ASTM D 92 : 2018
Current
The latest, up-to-date edition.
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester
Hardcopy , PDF
English
01-07-2018
1.1 This test method describes the determination of the flash point and fire point of petroleum products by a manual Cleveland open cup apparatus or an automated Cleveland open cup apparatus.
Committee |
D 02
|
DocumentType |
Test Method
|
Pages |
11
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
Supersedes |
1.1This test method describes the determination of the flash point and fire point of petroleum products by a manual Cleveland open cup apparatus or an automated Cleveland open cup apparatus.
Note 1:The precisions for fire point were not determined in the current interlaboratory program. Fire point is a parameter that is not commonly specified, although in some cases, knowledge of this flammability temperature may be desired.
1.2This test method is applicable to all petroleum products with flash points above 79 °C (175 °F) and below 400 °C (752 °F) except fuel oils.
Note 2:This test method may occasionally be specified for the determination of the fire point of a fuel oil. For the determination of the flash points of fuel oils, use Test Method D93. Test Method D93 should also be used when it is desired to determine the possible presence of small but significant concentrations of lower flash point substances that may escape detection by Test Method D92. Test Method D1310 can be employed if the flash point is known to be below 79 °C (175 °F).
1.3The values stated in SI units are to be regarded as the standard.
1.3.1Exception—The values given in parentheses are for information only.
1.4WARNING—Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Use Caution when handling mercury and mercury-containing products. See the applicable product Safety Data Sheet (SDS) for additional information. The potential exists that selling mercury or mercury-containing products, or both, is prohibited by local or national law. Users must determine legality of sales in their location.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.4, 7.1, 11.1.3, and 11.2.4.
1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
MIL-DTL-25681 Revision F:2022 | Lubricant, Molybdenum Disulfide, Silicone (NATO S-1735) |
NFPA 34:2024 | Standard for Dipping, Coating, and Printing Processes Using Flammable or Combustible Liquids |
ASTM D 4057 : 2019 | Standard Practice for Manual Sampling of Petroleum and Petroleum Products |
ASTM D 4057 : 1995 | Standard Practice for Manual Sampling of Petroleum and Petroleum Products |
ASTM D 4177 : 2016 : EDT 1 | Standard Practice for Automatic Sampling of Petroleum and Petroleum Products |
ASTM D 4206 : 1996 : R2007 | Standard Test Method for Sustained Burning of Liquid Mixtures Using the Small Scale Open-Cup Apparatus |
ASTM D 4177 : 1995 | Standard Practice for Automatic Sampling of Petroleum and Petroleum Products |
ASTM D 4057 : 2012 : R2018 | Standard Practice for Manual Sampling of Petroleum and Petroleum Products |
ASTM D 4206 : 1996 : R2001 | Standard Test Method for Sustained Burning of Liquid Mixtures Using the Small Scale Open-Cup Apparatus |
ASTM D 4057 : 1981 : EDT 2 | Standard Practice for Manual Sampling of Petroleum and Petroleum Products |
ASTM D 93 : 2019 | Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester |
ASTM D 1310 : 2014 | Standard Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus |
ASTM D 4206 : 1996 : R2024 | Standard Test Method for Sustained Burning of Liquid Mixtures Using the Small Scale Open-Cup Apparatus |
ASTM D 1310 : 1986 : R1997 : EDT 1 | Standard Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus |
ASTM D 93 : 1990 : EDT 1 | Standard Test Methods for Flash Point by Pensky-Martens Closed Tester |
ASTM D 1310 : 2001 | Standard Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus |
ASTM D 4057 : 2006 | Standard Practice for Manual Sampling of Petroleum and Petroleum Products |
ASTM D 4177 : 2015 | Standard Practice for Automatic Sampling of Petroleum and Petroleum Products |
ASTM D 4206 : 1996 | Standard Test Method for Sustained Burning of Liquid Mixtures Using the Small Scale Open-Cup Apparatus |
ASTM E 300 : 2003 : R2022 | Standard Practice for Sampling Industrial Chemicals |
ASTM D 4057 : 2012 | Standard Practice for Manual Sampling of Petroleum and Petroleum Products |
ASTM D 4206 : 1996 : R2018 | Standard Test Method for Sustained Burning of Liquid Mixtures Using the Small Scale Open-Cup Apparatus |
ASTM D 4177 : 2022 | Standard Practice for Automatic Sampling of Petroleum and Petroleum Products |
ASTM D 4177 : 1995 : R2010 | Standard Practice for Automatic Sampling of Petroleum and Petroleum Products |
ASTM D 4206 : 1996 : R2013 | Standard Test Method for Sustained Burning of Liquid Mixtures Using the Small Scale Open-Cup Apparatus |
ASTM D 4177 : 1995 : R2000 | Standard Practice for Automatic Sampling of Peroleum and Petroleum Products |
ASTM D 1310 : 2001 : R2007 | Standard Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus |
ASTM D 1310 : 2014 : R2021 | Standard Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus |
ASTM D 93 : 2000 | Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester |
ASTM E 1 : 2014 : R2020 | Standard Specification for ASTM Liquid-in-Glass Thermometers |
ASTM D 93 : 1985 | Standard Test Method for Flash Point by Pensky-Martens Closed Tester |
ASTM E 300 : 2003 : R2017 | Standard Practice for Sampling Industrial Chemicals |
ASTM D 4057 : 2022 | Standard Practice for Manual Sampling of Petroleum and Petroleum Products |
ASTM D 4177 : 2016 | Standard Practice for Automatic Sampling of Petroleum and Petroleum Products |
ASTM D 4177 : 2020 | Standard Practice for Automatic Sampling of Petroleum and Petroleum Products |
ASTM D 4177 : 1995 : R2005 | Standard Practice for Automatic Sampling of Petroleum and Petroleum Products |
ASTM D 4057 : 1995 : R2000 | Standard Practice for Manual Sampling of Petroleum and Petroleum Products |
ASTM D 4177 : 2022 : EDT 1 | Standard Practice for Automatic Sampling of Petroleum and Petroleum Products |
ASTM D 93 : 1997 | Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester |
ASTM D 4177 : 2015 : REV A | Standard Practice for Automatic Sampling of Petroleum and Petroleum Products |
ASTM D 4057 : 2006 : R2011 | Standard Practice for Manual Sampling of Petroleum and Petroleum Products |
ASTM D 93 : 2018 | Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.