• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM F 3278 : 2017

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Performance Specification for Hand-Held Metal Detectors Used in Safety and Security

Available format(s)

Hardcopy , PDF

Superseded date

07-05-2019

Superseded by

ASTM F 3278 : 2019

Language(s)

English

Published date

01-10-2017

£63.73
Excluding VAT

CONTAINED IN VOL. 15.08, 2017 Pertains to all hand-held metal detectors (HHMDs) used to find metal contraband concealed or hidden on people or other objects with accessible surfaces.

Committee
F 12
DocumentType
Standard
Pages
13
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This performance specification applies to all hand-held metal detectors (HHMDs) used to find metal contraband concealed or hidden on people or other objects with accessible surfaces. This performance specification describes baseline performance requirements, which includes metal object detection performance, safety (electrical, mechanical, fire), electromagnetic compatibility, environmental conditions and ranges, and mechanical durability. The requirements for metal detection performance are unique and, therefore, test methods for these parameters are provided, including the design of test objects. An agency or organization using this performance specification is encouraged to add their unique operationally-based requirements to those requirements listed in this baseline performance specification.

1.2This performance specification describes the use of spherical test objects, instead of actual threat objects or exemplars of threat objects, to test the detection performance of hand-held metal detectors. Spherical test objects are used because the detectability of spherical test objects is not orientation dependent, whereas this is not true for non-spherical test objects. This orientation-dependent detectability of non-spherical test objects may allow a HHMD to be incorrectly attributed a higher performance capability than that HHMD is capable of providing. To aid agencies wishing to add specific threat objects to their detection performance requirements, included in Annex A1 is the analysis of the probability of detection for different orientations of agency-specific threat objects.

1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM F 3356 : 2019 Standard Specification for Conformity Assessment of Metal Detectors Used in Safety and Security

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ISO 14708-7:2013 Implants for surgery Active implantable medical devices Part 7: Particular requirements for cochlear implant systems
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
ANSI S1.4 : 1983 SPECIFICATION FOR SOUND LEVEL METERS
MIL-STD-810 Revision G:2008 ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS
ISO 14708-5:2010 Implants for surgery Active implantable medical devices Part 5: Circulatory support devices
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 60068-2-31:2008 Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
ISO 14117:2012 Active implantable medical devices Electromagnetic compatibility EMC test protocols for implantable cardiac pacemakers, implantable cardioverter defibrillators and cardiac resynchronization devices
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
ISO 14708-2:2012 Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers
ISO 14708-1:2014 Implants for surgery — Active implantable medical devices — Part 1: General requirements for safety, marking and for information to be provided by the manufacturer
ISO 14708-3:2017 Implants for surgery — Active implantable medical devices — Part 3: Implantable neurostimulators
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
ISO 14708-4:2008 Implants for surgery Active implantable medical devices Part 4: Implantable infusion pumps
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEEE C95.1-2005 IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz
IEC 61000-6-1:2016 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
ISO 10012:2003 Measurement management systems — Requirements for measurement processes and measuring equipment
IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
ISO 14708-6:2010 Implants for surgery Active implantable medical devices Part 6: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.