ASTM F 1690 : 1996
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Specification for Humidifiers for Medical Use-Part 1 General Requirements for Active Humidification Systems
Hardcopy , PDF
11-11-2014
English
01-01-1996
CONTAINED IN VOL. 13.01, 2012 Specifies requirements for the safety and performance of active vaporizing and nebulizing humidification systems, suitable for inclusion in breathing systems (both intubated and non-intubated patients).
Committee |
F 29
|
DocumentType |
Standard
|
Pages |
17
|
ProductNote |
Reconfirmed 1996
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 The requirements given in Clause 1 of the General Standard apply with the following additions and modifications:
1.1.1 Replace 1.1 with the following:
1.1.1.1 This specification includes requirements for the safety and performance of active vaporizing and nebulizing humidification systems, as defined in 3.6, suitable for inclusion in breathing systems (both intubated and nonintubated patients).
1.1.1.2 This specification also includes requirements for breathing tubes, including heated breathing tubes (heated-wire breathing circuits), and devices intended to control these heated breathing tubes, heated breathing tube controllers.
1.1.1.3 Heat and moisture exchangers (HMEs) are outside the scope of this specification. However, it is recognized that their safety and performance may affect that of humidification systems. Numerous studies have been published citing the benefits and risks of HMEs used in conjunction with humidification systems. It is advisable to review the instructions for use provided with the humidification systems and HMEs and the available literature for more details.
1.1.1.4 Devices commonly referred to as "room humidifiers," humidifiers used in heating, ventilation, and airconditioning systems and humidifiers used to condition the environment within infant incubators are outside the scope of this specification.
1.1.1.5 It has not been found possible to include guidance on the matter of droplet size in the case of nebulizing humidifiers.
1.1.1.6 Gas-powered nebulizers used for the delivery of drugs to patients through their respiratory system are outside the scope of this specification.
1.1.1.7 Appendices in this specification are not mandatory unless made so by an explicit statement in the main text.
1.2 The values stated in SI units are to be regarded as the standard.
ASTM F 1054 : 2001 | Standard Specification for Conical Fittings (Withdrawn 2005) |
IEC 60601-2-19:2009+AMD1:2016 CSV | Medical electrical equipment - Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators |
ISO 3744:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
CGA G 4.3 : 2015 | COMMODITY SPECIFICATION FOR OXYGEN |
ISO 4135:2001 | Anaesthetic and respiratory equipment Vocabulary |
ISO 8835-2:2007 | Inhalational anaesthesia systems Part 2: Anaesthetic breathing systems |
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV | Sound level meters |
IEC 60801-2:1991 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 2: Electrostatic discharge requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.