• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM D 6903 : 2007 : R2013

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Determination of Organic Biocide Release Rate From Antifouling Coatings in Substitute Ocean Water

Available format(s)

Hardcopy , PDF

Superseded date

20-08-2020

Language(s)

English

Published date

01-06-2013

£82.93
Excluding VAT

CONTAINED IN VOL. 06.02, 2018 Defines the laboratory determination of the rate at which organic biocide is released from an antifouling coating exposed in substitute ocean water.

Committee
D 01
DocumentType
Test Method
Pages
21
ProductNote
Reconfirmed 2013
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This test method covers the laboratory determination of the rate at which organic biocide is released from an antifouling coating exposed in substitute ocean water. The test is run entirely in the laboratory under controlled conditions of pH, temperature, salinity, and hydrodynamics. Analytical procedures are provided for the determination of the release rate of 4,5-dichloro-2-n-octylisothiazolin-3-one (DCOIT), zinc and copper pyrithione (ZPT and CuPT), and N-cyclopropyl-N-(1,1-dimethylethyl)-6-(methylthio)-1,3,5-triazine-2,4-diamine (CDMTD). At predetermined intervals, substitute ocean water samples are analyzed for leached biocide using a suitable analytical technique.

1.2In cases in which the antifouling coating contains both an organic biocide and a copper-based biocide, the release rate of copper may optionally be concurrently determined according to the procedure found in Test Method D6442.

1.3The procedure contains the preparation steps for the determination of the release rate of biocide in substitute ocean water from antifouling paints including apparatus, reagents, holding tank conditions, and sampling point details. The procedure calls for the accurate determination of organic biocide concentrations in substitute ocean water at the low μg L-1  (parts per billion, ppb) level. To detect and correct for reagent impurities and allow a suitable level of analytical precision to be achieved, the analytical method to be used for the determination of the concentration of organic biocide in substitute ocean water must meet the acceptability criteria given in Annex A2. Where Annex A2 specifies a limit of quantitation (LOQ), the procedure for determining the LOQ for the organic biocide in substitute ocean water by the analytical method presented in Annex A3 is to be followed.

1.4Suitable analytical methods that use high-performance liquid chromatography (HPLC) for determining the concentration of DCOIT, ZPT and CuPT, and CDMTD in substitute ocean water are given in Appendix X1-Appendix X3, respectively. Other methods may be used provided that they meet the appropriate criteria given in Annex A2.

1.5When the release rate of a highly photosensitive organic biocide is being determined, steps must be taken to protect the apparatus and samples from exposure to natural and artificial visible light sources. Any such requirement for these steps to be taken for a particular biocide is indicated in Annex A2.

1.6The practical limits for quantifying biocide release rates by this method are from 4.5 to 500 μg cm-2 d-1 for DCOIT, 0.36 to 500 μg cm-2 d-1 for CuPT, 0.36 to 500 μg cm-2 d-1 for ZPT, and 2.7 to 500 μg cm-2 d-1 for CDMTD. These ranges may be extended to 3.8 to 500 μg cm-2 d-1 for DCOIT, 0.16 to 500 μg cm-2 d-1 for CuPT, 0.2 to 500 μg cm-2 d-1 for ZPT, and 2.2 to 500 μg cm-2 d-1 for CDMTD if the procedures described in Appendix X1-Appendix X3 (as appropriate) are followed. The quantitation of release rates lower than these ranges will require the use of analytical methods with lower limits of quantitation than those specified in Annex A2.

1.7The results of this test method do not reflect environmental biocide release rates for antifouling products, and are not suitable for direct use in the process of generating environmental risk assessments, environmental loading estimates, or for establishing release rate limits for regulatory purposes. See also Section 4.

1.8The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.9This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM D 1005 : 1995 : R2020 Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers
ASTM D 1141 : 1998 : R2008 Standard Practice for the Preparation of Substitute Ocean Water
ASTM D 1141 : 1998 : EDT 1 Standard Practice for the Preparation of Substitute Ocean Water
ASTM D 1193 : 1977 : R1983 : EDT 1 Standard Specification for Reagent Water
ASTM D 6442 : 2006 : R2012 Standard Test Method for Determination of Copper Release Rate From Antifouling Coatings in Substitute Ocean Water
ASTM D 1005 : 1995 : R2001 Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers
ASTM D 1193 : 2006 : R2011 Standard Specification for Reagent Water
ASTM D 1141 : 1998 : R2013 Standard Practice for the Preparation of Substitute Ocean Water
ASTM D 1005 : 1995 : R2013 Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers
ASTM D 1193 : 1991 Standard Specification for Reagent Water
ASTM D 6442:2006 Standard Test Method for Determination of Copper Release Rate From Antifouling Coatings in Substitute Ocean Water
ASTM D 6442 : 1999 Standard Test Method for Copper Release Rates of Antifouling Coating Systems in Seawater
ASTM D 6442 : 2003 Standard Test Method for Determination of Copper Release Rate From Antifouling Coating Systems in Artificial Seawater
ASTM D 1193 : 1970 Standard Specification For Reagent Water
ASTM D 1005 : 1995 : R2007 Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers
ASTM D 1193 : 2006 Standard Specification for Reagent Water
CFR 40(PTS136-149) : JUL 2017 PROTECTION OF ENVIRONMENT - ENVIRONMENTAL PROTECTION AGENCY
ASTM D 1193 : 1999 Standard Specification for Reagent Water
ASTM D 6442 : 2005 Standard Test Method for Determination of Copper Release Rate From Antifouling Coatings in Substitute Ocean Water
ASTM D 1193 : 2006 : R2018 Standard Specification for Reagent Water
ASTM D 1005 : 1995 Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers
ASTM D 1141 : 1998 : R2003 Standard Practice for the Preparation of Substitute Ocean Water

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.