BS 4580:1970
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Specification for number designation of organic refrigerants
Hardcopy , PDF
01-01-2004
English
13-03-1970
NO CONTENTS SECTION
Specifies a system of designating common organic refrigerants in an accurate and concise way by the use of a number, for each refrigerant covered, as an alternative to the use of the chemical name, formula or trade name.
Committee |
RHE/18
|
DocumentType |
Standard
|
Pages |
10
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Standards | Relationship |
UNE-EN 16272-5:2024 | Identical |
UNE-EN ISO 20504:2019 | Identical |
BS EN 60068-2-45:1993 | Environmental testing. Test methods Environmental testing. Tests. Test XA and guidance. Immersion in cleaning solvents |
BS 7120:1989 | Specification for rating and performance of air to liquid and liquid to liquid chilling packages |
BS 4376:1982 | Specification for electrically operated blood storage refrigerators |
BS 1586:1982 | Methods for performance testing and presentation of performance data for refrigerant condensing units |
BS EN 441-8:1995 | Refrigerated display cabinets Water vapour condensation test |
BS 5045-2:1989 | Transportable gas containers Specification for steel containers of 0.5 L up to 450 L water capacity with welded seams |
BS 2501:1992 | Specification for commercial refrigerated storage cabinets of the closed reach-in type |
BS 1710:1984 | Specification for identification of pipelines and services |
BS 2626:1992 | Specification for lubricants for refrigerant compressors |
BS 5045-6:1987 | Transportable gas containers Specification for seamless containers of less than 0.5 litre water capacity |
BS 6880-2:1988 | Code of practice for low temperature hot water heating systems of output greater than 45 kW Selection of equipment |
BS 4376-1:1991 | Electrically operated blood storage refrigerators Specification for closed reach-in types |
BS EN 50087:1993 | Safety of household and similar electrical appliances. Particular requirements for bulk-milk coolers |
BS 5355:1976 | Specification for filling ratios and developed pressures for liquefiable and permanent gases |
BS 7122:1989 | Specification for welded steel tanks for the road transport of liquefiable gases |
BS 853(1990) : 1990 AMD 8979 | SPECIFICATION FOR VESSELS FOR USE IN HEATING SYSTEMS - CALORIFIERS AND STORAGE VESSELS FOR CENTRAL HEATING AND HOT WATER SUPPLY |
BS 853-1(1996) : 1996 | SPECIFICATION FOR VESSELS FOR USE IN HEATING SYSTEMS - CALORIFIERS AND STORAGE VESSELS FOR CENTRAL HEATING AND HOT WATER SUPPLY |
BS 4376-2:1996 | Electrically operated blood storage refrigerators Specification for cabinets for the storage of frozen plasma |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.