Standard Test Method for Determination of Aerosol Monomeric and Oligomeric Hexamethylene Diisocyanate (HDl) in Air with (Methoxy-2–phenyl-1) Piperazine (MOPIP) in the Workplace

Available format(s)

Hardcopy , PDF

Superseded date

12-08-2020

Superseded by

ASTM D 6561 : 2020

Language(s)

English

Published date

01-11-2016

£57.59
Excluding VAT

CONTAINED IN VOL. 11.07, 2017 Specifies the determination of aerosol hexamethylene diisocyanate (HDI) in air samples collected from workplace and ambient atmospheres.

Committee
D 22
DocumentType
Test Method
Pages
6
ProductNote
Reconfirmed 2016
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This test method covers the determination of aerosol hexamethylene diisocyanate (HDI) in air samples collected from workplace and ambient atmospheres. The method described in this test method collects separate fractions. One fraction will be dominated by vapor, and the other fraction will be dominated by aerosol. It is not known at the present time whether this represents a perfect separation of vapor and aerosol, and in any case, there are not separate exposure standards for vapor and aerosol. Therefore, in comparing the results for isocyanate against a standard, results from the two fractions should be combined to give a single total value. The reason for splitting the sample into two fractions is to increase analytic sensitivity for the vapor fraction and also to give the hygienist or ventilation engineer some information concerning the likely state of the isocyanate species. The analyses of the two fractions are different, and are provided in separate, linked, standards to avoid confusion. This test method is principally used to determine short term exposure (15 min) of HDI in workplace environments for personal monitoring or in ambient air. The analysis of the vapor fraction is performed separately, as described in Test Method D6562.

1.2Differential air sampling is performed with a segregating device.2 The aerosol fraction is collected on a polytetrafluoroethylene (PTFE) filter.

1.3Immediately after sampling, the PTFE filter is transferred into a jar containing a (methoxy-2 phenyl-1) piperazine (MOPIP) solution in toluene.

1.4The analysis of the aerosol fraction is performed by using a high performance liquid chromatograph (HPLC) equipped with an ultraviolet (UV) detector. The range of application of the test method has been validated from 0.052 to 1.04 μg of monomeric HDI/mL, which corresponds, based on a 15 L air sample, to concentrations from 0.004 to 0.070 mg/m3 of HDI. Those concentrations correspond to a range of aerosol phase concentrations from 0.5 ppb (V) to 10 ppb (V) and cover the established threshold limit valve (TLV) value of 5 ppb (V).

1.5The quantification limit for the monomeric HDI is 0.041 μg per mL, which corresponds to 0.003 mg/m3 for a 15 L sampled air volume. This value is equivalent to ten times the standard deviation obtained from ten measurements carried out on a standard solution in contact with the PTFE filter whose concentration of 0.1 μg/mL is close to the expected detection limit.

1.6The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 9 for additional hazards.

ASTM D 6562 : 2012 Standard Test Method for Determination of Gaseous Hexamethylene Diisocyanate (HDI) in Air with 9-(N-methylaminomethyl) Anthracene Method (MAMA) in the Workplace
ASTM D 4844 : 2016 Standard Guide for Air Monitoring at Waste Management Facilities for Worker Protection

ASTM D 1356 : 2015 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 1357 : 1995 : R2019 Standard Practice for Planning the Sampling of the Ambient Atmosphere
ASTM D 1357 : 1995 : R2000 Standard Practice for Planning the Sampling of the Ambient Atmosphere
ASTM D 1193 : 1977 : R1983 : EDT 1 Standard Specification for Reagent Water
ASTM D 1357 : 1995 : R2005 Standard Practice for Planning the Sampling of the Ambient Atmosphere
ASTM D 6562 : 2012 Standard Test Method for Determination of Gaseous Hexamethylene Diisocyanate (HDI) in Air with 9-(N-methylaminomethyl) Anthracene Method (MAMA) in the Workplace
ASTM D 1356 : 2017 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 6562 : 2006 Standard Test Method for Determination of Gaseous Hexamethylene Diisocyanate (HDI) in Air with 9-(N-methylaminomethyl) Anthracene Method (MAMA) in the Workplace
ASTM D 1356 : 2015 : REV B Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 1357 : 1995 : R2011 Standard Practice for Planning the Sampling of the Ambient Atmosphere
ASTM D 1193 : 2006 : R2011 Standard Specification for Reagent Water
ASTM D 5337 : 2011 : R2016 Standard Practice for Flow Rate Adjustment of Personal Sampling Pumps
ASTM D 1356 : 2014 : REV A Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 1193 : 1991 Standard Specification for Reagent Water
ASTM D 6562 : 2000 Standard Test Method for Determination of Gaseous Hexamethylene Diisocyanate (HDI) in Air with 9-(N-methylaminomethyl) Anthracene Method (MAMA) in the Workplace
ASTM D 5337 : 1997 Standard Practice for Flow Rate for Calibration of Personal Sampling Pumps
ASTM D 1356 : 2015 : REV A Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 6562 : 2006 : R2011 Standard Test Method for Determination of Gaseous Hexamethylene Diisocyanate (HDI) in Air with 9-(N-methylaminomethyl) Anthracene Method (MAMA) in the Workplace
ASTM D 1356 : 2005 : R2010 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 1356 : 2020 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 1356 : 2000 : REV A Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 5337 : 2011 Standard Practice for Flow Rate for Calibration of Personal Sampling Pumps
ASTM D 6562 : 2012 : REDLINE Standard Test Method for Determination of Gaseous Hexamethylene Diisocyanate (HDI) in Air with 9-(N-methylaminomethyl) Anthracene Method (MAMA) in the Workplace
ASTM D 1193 : 1970 Standard Specification For Reagent Water
ASTM D 1356 : 2014 : REV B Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 1356 : 2014 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 1193 : 2006 Standard Specification for Reagent Water
ASTM D 1193 : 1999 Standard Specification for Reagent Water
ASTM D 5337 : 2004 Standard Practice for Flow Rate for Calibration of Personal Sampling Pumps
ASTM D 1356 : 2005 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 1193 : 2006 : R2018 Standard Specification for Reagent Water

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.