ASTM F 2824 : 2010 : R2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Mechanical Seal Strength Testing for Round Cups and Bowl Containers with Flexible Peelable Lids
Hardcopy , PDF
15-06-2021
English
01-04-2015
CONTAINED IN VOL. 15.10, 2015 Defines method for the measurement of mechanical seal strength while separating the entire lid (cover/membrane) from a rigid or semi-rigid round container.
Committee |
F 02
|
DocumentType |
Test Method
|
Pages |
6
|
ProductNote |
Reconfirmed 2015
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This test method describes a method for the measurement of mechanical seal strength while separating the entire lid (cover/membrane) from a rigid or semi-rigid round container.
1.2This test method differs from Test Method F88. Test Method F88 tests a portion of the seal where as this test method tests the force required to separate the entire lid (cover/membrane) from the container.
1.3This test method is used to determine the continuous and maximum forces required to separate the lid (cover/membrane) from the container.
1.4This test method uses an angle of pull of 45°, however other angles of pull may be used provided results are documented noting the used angle of pull and said procedure is validated.
1.5Typical examples of container shapes that could be tested using this or a similar method include oval, rectangular, and circular with single or multiple cavities having a sealed lid (cover/membrane). Examples of products packaged in these types of containers are: ready meals, creamers, coffee, yogurts, household fresheners, chemical and pharmaceutical products, and numerous others not mentioned. However, this test method, described within, is specifically for round containers.
1.6The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM F 2097 : 2016 | Standard Guide for Design and Evaluation of Primary Flexible Packaging for Medical Products |
ASTM E 177 : 2014 : REDLINE | Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods |
ASTM D 4332 : 2000 | Standard Practice for Conditioning Containers, Packages, or Packaging Components for Testing |
ASTM D 4332 : 2001 : EDT 1 | Standard Practice for Conditioning Containers, Packages, or Packaging Components for Testing |
ASTM D 4332 : 2001 : R2006 | Standard Practice for Conditioning Containers, Packages, or Packaging Components for Testing |
ASTM D 4332 : 2014 | Standard Practice for Conditioning Containers, Packages, or Packaging Components for Testing |
ASTM D 4332 : 2001 : EDT 2 | Standard Practice for Conditioning Containers, Packages, or Packaging Components for Testing |
ASTM D 4332 : 1999 | Standard Practice for Conditioning Containers, Packages, or Packaging Components for Testing |
ASTM D 4332 : 2013 | Standard Practice for Conditioning Containers, Packages, or Packaging Components for Testing |
ASTM D 4332 : 2001 | Standard Practice for Conditioning Containers, Packages, or Packaging Components for Testing |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.