Standard Practice for Direct Push Installation of Prepacked Screen Monitoring Wells in Unconsolidated Aquifers

Available format(s)

PDF

Language(s)

English

Published date

15-07-2016

£63.73
Excluding VAT

CONTAINED IN VOL. 04.09, 2016 Defines methods by which direct push monitoring wells may be designed and installed for the purpose of detecting the presence or absence of a contaminant, and collecting representative groundwater quality data.

Committee
D 18
DevelopmentNote
Supersedes ASTM D 6725. (08/2016)
DocumentType
Redline
Pages
16
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1This practice is based on recognized methods by which direct push monitoring wells may be designed and installed for the purpose of detecting the presence or absence of a contaminant, and collecting representative groundwater quality data. The design standards and installation procedures herein are applicable to both detection and assessment monitoring programs for facilities.

1.2The recommended monitoring well design, as presented in this practice, is based on the assumption that the objective of the program is to obtain representative groundwater information and water quality samples from aquifers. Monitoring wells constructed following this practice should produce relatively turbidity-free samples for granular aquifer materials ranging from gravels to silty sand.

1.3Direct push procedures are not applicable for monitoring well installation under all geologic and soil conditions (for example, installation in bedrock). Other rotary drilling procedures are available for penetration of these consolidated materials for well construction purposes (Guide D5092). Additionally, under some geologic conditions it may be appropriate to install monitoring wells without a filter pack (1, 2)2. Guide D6724 may be referred to for additional information on these and other methods for the direct push installation of groundwater monitoring wells.

1.4The values stated in either inch-pound units or SI units presented in brackets are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.5All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026, unless superseded by this standard.

1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.7This practice offers a set of instructions for performing one or more specific operations. This document cannot replace education or experience and should be used in conjunction with professional judgement. Not all aspects of this practice may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of the project's many unique aspects. The word “Standard” in the title of this document means only that the document has been approved through the ASTM consensus process.

ASTM D 6282 : 1998 Standard Guide for Direct Push Soil Sampling for Environmental Site Characterizations
ASTM D 4043 : 2017 : REDLINE Standard Guide for Selection of Aquifer Test Method in Determining Hydraulic Properties by Well Techniques
ASTM D 4044 : 1996 Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifiers
ASTM D 4104 : 1996 Standard Test Method (Analytical Procedure) for Determining Transmissivity of Nonleaky Confined Aquifers by Overdamped Well Response to Instantaneous Change in Head (Slug Tests)
ASTM D 3740 : 2012-06 PRACTICE FOR MINIMUM REQUIREMENTS FOR AGENCIES ENGAGED IN TESTING AND/OR INSPECTION OF SOIL AND ROCK AS USED IN ENGINEERING DESIGN AND CONSTRUCTION
ASTM D 5786 : 2017 : REDLINE Standard Practice for (Field Procedure) for Constant Drawdown Tests in Flowing Wells for Determining Hydraulic Properties of Aquifer Systems
ASTM D 5434 : 2012 Standard Guide for Field Logging of Subsurface Explorations of Soil and Rock (Withdrawn 2021)
ASTM D 6286 : 2012 : REDLINE Standard Guide for Selection of Drilling Methods for Environmental Site Characterization
ASTM D 5787 : 2014 : REDLINE Standard Practice for Monitoring Well Protection
ASTM D 5521 : 2005 Standard Guide for Development of Groundwater Monitoring Wells in Granular Aquifers
ASTM D 6771 : 2002 Standard Practice for Low-Flow Purging and Sampling for Wells and Devices Used for Ground-Water Quality Investigations (Withdrawn 2011)
ASTM D 7242 : 2006 Standard Practice for Field Pneumatic Slug (Instantaneous Change in Head) Tests to Determine Hydraulic Properties of Aquifers with Direct Push Groundwater Samplers
ASTM D 7929 : 2014 Standard Guide for Selection of Passive Techniques for Sampling Groundwater Monitoring Wells
ASTM D 6026 : 2013 : REDLINE Standard Practice for Using Significant Digits in Geotechnical Data
ASTM D 653 : 2014 : REDLINE Standard Terminology Relating to Soil, Rock, and Contained Fluids

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.