Reviewed and confirmed by BSI, November 2012. (10/2012)
|
DocumentType |
Standard
|
Pages |
62
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
This British Standard code of practice describes recommendations for the installation of urea-formaldehyde (UF) foam systems which are dispensed on site, to fill the cavities of suitably situated and constructed external walls of maximum height 12 m, which have masonry or concrete inner and outer leaves, thereby providing additional thermal insulation to such walls. It defines what are suitably situated and constructed external walls and indicates essential procedures and precautions for the filling process. Walls built of random rubble are not covered by this code.
NOTE The titles of the publications referred to in this code are listed on the inside back cover.
BS 8211-1:1988 | Energy efficiency in housing Code of practice for energy efficient refurbishment of housing |
S.R. 325:2013+A2:2018/AC:2019 | RECOMMENDATIONS FOR THE DESIGN OF MASONRY STRUCTURES IN IRELAND TO EUROCODE 6 |
BS 5628-3:2005 | Code of practice for the use of masonry Materials and components, design and workmanship |
BS 5628-3:2001 | Code of practice for use of masonry Materials and components, design and workmanship |
10/30168896 DC : 0 | PD 6697 - RECOMMENDATIONS FOR THE DESIGN OF MASONRY STRUCTURES TO BS EN 1996-1-1 AND BS EN 1996-2 |
BS 8208-1:1985 | Guide to assessment of suitability of external cavity walls for filling with thermal insulants Existing traditional cavity construction |
BS 8104:1992 | Code of practice for assessing exposure of walls to wind-driven rain |
PD 6697:2010 | Recommendations for the design of masonry structures to BS EN 1996-1-1 and BS EN 1996-2 |
I.S. 325-2:1995 | CODE OF PRACTICE FOR USE OF MASONRY - PART 2: MASONRY CONSTRUCTION |
BS 5617:1985 | Specification for urea-formaldehyde (UF) foam systems suitable for thermal insulation of cavity walls with masonry or concrete inner and outer leaves |
05/30131954 DC : DRAFT APR 2005 | BS 5628-3 - CODE OF PRACTICE FOR THE USE OF MASONRY - PART 3: MATERIALS AND COMPONENTS, DESIGN AND WORKMANSHIP |
BS 5440-1:1978 | Installation of flues and ventilation for gas appliances of rated input not exceeding 60 kW (1st, 2nd and 3rd family gases). Flues |
BS 5628-3:1985 | Code of practice for use of masonry Materials and components, design and workmanship |
BS CP3:CH5-2(1972) : AMD 7908 | CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - LOADING - WIND LOADS |
BS 5617:1985 | Specification for urea-formaldehyde (UF) foam systems suitable for thermal insulation of cavity walls with masonry or concrete inner and outer leaves |
BS DD93(1984) : 1984 | METHODS FOR ASSESSING EXPOSURE TO WIND-DRIVEN RAIN |
BS 8208-1:1985 | Guide to assessment of suitability of external cavity walls for filling with thermal insulants Existing traditional cavity construction |
BS 5262:1976 | Code of practice. External rendered finishes |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.