ASTM D 6662 : 2017 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Specification for Polyolefin-Based Plastic Lumber Decking Boards
29-04-2022
English
29-03-2017
CONTAINED IN VOL. 08.03, 2017 Explains polyolefin-based plastic lumber products for use as exterior residential decking boards.
Committee |
D 20
|
DocumentType |
Redline
|
Pages |
15
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This specification covers polyolefin-based plastic lumber products for use as exterior residential decking boards.
1.2Plastic lumber products are currently made predominantly with recycled polyolefin plastics (in particular high-density polyethylene) where the products are more or less non-homogenous in the cross-section. However, this specification is also potentially applicable to similar manufactured plastic products made from other plastic and plastic composite materials that have non-homogenous cross-sections.
1.3This specification details a procedure to calculate recommended span lengths for spacing of support joists. This procedure was developed using experimental data from a typical unreinforced plastic lumber made predominantly from recycled high-density polyethylene. The methodology to develop span lengths for other types and compositions of plastic lumber is detailed in Appendix X1 of this standard.
1.4The values are stated in inch-pound units, as these are currently the most common units used by the construction industry. Equivalent SI units are indicated in parentheses. However, the units stated for irradiance exposure in the weatherability section (6.3) are in SI units as these are the units commonly used for testing of this type.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Note 1:There is no similar or equivalent ISO Standard.
ASTM E 2726/E2726M : 2012 : REV A : R2017 | Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands |
NFPA 1144 : 2018 | REDUCING STRUCTURE IGNITION HAZARDS FROM WILDLAND FIRE |
ASTM E 2957 : 2017 : REDLINE | Standard Test Method for Resistance to Wildfire Penetration of Eaves, Soffits and Other Projections |
ASTM D 7031 : 2011 : REDLINE | GUIDE FOR EVALUATING MECHANICAL AND PHYSICAL PROPERTIES OF WOOD-PLASTIC COMPOSITE PRODUCTS |
ASTM D 7568 : 2017 : REDLINE | Standard Specification for Polyethylene-Based Structural-Grade Plastic Lumber for Outdoor Applications |
ASTM E 2707 : 2015 : REDLINE | Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure |
ICC IWUIC INTERNATIONAL WILDLAND U.I. CODE : 2015 | INTERNATIONAL WILDLAND-URBAN INTERFACE CODE |
ICC 2012 INT. WILDLAND U.I. CODE : 2012 | INTERNATIONAL WILDLAND-URBAN INTERFACE CODE |
ASTM E 2726/E2726M : 2012 | Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands |
ASTM D 7032 : 2017 : REDLINE | Standard Specification for Establishing Performance Ratings for Wood-Plastic Composite and Plastic Lumber Deck Boards, Stair Treads, Guards, and Handrails |
ASTM D 7258 : 2017 : REDLINE | Standard Specification for Polymeric Piles |
ASTM E 2726/E2726M : 2012 : REV A | Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands |
ASTM D 4329 : 2013 : REDLINE | Standard Practice for Fluorescent Ultraviolet (UV) Lamp Apparatus Exposure of Plastics |
ASTM E 108 : 2017 : REDLINE | Standard Test Methods for Fire Tests of Roof Coverings |
ASTM G 154 : 2016 : REDLINE | Standard Practice for Operating Fluorescent Ultraviolet (UV) Lamp Apparatus for Exposure of Nonmetallic Materials |
ASTM D 6341 : 2016 : REDLINE | Standard Test Method for Determination of the Linear Coefficient of Thermal Expansion of Plastic Lumber and Plastic Lumber Shapes Between –30 and 140°F (–34.4 and 60°C) |
ASTM G 155 : 2013 : REDLINE | Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials |
ASTM D 2565 : 2016 : REDLINE | Standard Practice for Xenon-Arc Exposure of Plastics Intended for Outdoor Applications |
ASTM D 2915 : 2017 : REDLINE | Standard Practice for Sampling and Data-Analysis for Structural Wood and Wood-Based Products |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.