• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM E 1667 : 1995 : REV A : R2018

Current

Current

The latest, up-to-date edition.

Standard Classification for Serviceability of an Office Facility for Image to the Public and Occupants

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-03-2018

£52.98
Excluding VAT

CONTAINED IN VOL. 04.11, 2018 Defines pairs of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements for image to the public and occupants.

Committee
E 06
DocumentType
Standard
Pages
14
ProductNote
Reconfirmed 2018
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1This classification covers pairs of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements for image to the public and occupants.

1.2Within that aspect of serviceability, each pair of scales, shown in Figs. 1-7, are for classifying one topic of serviceability. Each paragraph in an Occupant Requirement Scale (see Figs. 1-7) summarizes one level of serviceability on that topic, which occupants might require. The matching entry in the Facility Rating Scale (see Figs. 1-7) is a translation of the requirement into a description of certain features of a facility which, taken in combination, indicate that the facility is likely to meet that level of required serviceability.

FIG. 1Scale A.11.1 for Exterior Appearance

Scale A.11.1 for Exterior AppearanceScale A.11.1 for Exterior Appearance

FIG. 1 Scale A.11.1 for Exterior Appearance (continued)

 Scale A.11.1 for Exterior Appearance Scale A.11.1 for Exterior Appearance

FIG. 2Scale A.11.2 for Public Lobby of Building

Scale A.11.2 for Public Lobby of BuildingScale A.11.2 for Public Lobby of Building

FIG. 2Scale A.11.2 for Public Lobby of Building (continued)

Scale A.11.2 for Public Lobby of BuildingScale A.11.2 for Public Lobby of Building

FIG. 3Scale A.11.3 for Public Spaces Within the Building

Scale A.11.3 for Public Spaces Within the BuildingScale A.11.3 for Public Spaces Within the Building

FIG. 3Scale A.11.3 for Public Spaces Within the Building (continued)

Scale A.11.3 for Public Spaces Within the BuildingScale A.11.3 for Public Spaces Within the Building

FIG. 4Scale A.11.4 for Appearance and Spaciousness of Office Spaces

Scale A.11.4 for Appearance and Spaciousness of Office SpacesScale A.11.4 for Appearance and Spaciousness of Office Spaces

FIG. 5Scale A.11.5 for Finishes and Materials in Office Spaces

Scale A.11.5 for Finishes and Materials in Office SpacesScale A.11.5 for Finishes and Materials in Office Spaces

FIG. 6Scale A.11.6 for Identity Outside the Building

Scale A.11.6 for Identity Outside the BuildingScale A.11.6 for Identity Outside the Building

FIG. 6Scale A.11.6 for Identity Outside the Building (continued)

Scale A.11.6 for Identity Outside the BuildingScale A.11.6 for Identity Outside the Building

FIG. 7 Scale A.11.7 for Neighborhood and Site

 Scale A.11.7 for Neighborhood and Site Scale A.11.7 for Neighborhood and Site

FIG. 7Scale A.11.7 for Neighborhood and Site (continued)

Scale A.11.7 for Neighborhood and SiteScale A.11.7 for Neighborhood and Site

1.3The entries in the Facility Rating Scale (see Figs. 1-7) are indicative and not comprehensive. They are for quick scanning to estimate approximately, quickly, and economically, how well an office facility is likely to meet the needs of one or another type of occupant group over time. The entries are not for measuring, knowing, or evaluating how an office facility is performing.

1.4This classification can be used to estimate the level of serviceability of an existing facility. It can also be used to estimate the serviceability of a facility that has been planned but not yet built, such as one for which single-line drawings and outline specifications have been prepared.

1.5This classification indicates what would cause a facility to be rated at a certain level of serviceability but does not state how to conduct a serviceability rating nor how to assign a serviceability score. That information is found in Practice E1334. The scales in this classification are complimentary to and compatible with Practice E1334. Each requires the other.

1.6The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM E 1700 : 2016 Standard Classification for Serviceability of an Office Facility for Structure and Building Envelope<rangeref></rangeref >
ASTM E 1765 : 2016 Standard Practice for Applying Analytical Hierarchy Process (AHP) to Multiattribute Decision Analysis of Investments Related to Projects, Products, and Processes

ASTM E 631 : 2015 : REDLINE Standard Terminology of Building Constructions
ASTM E 1679 : 2013 : R2019 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility, and for Determining What Serviceability is Provided or Proposed
ISO 6240:1980 Performance standards in building Contents and presentation
ASTM E 1679 : 1995 : R2012 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility
ASTM E 631 : 2015 : R2024 Standard Terminology of Building Constructions
ASTM E 1679 : 1995 : R1999 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility
ASTM E 1679 : 1995 : R2005 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility
ASTM E 631 : 2015 Standard Terminology of Building Constructions
ASTM E 1334 : 1995 : R2005 Standard Practice for Rating the Serviceability of a Building or Building-Related Facility
ASTM E 1679 : 2013 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility, and for Determining What Serviceability is Provided or Proposed
ASTM E 1679 : 2013 : REDLINE Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility, and for Determining What Serviceability is Provided or Proposed
ASTM E 1334 : 1995 : R1999 Standard Practice for Rating the Serviceability of a Building or Building-Related Facility

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.