ASTM D 6399 : 2018
Current
The latest, up-to-date edition.
Standard Guide for Selecting Instruments and Methods for Measuring Air Quality in Aircraft Cabins
Hardcopy , PDF
English
01-04-2018
Committee |
D 22
|
DocumentType |
Guide
|
Pages |
12
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
Supersedes |
1.1This guide covers information and guidance for the selection of instrumentation and test methods for measuring air quality in aircraft passenger cabins as well as in areas limited to flightcrew access.
1.2This guide assumes that a list of pollutants to be measured, or analytes of interest, which are present, or may be present, in aircraft cabins is available.
1.3This guide provides information and guidance to identify levels of concern pertaining to public and occupational exposures to relevant air pollutants. This guide does not address levels of concern, if any, related to degradation of materials or aircraft components because of the presence of air pollutants.
1.4Based on levels of concern for public and occupational exposures for each pollutant of interest, this guide provides recommendations for developing three aspects of data quality objectives (a) detection limit; (b) precision; and (c) bias.
1.5This guide summarizes information on technologies for measurement of different groups or classes of air pollutants to provide a basis for selection of instruments and methods. The guide also identifies information resources on types of available measurement systems.
1.6This guide provides general recommendations for selection of instruments and methods. These recommendations are based on concepts associated with data quality objectives discussed in this guide and the information on available instruments and methods summarized in this guide.
1.7This guide is specific to chemical contaminants and does not address bioaerosols, which may be present in the cabin environment.
1.8This guide does not provide details on use or operation of instruments or methods for the measurement of cabin air quality.
1.9This guide does not provide information on the design of a monitoring strategy, including issues such as frequency of measurement or placement of samplers.
1.10Users of this guide should be familiar with, or have access to, individuals who have a background in (a) use of instruments and methods for measurement of air pollutants and (b) principles of toxicology and health-effects of environmental exposure to air pollutants.
1.11The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.12This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.13This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D 7034 : 2018 | Standard Guide for Deriving Acceptable Levels of Airborne Chemical Contaminants in Aircraft Cabins Based on Health and Comfort Considerations |
ASTM D 7659 : 2010 : R2015 | Standard Guide for Strategies for Surface Sampling of Metals and Metalloids for Worker Protection |
ASTM D 1914 : 1995 : R2022 | Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres |
ASTM D 4490 : 1996 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Detector Tubes |
ASTM D 4490 : 1996 : R2016 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Detector Tubes |
ASTM D 5466 : 1995 | Standard Test Method for Determination of Volatile Organic Chemicals in Atmospheres (Canister Sampling Methodology) |
ASTM D 5156 : 1995 | Standard Test Methods for Continuous Measurement of Ozone in Ambient, Workplace, and Indoor Atmospheres (Ultraviolet Absorption) |
ASTM D 5149 : 1995 | Standard Test Method for Ozone in the Atmosphere: Continuous Measurement by Ethylene Chemiluminescence |
ASTM D 1356 : 2015 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 5466 : 2015 | Standard Test Method for Determination of Volatile Organic Compounds in Atmospheres (Canister Sampling Methodology) |
ASTM D 6196 : 1997 | Standard Practice for Selection of Sorbents and Pumped Sampling/Thermal Desorption Analysis Procedures for Volatile Organic Compunds in Air |
ASTM D 5156 : 2002 : R2016 | Standard Test Methods for Continuous Measurement of Ozone in Ambient, Workplace, and Indoor Atmospheres (Ultraviolet Absorption) |
ASTM D 6245 : 2024 | Standard Guide on the Relationship of Indoor Carbon Dioxide Concentrations to Indoor Air Quality and Ventilation |
ASTM D 3162 : 2021 | Standard Test Method for Carbon Monoxide in the Atmosphere (Continuous Measurement by Nondispersive Infrared Spectrometry) |
ASTM D 7034 : 2004 | Standard Guide for Deriving Acceptable Levels of Airborne Chemical Contaminants in Aircraft Cabins Based on Health and Comfort Considerations |
ASTM D 4861 : 2023 | Standard Practice for Sampling and Selection of Analytical Techniques for Pesticides and Polychlorinated Biphenyls in Air |
ASTM D 5156 : 2022 | Standard Test Methods for Continuous Measurement of Ozone in Ambient, Workplace, and Indoor Atmospheres (Ultraviolet Absorption) |
ASTM D 6196 : 2015 : EDT 1 | Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air |
ASTM D 4861 : 2017 | Standard Practice for Sampling and Selection of Analytical Techniques for Pesticides and Polychlorinated Biphenyls in Air (Withdrawn 2021) |
ASTM D 6245 : 2018 | Standard Guide for Using Indoor Carbon Dioxide Concentrations to Evaluate Indoor Air Quality and Ventilation |
ASTM D 6196 : 2015 | Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air |
ASTM D 6196 : 2023 | Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air |
ASTM D 6245 : 1998 | Standard Guide for Using Indoor Carbon Dioxide Concentrations to Evaluate Indoor Air Quality and Ventilation |
ASTM D 5197 : 1997 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 4490 : 2023 | Standard Practice for the Use of Detector Tubes in the Measurement of Toxic Gases and Vapors |
ASTM D 1914 : 1995 : R1999 | Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis Atmospheres |
ASTM D 1356 : 2015 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 5197 : 2016 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 3162 : 2012 : R2020 | Standard Test Method for Carbon Monoxide in the Atmosphere (Continuous Measurement by Nondispersive Infrared Spectrometry) |
ASTM D 5149 : 2024 | Standard Test Method for Ozone in the Atmosphere: Continuous Measurement by Ethylene Chemiluminescence |
ASTM D 1914 : 1995 : R2014 | Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2000 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 5197 : 2021 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 4023 : 1982 : REV A : R1996 | Standard Terminology Relating to Humidity Measurements (Withdrawn 2002) |
ASTM D 1356 : 2014 : REV B | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 5466 : 2021 | Standard Test Method for Determination of Volatile Organic Compounds in Atmospheres (Canister Sampling, Mass Spectrometry Analysis Methodology) |
ASTM D 4861 : 2000 | Standard Practice for Sampling and Selection of Analytical Techniques for Pesticides and Polychlorinated Biphenyls in Air |
ASTM D 3162 : 1994 : R2000 : EDT 1 | Standard Test Method for Carbon Monoxide in the Atmosphere (Continuous Measurement by Nondispersive Infrared Spectrometry) |
ASTM D 5149 : 2002 : R2016 | Standard Test Method for Ozone in the Atmosphere: Continuous Measurement by Ethylene Chemiluminescence |
ASTM D 3631 : 1999 | Standard Test Methods for Measuring Surface Atmospheric Pressure |
ASTM D 3631 : 1999 : R2017 | Standard Test Methods for Measuring Surface Atmospheric Pressure |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-