BS 4843:1987
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Specification for sterile intravascular cannula units for single use
Hardcopy , PDF
15-09-1997
English
30-04-1987
Foreword
Committees responsible
Specification
1. Scope
2. Definition
3. Cannula unit
4. Cannula
5. Introducer needle
Appendices
A. Guidance on materials and design of cannula units
B. Method for determining the flow rate of water
through the cannula
C. Symbol for 'single use'
D. Method for determining the strength of union of
cannula and cannula hub assembly
E. Method of test for liquid leakage from cannula hub
assembly under pressure
F. Method of test for air leakage into the cannula hub
during aspiration
G. Method of test for resistance of cannula to breakage
on repeated bending
H. Method of test for corrosion resistance
Figures
1. Schematic diagram of intravascular cannula unit
2. Example of apparatus for determination of flow rate
of water throught the cannula
3. ISO symbol for single use, number ISO 7000/1051
4. General arrangement of test for resistance of
cannula to breakage on repeated bending
Size designation, surface finish, freedom from biological hazard, packaging, marking and certain performance characteristics of the cannula unit (comprising the cannula and introducer needle).
Committee |
CH/84
|
DevelopmentNote |
BS DRAFT 91/53634 DC
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE 111600:1992 | Identical |
BS 5736-2:1981 | Evaluation of medical devices for biological hazards Method of testing by tissue implantation |
BS 5736-6:1983 | Evaluation of medical devices for biological hazards Methods of test for sensitization; assessment of the potential of medical devices to produce delayed contact dermatitis |
ISO 3461:1976 | Graphic symbols — General principles for presentation |
BS 5736-4:1981 | Evaluation of medical devices for biological hazards Method of test for intracutaneous reactivity of extracts from medical devices |
BS 5404-2:1977 | Specification for plastics laboratory ware Graduated measuring cylinders |
BS 5736-1:1979 | Evaluation of medical devices for biological hazards Guide for the selection of biological methods of test |
BS 5736-5:1982 | Evaluation of medical devices for biological hazards Method of test for systemic toxicity; assessment of pyrogenicity in rabbits of extracts from medical devices |
BS 5736-3:1981 | Evaluation of medical devices for biological hazards Method of test for systemic toxicity; assessment of acute toxicity of extracts from medical devices |
BS 5081-1:1987 | Sterile hypodermic syringes and needles Specification for sterile hypodermic syringes for single use |
BS 5736-8:1984 | Evaluation of medical devices for biological hazards Method of test for skin irritation of solid medical devices |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
BS 5736-7:1983 | Evaluation of medical devices for biological hazards Method of test for skin irritation of extracts from medical devices |
BS 3930-1(1987) : AMD 8072 | CONICAL FITTINGS WITH A 6% (LUER) TAPER FOR SYRINGES, NEEDLES AND OTHER MEDICAL EQUIPMENT - SPECIFICATION FOR GENERAL REQUIREMENTS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.