• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM D 6442 : 2006 : R2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Determination of Copper Release Rate From Antifouling Coatings in Substitute Ocean Water

Available format(s)

Hardcopy , PDF

Superseded date

20-08-2020

Language(s)

English

Published date

01-08-2012

£57.59
Excluding VAT

CONTAINED IN VOL. 06.02, 2018 Determines the rate at which copper is released from an antifouling (AF) coating in substitute ocean water.

Committee
D 01
DocumentType
Test Method
Pages
10
ProductNote
Reconfirmed 2012
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This test method covers the laboratory determination of the rate at which copper is released from an antifouling (AF) coating in substitute ocean water. The practical limits for quantifying copper release rates by this method are from 1.8 to 500 μg cm-2d-1. This range may be extended to 0.2 to 500 μg cm-2d-1 if the analytical procedure described in Appendix X1 is followed.

Note 1The term “substitute ocean water” is used throughout this standard to refer to artificial or synthetic seawater prepared in accordance with Practice D1141.

1.2The procedure contains the preparation steps for the release rate determination of copper from antifouling paints including apparatus, reagents, holding tank conditions, and sampling point details. Analysis for the concentration of copper in substitute ocean water requires the accurate determination of copper at the low parts μg L-1 (parts per billion, ppb) level. To detect and correct for reagent impurities, acceptable analytical precision standards are necessary. Therefore, the limit of quantitation (LOQ) for copper in substitute ocean water for the analytical method shall be 10 μg L-1 (10 ppb) or less. The procedure for determining the LOQ for copper in substitute ocean water for the analytical method is found in Annex A2.

1.3A suitable method is described in Appendix X1 (graphite furnace atomic absorption spectroscopy, GF-AAS). Other analytical methods may be utilized with relevant procedural changes, as needed, to accommodate selected specific methods. Such methods must meet the limit of quantitation for copper in substitute ocean water of 10 μg L-1(10 ppb) or less. See 1.2.

1.4This results of this test method do not reflect environmental copper release rates for antifouling products, and are not suitable for direct use in the process of generating environmental risk assessments, environmental loading estimates, or for establishing release rate limits for regulatory purposes. See also Section 4 on Significance and Use.

1.5The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety practices and to determine the applicability of regulatory limits prior to use. For specific hazard statements, see Section 7.

ASTM D 6903 : 2007 : R2013 Standard Test Method for Determination of Organic Biocide Release Rate From Antifouling Coatings in Substitute Ocean Water

ASTM D 1005 : 1995 : R2020 Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers
ASTM D 1141 : 1998 : R2008 Standard Practice for the Preparation of Substitute Ocean Water
ASTM D 1141 : 1998 : EDT 1 Standard Practice for the Preparation of Substitute Ocean Water
ASTM D 1193 : 1977 : R1983 : EDT 1 Standard Specification for Reagent Water
ASTM D 1005 : 1995 : R2001 Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers
ASTM D 1193 : 2006 : R2011 Standard Specification for Reagent Water
ASTM D 1141 : 1998 : R2013 Standard Practice for the Preparation of Substitute Ocean Water
ASTM D 1005 : 1995 : R2013 Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers
ASTM D 1193 : 1991 Standard Specification for Reagent Water
ASTM D 1193 : 1970 Standard Specification For Reagent Water
ASTM D 1005 : 1995 : R2007 Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers
ASTM D 1193 : 2006 Standard Specification for Reagent Water
ASTM D 1193 : 1999 Standard Specification for Reagent Water
ASTM D 1193 : 2006 : R2018 Standard Specification for Reagent Water
ASTM D 1005 : 1995 Standard Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers
ASTM D 1141 : 1998 : R2003 Standard Practice for the Preparation of Substitute Ocean Water

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.