BS 5258-15:1990
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Safety of domestic gas appliances Specification for combination boilers
Hardcopy , PDF
15-04-1996
English
30-11-1990
Committees responsible
Foreword
Specification
Section 1. General
1 Scope
2 Definitions
3 Classification of appliances
4 General requirements
5 General conditions of test
Section 2. Safety requirements and associated methods of
test
6 General design and construction
7 Soundness
8 Heat input
9 Combustion
10 Ignition
11 Ignition system
12 Flame stability
13 Sooting
14 Flue system
15 Fire hazard and limiting temperatures
16 Manual controls
17 Automatic controls
18 Full sequence automatic control systems
19 Electrical safety
20 User's instructions
21 Installation and servicing
Appendices
A Calculation of flue draught
B Method of test for resistance to airborne lint
C Recommended method for determination of soundness of
the combustion system of fan-powered appliances
D Apparatus and conditions for combustion tests on
type C1 appliances
E Apparatus for combination tests on type C2
appliances
F Information to be supplied by the manufacturer
Test methods for boiler/water heater appliances of rated heat input not exceeding 60 kW burning 1st, 2nd and 3rd family gases. For use on open water systems and on sealed systems of stored hot water capacity not exceeding 15 l.
Committee |
GSE/29
|
DevelopmentNote |
Supersedes 87/75710 DC. (07/2005)
|
DocumentType |
Standard
|
Pages |
54
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
BS 5449:1990 | Specification for forced circulation hot water central heating systems for domestic premises |
BS 5546:2010 | Specification for installation and maintenance of gas-fired water-heating appliances of rated input not exceeding 70 kW net |
BS 5546:2000 | Specification for installation of hot water supplies for domestic purposes, using gas-fired appliances of rated input not exceeding 70 kW |
BS 5482-1:1994 | Domestic butane- and propane-gas-burning installations Specification for installations at permanent dwellings |
BS 6700:1997 | Specification for design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages |
09/30166542 DC : 0 | BS 5546 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED WATER-HEATING APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET |
BS PAS 33(1999) : 1999 | SPECIFICATION FOR THE DESIGN, INSTALLATION AND COMMISSIONING OF GAS FIRED CENTRAL HEATING SYSTEMS IN DOMESTIC PREMISES |
BS 476-4:1970 | Fire tests on building materials and structures Non-combustibility test for materials |
BS 5386-1:1976 | Specification for gas burning appliances Gas burning appliances for instantaneous production of hot water for domestic use |
BS 5963:1981 | Specification for electrically operated automatic gas shut-off valves |
BS 3016:1989 | Specification for pressure regulators for liquefied petroleum gases |
BS 3955:1986 | Specification for electrical controls for household and similar general purposes |
BS 1179-6:1980 | Glossary of terms used in the gas industry Combustion and utilization including installation at consumers\' premises |
BS 567:1973 | Specification for asbestos-cement flue pipes and fittings, light quality |
BS 6047-1:1981 | Flame supervision devices for domestic, commercial and catering gas appliances Specification for heat sensitive type |
BS 6700:1997 | Specification for design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages |
BS 5482-1:1979 | Domestic butane- and propane-gas-burning installations Installations in permanent dwellings |
BS 2871-1:1971 | Specification for copper and copper alloys. Tubes Copper tubes for water, gas and sanitation |
BS 6795:1987 | Specification for full sequence automatic control systems used on gas-fired appliances |
BS 6448-1:1987 | Gas governors Specification for pressure governors with nominal connection size up to 50 mm for gas appliances with inlet pressure up to and including 200 mbar |
BS 5482-2:1977 | Domestic butane- and propane-gas-burning installations Installations in caravans and non-permanent dwellings |
BS 1963:1990 | Specification for pressure operated relay valves for domestic, commercial and catering gas appliances |
BS 6759-1:1984 | Safety valves Specification for safety valves for steam and hot water |
BS 715:1993 | Specification for metal flue pipes, fittings, terminals and accessories for gas-fired appliances with a rated input not exceeding 60 kW |
BS 835:1973 | Specification for asbestos-cement flue pipes and fittings, heavy quality |
BS 5494:1978 | Specification for gas taps for domestic and catering appliances |
BS 1179:1967 | Glossary of terms used in the gas industry |
BS 6067:1981 | Specification for multifunctional gas controls for domestic, commercial and catering appliances |
BS 5449-1:1977 | Code of practice for central heating for domestic premises. Forced circulation hot water systems |
BS 5482-3:1979 | Domestic butane- and propane-gas-burning installations Installations in boats, yachts and other vessels |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.