Standard Test Method for (Analytical Procedure) Determining Hydraulic Conductivity of an Unconfined Aquifer by Overdamped Well Response to Instantaneous Change in Head (Slug)

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

01-01-1996

£50.68
Excluding VAT

CONTAINED IN VOL. 04.09, 2009 The procedure in this test method is used in conjunction with the field procedure in Test Method D 4044 for collection of test data, and covers the determination of hydraulic conductivity from the measurement of inertial force free response of a well-aquifer system to a sudden change in water level in a well.

Committee
D 18
DocumentType
Test Method
Pages
4
ProductNote
Reconfirmed EDT 1
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 This test method covers the determination of hydraulic conductivity from the measurement of inertial force free (overdamped) response of a well-aquifer system to a sudden change in water level in a well. Inertial force free response of the water level in a well to a sudden change in water level is characterized by recovery to initial water level in an approximate exponential manner with negligible inertial effects.

1.2 The analytical procedure in this test method is used in conjunction with the field procedure in Test Method D4044 for collection of test data.

1.3 Limitations -Slug tests are considered to provide an estimate of hydraulic conductivity. The determination of storage coefficient is not possible with this test method. Because the volume of aquifer material tested is small, the values obtained are representative of materials very near the open portion of the control well.

Note 1-Slug tests are usually considered to provide estimates of the lower limit of the actual hydraulic conductivity of an aquifer because the test results are so heavily influenced by well efficiency and borehole skin effects near the open portion of the well. The portion of the aquifer that is tested by the slug test is limited to an area near the open portion of the well where the aquifer materials may have been altered during well installation, and therefore may significantly effect the test results. In some cases the data may be misinterpreted and result in a higher estimate of hydraulic conductivity. This is due to the reliance on early time data that is reflective of the hydraulic conductivity of the filter pack surrounding the well. This effect was discussed by Bouwer. In addition, because of the reliance on early time data, in aquifers with medium to high hydraulic conductivity, the early time portion of the curve that is useful for this data analyses is too short (for example, ∧lt;10 s) for accurate measurement; therefore, the test results begin to greatly underestimate the true hydraulic conductivity.

1.4 The values stated in SI units are to be regarded as the standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM D 4104 : 2017 Standard Test Method (Analytical Procedure) for Determining Transmissivity of Nonleaky Confined Aquifers by Overdamped Well Response to Instantaneous Change in Head (Slug Tests)
ASTM D 6725/D6725M : 2016 Standard Practice for Direct Push Installation of Prepacked Screen Monitoring Wells in Unconsolidated Aquifers
ASTM D 7242/D7242M : 2006 : R2013 : EDT 1 Standard Practice for Field Pneumatic Slug (Instantaneous Change in Head) Tests to Determine Hydraulic Properties of Aquifers with Direct Push Groundwater Samplers (Withdrawn 2022)
ASTM D 4044/D4044M : 2015 Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifers (Withdrawn 2024)
ASTM D 4043 : 2017 Standard Guide for Selection of Aquifer Test Method in Determining Hydraulic Properties by Well Techniques

ASTM D 4043 : 2017 : REDLINE Standard Guide for Selection of Aquifer Test Method in Determining Hydraulic Properties by Well Techniques
ASTM D 4044 : 1996 Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifiers
ASTM D 4104 : 1996 Standard Test Method (Analytical Procedure) for Determining Transmissivity of Nonleaky Confined Aquifers by Overdamped Well Response to Instantaneous Change in Head (Slug Tests)
ASTM D 653 : 2014 : REDLINE Standard Terminology Relating to Soil, Rock, and Contained Fluids

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.