1.1These test methods cover the determination of gold in ore processing cyanide solutions within the following ranges:
Method | Application Range, |
Inductively Coupled Plasma Mass Spectrometry | 0.001 to 0.500 |
Flame Atomic Absorption Spectrometry | 0.300 to 10.0 |
Note 1:The lower limit for the Inductively Coupled Plasma Mass Spectrometry Method, 0.001 µg/mL, was set following the guidance of Practice E1601. The reproducibility Index, R, was calculated using the total standard deviation for the lowest concentration Youden pair solution.
1.1.1These test methods may also be applied to cyanide leach solutions from metallurgical evaluation procedures.
1.2The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3The test methods appear in the following order:
Method | Sections |
Flame Atomic Absorption Spectrometry | 9 – 16 |
Inductively Coupled Plasma Mass Spectrometry | 17 – 24 |
1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautions are given in 11.1, 11.1.1, 11.5, and 12.2.
ASTM D 5673 : 2005 | Standard Test Method for Elements in Water by Inductively Coupled Plasma-Mass Spectrometry |
ASTM E 29 : 2013 : R2019 | Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications |
ASTM D 7237 : 2018 | Standard Test Method for Free Cyanide and Aquatic Free Cyanide with Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection |
ASTM E 1060 : 1985 : R1995 : EDT 1 | Practice for Interlaboratory Testing of Spectrochemical Methods of Analysis (Withdrawn 1997) |
ASTM D 6888 : 2003 | Standard Test Method for Available Cyanide with Ligand Displacement and Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection |
ASTM D 2777 : 2012 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM E 29 : 2002 | Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications |
ASTM D 1193 : 1977 : R1983 : EDT 1 | Standard Specification for Reagent Water |
ASTM E 135 : 2021 : REV A | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM D 6888 : 2016 | Standard Test Method for Available Cyanides with Ligand Displacement and Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection |
ASTM D 5673 : 2015 | Standard Test Method for Elements in Water by Inductively Coupled Plasma—Mass Spectrometry |
ASTM D 2777 : 2003 | Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water |
ASTM D 2777 : 2021 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 5673 : 2016 | Standard Test Method for Elements in Water by Inductively Coupled Plasma—Mass Spectrometry |
ASTM D 2777 : 2013 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 5673 : 1996 | Standard Test Method for Elements in Water by Inductively Coupled Plasma—Mass Spectrometry |
ASTM D 2777 : 1998 | Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water |
ASTM D 6888 : 2009 | Standard Test Method for Available Cyanide with Ligand Displacement and Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection |
ASTM E 135 : 2003 : REV B | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM D 1193 : 2006 : R2011 | Standard Specification for Reagent Water |
ASTM E 1601 : 2019 | Standard Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical Method |
ASTM D 6888 : 2004 | Standard Test Method for Available Cyanide with Ligand Displacement and Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection |
ASTM E 1601 : 1998 | Standard Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical Method |
ASTM D 1293 : 1999 | Standard Test Methods for pH of Water |
ASTM E 1601 : 2010 | Standard Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical Method |
ASTM D 7237 : 2010 | Standard Test Method for Free Cyanide with Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection |
ASTM D 1193 : 1991 | Standard Specification for Reagent Water |
ASTM E 135 : 2002 : REV A | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM D 5673 : 2003 | Standard Test Method for Elements in Water by Inductively Coupled Plasma—Mass Spectrometry |
ASTM D 7237 : 2015 : REV A | Standard Test Method for Free Cyanide and Aquatic Free Cyanide with Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection |
ASTM D 7237 : 2006 | Standard Test Method for Aquatic Free Cyanide with Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection |
ASTM E 135 : 2022 : REV B | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM D 1293 : 1999 : R2005 | Standard Test Methods for pH of Water |
ASTM E 1601 : 2012 | Standard Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical Method |
ASTM D 5673 : 2010 | Standard Test Method for Elements in Water by Inductively Coupled Plasma-Mass Spectrometry |
ASTM D 2777 : 2008 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 1293 : 2018 | Standard Test Methods for pH of Water |
ASTM E 135 : 2022 : REV A | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM D 2777 : 2006 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM E 135 : 2021 | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 135 : 2003 | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM E 135 : 2003 : REV C | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM D 1193 : 1970 | Standard Specification For Reagent Water |
ASTM E 173 : 1993 | Practice for Conducting Interlaboratory Studies of Methods for Chemical Analysis of Metals (Withdrawn 1997) |
ASTM D 1193 : 2006 | Standard Specification for Reagent Water |
ASTM E 135 : 2022 | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM D 5673 : 2002 | Standard Test Method for Elements in Water by Inductively Coupled Plasma—Mass Spectrometry |
ASTM E 50 : 1982 : R1986 | Standard Practices for Apparatus, Reagents, and Safety Precautions for Chemical Analysis of Metals |
ASTM D 1293 : 2012 | Standard Test Methods for pH of Water |
ASTM D 1193 : 1999 | Standard Specification for Reagent Water |
ASTM D 7237 : 2015 | Standard Test Method for Free Cyanide and Aquatic Free Cyanide with Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection |
ASTM E 135 : 2020 : REV B | Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials |
ASTM D 1193 : 2006 : R2018 | Standard Specification for Reagent Water |
ASTM D 2777 : 2008 : EDT 1 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 1293 : 1984 : R1990 | Standard Test Methods for pH of Water |
ASTM E 29 : 2022 | Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.