ASTM D 7597 : 2016 : R2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Determination of Diisopropyl Methylphosphonate, Ethyl Hydrogen Dimethylamidophosphate, Ethyl Methylphosphonic Acid, Isopropyl Methylphosphonic Acid, Methylphosphonic Acid and Pinacolyl Methylphosphonic Acid in Water by Liquid Chromatography/Tandem Mass Spectrometry
Hardcopy , PDF
20-05-2024
English
13-07-2017
CONTAINED IN VOL. 11.02, 2018 Defines the determination of diisopropyl methylphosphonate (DIMP), ethyl hydrogen dimethylamidophosphate (EHDMAP), ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA), methylphosphonic acid (MPA) and pinacolyl methylphosphonic acid (PMPA) (referred to collectively as organophosphonates in this test method) in surface water by direct injection using liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS) using electrospray ionization (ESI).
Committee |
D 19
|
DocumentType |
Test Method
|
Pages |
13
|
ProductNote |
Reconfirmed 2017
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This procedure covers the determination of diisopropyl methylphosphonate (DIMP), ethyl hydrogen dimethylamidophosphate (EHDMAP), ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA), methylphosphonic acid (MPA) and pinacolyl methylphosphonic acid (PMPA) (referred to collectively as organophosphonates in this test method) in surface water by direct injection using liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS) using electrospray ionization (ESI). These analytes are qualitatively and quantitatively determined by this test method. This test method adheres to single reaction monitoring (SRM) mass spectrometry.
1.2This test method has been developed by U.S. EPA Region 5 Chicago Regional Laboratory (CRL).
1.3The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4The detection verification level (DVL) and reporting range for the organophosphonates are listed in Table 1.
TABLE 1 Detection Verification Level and Reporting Range
Analyte | ESI Mode | DVL (μg/L) | Reporting Range (μg/L) |
Diisopropyl methylphosphonate | Positive | 1 | 5–150 |
Ethyl hydrogen dimethylamidophosphate | Negative | 0.25 | 5–150 |
Ethyl hydrogen dimethylamidophosphate | Positive | 0.25 | 5–150 |
Ethyl methylphosphonic acid | Negative | 5 | 50–1500 |
Ethyl methylphosphonic acid | Positive | 5 | 50–1500 |
Isopropyl methylphosphonic acid | Negative | 10 | 50–1500 |
Isopropyl Methylphosphonic acid | Positive | 5 | 50–1500 |
Methylphosphonic acid | Negative | 20 | 100–1500 |
Methylphosphonic acid | Positive | 10 | 50–1500 |
Pinacolyl methylphosphonic acid | Negative | 5 | 50–1500 |
Pinacolyl methylphosphonic acid | Positive | 5 | 50–1500 |
1.4.1The DVL is required to be at a concentration at least three times below the reporting limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 displays the signal/noise ratios at the DVLs for the organophosphonates in the ESI positive mode and Fig. 2 in the ESI negative mode.
FIG. 1Example ESI Positive Mode SRM Chromatograms Signal/Noise Ratios
FIG. 2Example ESI Negative Mode SRM Chromatograms Signal/Noise Ratios
1.4.2The reporting limit is the concentration of the Level 1 calibration standard as shown in Table 2 for the organophosphonates except for MPA in the ESI negative mode which is at Level 2 due to not meeting the DVL criteria at the lower concentration level. The DVL for MPA in the ESI negative mode is at 20 μg/L, which forces a raised reporting limit. However, the multi-laboratory validation required a spike of all target analytes at Level 1 concentrations. The mean recovery for MPA in the ESI negative mode at this level was 98.7 % as shown in Table 3. If your instrument’s sensitivity can meet the requirements in this test method, MPA may have a 50 μg/L reporting limit.
TABLE 2 Concentrations of Calibration Standards (PPB)
Analyte/Surrogate | LV 1 | LV 2 | LV 3 | LV 4 | LV 5 | LV 6 | LV 7 |
Diisopropyl methylphosphonate | 5 | 10 | 20 | 35 | 50 | 100 | 150 |
Ethyl hydrogen dimethylamidophosphate | 5 | 10 | 20 | 35 | 50 | 100 | 150 |
Ethyl methylphosphonic acid | 50 | 100 | 200 | 350 | 500 | 1000 | 1500 |
Isopropyl methylphosphonic acid | 50 | 100 | 200 | 350 | 500 | 1000 | 1500 |
Methylphosphonic acid | 50 | 100 | 200 | 350 | 500 | 1000 | 1500 |
Pinacolyl methylphosphonic acid | 50 | 100 | 200 | 350 | 500 | 1000 | 1500 |
DIMP-D14 (Surrogate) | 5 | 10 | 20 | 35 | 50 | 100 | 150 |
PMPA-13C4 (Surrogate) | 25 | 50 | 100 | 175 | 250 | 500 | 750 |
MPA-D3 (Surrogate) | 25 | 50 | 100 | 175 | 250 | 500 | 750 |
TABLE 3 Multi-Laboratory Recovery Data in Reagent Water
Analyte | ESI | Spike Conc. | # Results | # Labs | Bias | Precision | |||||
Mean | Min | Max | Overall SD | Pooled | Overall | Pooled | |||||
DIMP | Pos | 5 | 16 | 4 | 95.1 | 65.8 | 136.0 | 17.6 | 19.4 | 21.3 | 22.4 |
DIMP | Pos | 10 | 19 | 5 | 98.2 | 80.0 | 121.0 | 6.1 | 5.5 | 13.6 | 13.8 |
DIMP | Pos | 25 | 26 | 6 | 102.9 | 74.4 | 128.0 | 5.6 | 5.7 | 14.5 | 14.1 |
DIMP | Pos | 125 | 22 | 5 | 96.6 | 80.4 | 120.0 | 4.4 | 4.5 | 11.0 | 11.4 |
DIMP-D14 | Pos | 25 | 86 | 6 | 102.6 | 54.8 | 127.6 | 9.8 | 9.5 | 11.2 | 10.9 |
EHDMAP | Neg | 5 | 12 | 3 | 57.5 | 0.0 | 220.0 | 31.4 | 22.3 | 71.1 | 123.6 |
EHDMAP | Neg | 10 | 16 | 4 | 47.1 | 0.0 | 178.0 | 13.3 | 10.8 | 66.8 | 142.0 |
EHDMAP | Neg | 25 | 22 | 5 | 84.1 | 54.0 | 141.2 | 6.9 | 6.6 | 22.9 | 27.3 |
EHDMAP | Neg | 125 | 18 | 4 | 87.4 | 64.2 | 141.6 | 5.0 | 5.1 | 25.4 | 29.1 |
EHDMAP | Pos | 5 | 16 | 4 | 77.0 | 0.0 | 134.2 | 7.4 | 8.0 | 51.4 | 66.8 |
EHDMAP | Pos | 10 | 20 | 5 | 70.0 | 0.0 | 143.0 | 7.7 | 10.0 | 53.6 | 76.5 |
EHDMAP | Pos | 25 | 26 | 6 | 89.6 | 60.0 | 128.8 | 5.2 | 6.2 | 23.5 | 26.2 |
EHDMAP | Pos | 125 | 22 | 5 | 87.5 | 59.0 | 123.2 | 5.2 | 6.0 | 23.9 | 27.3 |
EMPA | Neg | 50 | 16 | 4 | 110.1 | 74.8 | 170.6 | 22.4 | 17.2 | 25.6 | 23.3 |
EMPA | Neg | 100 | 20 | 5 | 108.3 | 87.7 | 175.0 | 11.1 | 8.7 | 24.8 | 22.9 |
EMPA | Neg | 250 | 26 | 6 | 104.8 | 82.0 | 122.6 | 6.1 | 5.5 | 11.8 | 11.3 |
EMPA | Neg | 1250 | 22 | 5 | 101.5 | 87.2 | 126.4 | 8.4 | 8.1 | 11.2 | 11.0 |
EMPA | Pos | 50 | 16 | 4 | 95.4 | 77.6 | 122.8 | 12.9 | 13.3 | 13.1 | 13.7 |
EMPA | Pos | 100 | 20 | 5 | 96.0 | 61.4 | 132.5 | 9.5 | 9.5 | 15.9 | 16.6 |
EMPA | Pos | 250 | 26 | 6 | 99.7 | 70.0 | 133.2 | 5.9 | 5.4 | 18.2 | 18.2 |
EMPA | Pos | 1250 | 21 | 5 | 93.9 | 84.0 | 108.4 | 2.7 | 3.0 | 7.7 | 8.2 |
IMPA | Neg | 50 | 16 | 4 | 88.0 | 56.6 | 140.4 | 23.7 | 26.0 | 23.5 | 26.7 |
IMPA | Neg | 100 | 20 | 5 | 88.0 | 68.5 | 118.0 | 12.9 | 14.3 | 13.4 | 15.2 |
IMPA | Neg | 250 | 26 | 6 | 98.1 | 72.8 | 144.0 | 13.1 | 11.9 | 19.2 | 19.6 |
IMPA | Neg | 1250 | 21 | 5 | 90.7 | 73.1 | 103.0 | 5.5 | 6.1 | 8.7 | 9.6 |
IMPA | Pos | 50 | 16 | 4 | 98.3 | 47.8 | 139.6 | 19.2 | 20.5 | 27.2 | 27.7 |
IMPA | Pos | 100 | 19 | 5 | 95.4 | 72.3 | 120.5 | 9.8 | 10.3 | 12.4 | 13.0 |
IMPA | Pos | 250 | 26 | 6 | 97.0 | 79.2 | 188.4 | 7.4 | 7.6 | 10.9 | 11.2 |
IMPA | Pos | 1250 | 21 | 5 | 91.3 | 70.4 | 115.5 | 5.1 | 5.2 | 11.4 | 12.5 |
MPA | Neg | 50 | 16 | 4 | 98.7 | 3.3 | 175.0 | 14.2 | 25.3 | 60.5 | 61.3 |
MPA | Neg | 100 | 20 | 5 | 100.0 | 41.9 | 142.0 | 8.9 | 9.2 | 30.8 | 30.8 |
MPA | Neg | 250 | 26 | 6 | 99.5 | 66.0 | 124.5 | 7.6 | 7.6 | 14.5 | 14.5 |
MPA | Neg | 1250 | 22 | 5 | 102.7 | 81.8 | 130.5 | 10.5 | 9.9 | 12.4 | 12.1 |
MPA | Pos | 50 | 16 | 4 | 68.3 | 9.8 | 139.6 | 13.4 | 20.3 | 36.6 | 53.6 |
MPA | Pos | 100 | 20 | 5 | 80.5 | 48.4 | 149.7 | 14.0 | 12.6 | 26.8 | 33.3 |
MPA | Pos | 250 | 26 | 6 | 91.7 | 33.9 | 153.7 | 8.0 | 7.8 | 31.8 | 34.7 |
MPA | Pos | 1250 | 22 | 5 | 95.8 | 31.8 | 208.2 | 12.6 | 8.3 | 43.4 | 45.3 |
MPA-D3 | Neg | 250 | 84 | 6 | 111.2 | 57.2 | 190.8 | 16.2 | 12.5 | 30.0 | 26.9 |
MPA-D3 | Pos | 250 | 68 | 5 | 104.4 | 58.4 | 151.8 | 14.3 | 14.0 | 18.0 | 17.3 |
PMPA | Neg | 50 | 15 | 4 | 87.8 | 77.6 | 124.4 | 8.4 | 8.2 | 13.8 | 15.7 |
PMPA | Neg | 100 | 19 | 5 | 91.6 | 83.6 | 98.2 | 2.8 | 3.0 | 4.4 | 4.8 |
PMPA | Neg | 250 | 26 | 6 | 101.0 | 77.2 | 123.8 | 5.0 | 4.8 | 12.1 | 12.0 |
PMPA | Neg | 1250 | 22 | 5 | 99.2 | 84.8 | 126.5 | 4.9 | 4.8 | 12.3 | 12.4 |
PMPA | Pos | 50 | 16 | 4 | 90.8 | 60.8 | 148.8 | 15.8 | 16.1 | 25.6 | 28.2 |
PMPA | Pos | 100 | 15 | 4 | 95.2 | 86.8 | 114.0 | 3.8 | 4.0 | 7.9 | 8.3 |
PMPA | Pos | 250 | 20 | 5 | 103.8 | 85.2 | 136.1 | 4.5 | 3.8 | 15.3 | 14.7 |
PMPA | Pos | 1250 | 12 | 3 | 99.8 | 88.8 | 117.5 | 5.2 | 5.0 | 7.5 | 7.5 |
PMPA-13C6 | Neg | 250 | 83 | 6 | 99.5 | 74.8 | 128.3 | 9.4 | 9.2 | 11.1 | 11.1 |
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D 3694 : 1996 : R2011 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 1129 : 2013 : REDLINE | Standard Terminology Relating to Water |
ASTM D 1129 : 2003 | Standard Terminology Relating to Water |
ASTM D 2777 : 2013 : REDLINE | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 1129 : 2013 | Standard Terminology Relating to Water |
ASTM D 1129 : 2013 : R2020 | Standard Terminology Relating to Water |
ASTM D 5847 : 1999 : REV A : EDT 1 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 3694 : 1996 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 2777 : 2012 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 1129 : 2013 : R2020 : EDT 2 | Standard Terminology Relating to Water |
ASTM D 1193 : 1977 : R1983 : EDT 1 | Standard Specification for Reagent Water |
ASTM D 5847 : 2002 : R2007 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 1129 : 2006 | Standard Terminology Relating to Water |
ASTM D 2777 : 2003 | Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water |
ASTM D 2777 : 2021 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 2777 : 2013 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM E 2554 : 2013 | Standard Practice for Estimating and Monitoring the Uncertainty of Test Results of a Test Method Using Control Chart Techniques |
ASTM D 5847 : 2002 : R2012 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 2777 : 1998 | Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water |
ASTM D 3694 : 1996 : R2017 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 1129 : 2013 : R2020 : EDT 1 | Standard Terminology Relating to Water |
ASTM D 1129 : 1999 : REV A | Standard Terminology Relating to Water |
ASTM D 3856 : 2011 | Standard Guide for Management Systems in Laboratories Engaged in Analysis of Water |
ASTM D 1129 : 2006 : REV A | Standard Terminology Relating to Water |
ASTM D 1193 : 2006 : R2011 | Standard Specification for Reagent Water |
ASTM D 5847 : 2002 : R2020 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 1129 : 2003 : REV A | Standard Terminology Relating to Water |
ASTM D 3694 : 1996 : R2004 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 1129 : 2002 | Standard Terminology Relating to Water |
ASTM E 2554 : 2018 : EDT 1 | Standard Practice for Estimating and Monitoring the Uncertainty of Test Results of a Test Method Using Control Chart Techniques |
ASTM D 1193 : 1991 | Standard Specification for Reagent Water |
ASTM D 3856 : 1995 : R2006 | Standard Guide for Good Laboratory Practices in Laboratories Engaged in Sampling and Analysis of Water |
ASTM D 1129 : 2004 | Standard Terminology Relating to Water |
ASTM D 5847 : 2022 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM D 2777 : 2008 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM E 2554 : 2007 | Standard Practice for Estimating and Monitoring the Uncertainty of Test Results of a Test Method in a Single Laboratory Using a Control Sample Program |
ASTM D 3856 : 2011 : R2015 | Standard Guide for Management Systems in Laboratories Engaged in Analysis of Water (Withdrawn 2024) |
ASTM D 2777 : 2006 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
ASTM D 3856 : 1995 : R2000 | Standard Guide for Good Laboratory Practices in Laboratories Engaged in Sampling and Analysis of Water |
ASTM D 1129 : 2002 : REV A | Standard Terminology Relating to Water |
ASTM E 2554 : 2018 | Standard Practice for Estimating and Monitoring the Uncertainty of Test Results of a Test Method Using Control Chart Techniques |
ASTM D 5847 : 2002 | Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis |
ASTM E 2554 : 2013-05 | PRACTICE FOR ESTIMATING AND MONITORING THE UNCERTAINTY OF TEST RESULTS OF A TEST METHOD USING CONTROL CHART TECHNIQUES |
ASTM D 1193 : 1970 | Standard Specification For Reagent Water |
ASTM D 1193 : 2006 | Standard Specification for Reagent Water |
ASTM D 1193 : 1999 | Standard Specification for Reagent Water |
ASTM D 1129 : 2010 | Standard Terminology Relating to Water |
ASTM D 1129 : 2006 : REV A : EDT 1 | Standard Terminology Relating to Water |
ASTM D 1129 : 2001 | Standard Terminology Relating to Water |
ASTM D 1129 : 2004 : EDT 1 | Standard Terminology Relating to Water |
ASTM D 3694 : 1996 : R2024 | Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents |
ASTM D 1193 : 2006 : R2018 | Standard Specification for Reagent Water |
ASTM D 2777 : 2008 : EDT 1 | Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.