Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers
Hardcopy , PDF
19-10-2023
English
12-06-2017
This practice describes a micro-scale chamber apparatus and associated procedures for rapidly screening materials and products for their vapor-phase emissions of volatile organic compounds (VOCs) including formaldehyde and other carbonyl compounds.
Committee |
D 22
|
DocumentType |
Standard Practice
|
Pages |
10
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This practice describes a micro-scale chamber apparatus and associated procedures for rapidly screening materials and products for their vapor-phase emissions of volatile organic compounds (VOCs) including formaldehyde and other carbonyl compounds. It is intended to complement, not replace reference methods for measuring chemical emissions for example, small-scale chamber tests (Guide D5116) and emission cell tests (Practice D7143).
1.2This practice is suitable for use in and outside of laboratories, in manufacturing sites and in field locations with access to electrical power.
1.3Compatible material/product types that may be tested in the micro-scale chamber apparatus include rigid materials, dried or cured paints and coatings, compressible products, and small, irregularly-shaped components such as polymer beads.
1.4This practice describes tests to correlate emission results obtained from the micro-scale chamber with results obtained from VOC emission reference methods (for example, Guide D5116, Test Method D6007, Practice D7143, and ISO 16000-9 and ISO 16000-10).
1.5The micro-scale chamber apparatus operates at moderately elevated temperatures, 30°C to 60°C, to eliminate the need for cooling, to reduce test times, boost emission rates, and enhance analytical signals for routine emission screening, and to facilitate screening of semi-volatile VOC (SVOC) emissions such as emissions of some phthalate esters and other plasticizers.
1.6Gas sample collection and chemical analysis are dependent upon the nature of the VOCs targeted and are beyond the scope of this practice. However, the procedures described in Test Method D7339, Practice D6196 and ISO 16000-6 for analysis of VOCs and in Test Method D5197 and ISO 16000-3 for analysis of formaldehyde and other carbonyl compounds are applicable to this practice.
1.7The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.9This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D 6670 : 2018 | Standard Practice for Full-Scale Chamber Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM D 7339 : 2018 | Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography |
ASTM D 7911 : 2014 | Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test |
ASTM D 8142 : 2017 | Standard Test Method for Determining Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation using Micro-Scale Environmental Test Chambers |
ASTM D 5116 : 2017 | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products |
ASTM D 8141 : 2017 | Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Parameters for Modeling of Indoor Environments |
ASTM D 7911 : 2019 | Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test |
ASTM D 8141 : 2022 | Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Parameters for Modeling of Indoor Environments |
ASTM D 1914 : 1995 : R2022 | Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres |
ASTM D 7339 : 2007 | Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography |
ASTM D 7339 : 2018 | Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography |
ASTM D 1356 : 2015 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 6196 : 1997 | Standard Practice for Selection of Sorbents and Pumped Sampling/Thermal Desorption Analysis Procedures for Volatile Organic Compunds in Air |
ASTM D 5116 : 2006 | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials/Products |
ASTM D 1356 : 2017 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 6007 : 2014 | Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber |
ASTM D 5337 : 2023 | Standard Practice for Setting and Verifying the Flow Rate of Personal Sampling Pumps |
ASTM D 6196 : 2003 : R2009 | Standard Practice for Selection of Sorbents, Sampling, and Thermal Desorption Analysis Procedures for Volatile Organic Compounds in Air |
ASTM D 1356 : 2015 : REV B | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 5116 : 2010 | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials/Products |
ASTM D 7143 : 2011 : R2016 | Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM D 6196 : 2015 : EDT 1 | Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air |
ASTM D 6196 : 2015 | Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air |
ASTM D 5337 : 2011 : R2016 | Standard Practice for Flow Rate Adjustment of Personal Sampling Pumps |
ASTM D 1356 : 2014 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 6196 : 2023 | Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air |
ASTM D 5116 : 2017 | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products |
ASTM D 7143 : 2005 | Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM D 5197 : 1997 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 1914 : 1995 : R1999 | Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis Atmospheres |
ASTM D 6007 : 2022 | Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber |
ASTM D 5337 : 1997 | Standard Practice for Flow Rate for Calibration of Personal Sampling Pumps |
ASTM D 1356 : 2015 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2005 : R2010 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 6007 : 2002 : R2008 | Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using a Small Scale Chamber |
ASTM D 6196 : 2003 | Standard Practice for Selection of Sorbents, Sampling, and Thermal Desorption Analysis Procedures for Volatile Organic Compounds in Air |
ASTM D 5197 : 2016 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 5197 : 2009 : EDT 1 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 1356 : 2020 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 6007 : 2002 | Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using a Small Scale Chamber |
ASTM D 7339 : 2012 | Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography |
ASTM D 7143 : 2017 | Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products |
ASTM D 1914 : 1995 : R2014 | Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2000 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 5197 : 2021 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 5116 : 1997 | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products (Withdrawn 2006) |
ASTM D 5337 : 2011 | Standard Practice for Flow Rate for Calibration of Personal Sampling Pumps |
ASTM D 1356 : 2014 : REV B | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2014 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1914 : 1995 : R2010 | Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres |
ASTM D 5337 : 2004 | Standard Practice for Flow Rate for Calibration of Personal Sampling Pumps |
ASTM D 1356 : 2005 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 6007 : 1996 | Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using a Small Scale Chamber |
ASTM D 1914 : 1995 : R2004 : EDT 1 | Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres |
ASTM D 5197 : 2003 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 5197 : 2009 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 7143 : 2011 | Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.