ASTM F 526 : 2016 : REDLINE

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Using Calorimeters for Total Dose Measurements in Pulsed Linear Accelerator or Flash X-ray Machines

Available format(s)

PDF

Superseded date

13-08-2021

Language(s)

English

Published date

01-06-2016

£63.73
Excluding VAT

CONTAINED IN VOL. 10.04, 2016 Defines a calorimetric measurement of the total dose delivered in a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode) used as an ionizing source in radiation-effects testing.

Committee
E 10
DocumentType
Redline
Pages
15
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This test method covers a calorimetric measurement of the total absorbed dose delivered in a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode) used as an ionizing source in radiation-effects testing. The test method is designed for use with pulses of electrons in the energy range from 10 to 50 MeV and is only valid for cases in which both the calorimeter and the test specimen to be irradiated are “thin” compared to the range of these electrons in the materials of which they are constructed.

1.2The procedure described can be used in those cases in which (1) the dose delivered in a single pulse is 5 Gy(matl)2 [500 rd (matl)] or greater, or (2) multiple pulses of a lower dose can be delivered in a short time compared to the thermal time constant of the calorimeter. The units for the total absorbed dose delivered to a material require the specification of the material and the notation “matl” refers to the active material of the calorimeter. The minimum dose per pulse that can be acceptably monitored depends on the variables of the particular test, including pulse rate, pulse uniformity, and the thermal time constant of the calorimeter.

1.3A determination of the total dose is made directly for the material of which the calorimeter block is made. The total dose in other materials can be calculated from this measured value by formulas presented in this test method. The need for such calculations and the choice of materials for which calculations are to be made shall be subject to agreement by the parties to the test.

1.4The values stated in SI units are to be regarded as the standard. The values in parenthesis are provided for information only.

1.5This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

MIL-STD-750-3 Base Document:2012 Transistor Electrical Test Methods for Semiconductor Devices Part 3: Test Methods 3000 Through 3999
ASTM F 448 : 2011-07 TEST METHOD FOR MEASURING STEADY-STATE PRIMARY PHOTOCURRENT
MIL-STD-883 Revision K:2016 TEST METHOD STANDARD - MICROCIRCUITS
MIL-HDBK-817 Base Document:1994 SYSTEM DEVELOPMENT RADIATION HARDNESS ASSURANCE
ASTM F 744M : 2016 : REDLINE Standard Test Method for Measuring Dose Rate Threshold for Upset of Digital Integrated Circuits (Metric)
ASTM F 1893 : 2011-02 GUIDE FOR MEASUREMENT OF IONIZING DOSE-RATE SURVIVABILITY AND BURNOUT OF SEMICONDUCTOR DEVICES
MIL-HDBK-815 Base Document:1994 DOSE-RATE HARDNESS ASSURANCE GUIDELINES
ASTM F 675 : 1991 Test Method for Measuring Nonequilibrium Transient Photocurrents in P-N Junctions (Withdrawn 1995)
ASTM F 1032 : 1991 Guide for Measuring Time-Dependant Total-Dose Effects in Semiconductor Devices Exposed to Pulsed Ionizing Radiation (Withdrawn 1994)
ASTM F 773 : 1992 Practice for Measuring Dose Rate Response of Linear Integrated Circuits
ASTM F 773M : 2016 : REDLINE Standard Practice for Measuring Dose Rate Response of Linear Integrated Circuits (Metric)

ASTM E 230 : 2003 Standard Specification and Temperature-Electromotive Force (EMF) Tables for Standardized Thermocouples
ASTM E 170 : 2017 : REDLINE Standard Terminology Relating to Radiation Measurements and Dosimetry
ASTM E 1894 : 2013-07 GUIDE FOR SELECTING DOSIMETRY SYSTEMS FOR APPLICATION IN PULSED X-RAY SOURCES

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.