1 Scope
2 Normal and special service conditions
3 Definitions
4 Rating
4.1 Rated voltage
4.2 Rated insulation level
4.3 Rated frequency
4.4 Rated normal current and temperature rise
4.5 Rated short-time withstand current
4.6 Rated peak withstand current
4.7 Rated duration of short-circuit
4.8 Rated supply voltage of closing and opening
devices and auxiliary circuits
4.9 Rated supply frequency of operating devices and
auxiliary circuits
4.10 Rated pressure of compressed gas supply for
operating mechanisms
4.101 Rated density of gas for insulation
5 Design and construction
5.1 Requirements for liquids in switchgear and
controlgear
5.2 Requirements for gases in switchgear and
controlgear
5.3 Earthing
5.4 Auxiliary equipment
5.5 Dependent power closing
5.6 Stored energy closing
5.7 Operation of releases
5.8 Low and high pressure interlocking devices
5.9 Nameplates
5.101 Degree of protection
5.102 Internal fault
5.103 Enclosures
5.104 Partitions
5.105 Pressure relief
5.106 Disconnectors and earthing switches
5.107 Interlocks
5.108 Noise
5.109 Provisions for dielectric tests on cables
6 Type tests
6.1 Dielectric tests
6.2 Radio interference voltage (RIV) tests
6.3 Temperature-rise tests
6.4 Measurement of the resistance of the main circuit
6.5 Short-time and peak withstand current tests
6.101 Verification of making and breaking capacities
6.102 Mechanical operation tests
6.103 Verification of the degree of protection for
auxiliary circuits and moving parts
6.104 Proof tests for enclosures
6.105 Weatherproofing test
6.106 Test under conditions of arcing due to an
internal fault
6.107 Thermal stability test
6.108 Operation tests at limit temperatures
6.109 Gas tightness tests
7 Routine tests
7.1 Power-frequency voltage tests on the main circuit
7.2 Dielectric tests on auxiliary and control
circuits
7.3 Measurement of the resistance of the main circuit
7.101 Partial discharge measurement
7.102 Pressure tests of enclosures
7.103 Gas tightness tests
7.104 Mechanical operation tests
7.105 Tests of auxiliary electrical, pneumatic and
hydraulic devices
7.106 Verification of the correct wiring
7.107 Tests after erection on site
8 Guide to the selection of the switchgear for
service
National annex NA (informative)
Gives requirements for gas-insulated metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pressure, for alternating current of voltages of 72,5 kV and above, for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. The term 'switchgear' is used for 'gas-insulated metal-enclosed switchgear'. The gas-insulated metal-enclosed switchgear consists of individual components directly connected together and able to operate only in this manner. Completes and amends, the various relevant standards applying to the individual components constituting gas-insulated metal-enclosed switchgear. BS AMD 9211 RENUMBERS THIS STANDARD
Committee |
PEL/92
|
DevelopmentNote |
Supersedes BS 5524(1987), 87/21834 DC and 93/200463 DC. Renumbered and superseded by BS EN 60517. (04/2005)
|
DocumentType |
Standard
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
IEC 60517:1990 | Identical |
BS 923-2:1980 | Guide on high-voltage testing techniques Test procedures |
BS 4727-2:GRP06(1985) : 1985 | GLOSSARY OF ELECTROTECHNICAL POWER TELECOMMUNICATION ELECTRONICS LIGHTING AND COLOUR TERMS - TERMS PARTICULAR TO POWER ENGINEERING - SWITCHGEAR & CONTROLGEAR TERMINOLOGY INCLUDING FUSE TERMINOLOGY |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.