ASTM D 5836 : 2008 : R2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Determination of 2,4-Toluene Diisocyanate (2,4-TDI) and 2,6-Toluene Diisocyanate (2,6-TDI) in Workplace Atmospheres (1-2 PP Method)
Hardcopy , PDF
11-08-2020
English
01-04-2013
CONTAINED IN VOL. 11.03, 2017 Specifies the determination of 2,4-toluene diisocyanate (2,4-TDI) and 2,6-toluene diisocyanate (2,6-TDI) in air samples collected from workplace atmospheres in a cassette containing a glass-fiber filter impregnated with 1-(2-pyridyl)piperazine (1-2 PP).
Committee |
D 22
|
DocumentType |
Test Method
|
Pages |
5
|
ProductNote |
Reconfirmed 2013
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This test method describes the determination of 2,4-toluene diisocyanate (2,4-TDI) and 2,6-toluene diisocyanate (2,6-TDI) in air samples collected from workplace atmospheres in a cassette containing a glass-fiber filter impregnated with 1-(2-pyridyl)piperazine (1-2 PP). This procedure is very effective for determining the vapor content of atmospheres. Atmospheres containing aerosols may cause TDI results to be underestimated.
1.2This test method uses a high-performance liquid chromatograph (HPLC) equipped with a fluorescence or an ultraviolet (UV) detector (1-4).2,3
1.3The validated range of the test method, as written, is from 1.4 to 5.6 μg of 2,4-TDI and 2,6-TDI which is equivalent to approximately 9.8 to 39 ppb for 2,4-TDI and 2,6-TDI based on a 20-L air sample. The HPLC method using an UV detector is capable of detecting 0.078 μg of 2,4-TDI and 0.068 μg of 2,6-TDI in a 4.0-mL solvent volume, which is equivalent to 0.55 ppb for 2,4-TDI and 0.48 ppb for 2,6-TDI based on a 20-L air sample.
1.4The isomers of 2,4-TDI, and 2,6-TDI, can be separated utilizing a reversed phase column for the HPLC method. Because industrial applications employ an isomeric mixture of 2,4- and 2,6-TDI, the ability to achieve this separation is important.
1.5The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 9 for specific precautions.
ASTM D 3686 : 2008 | Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method) |
ASTM D 1356 : 2015 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1357 : 1995 : R2019 | Standard Practice for Planning the Sampling of the Ambient Atmosphere |
ASTM D 3686 : 2013 : REDLINE | Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method) |
ASTM D 1357 : 1995 : R2000 | Standard Practice for Planning the Sampling of the Ambient Atmosphere |
ASTM D 1193 : 1977 : R1983 : EDT 1 | Standard Specification for Reagent Water |
ASTM D 1357 : 1995 : R2005 | Standard Practice for Planning the Sampling of the Ambient Atmosphere |
ASTM D 1356 : 2017 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 3686 : 2013 | Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method) |
ASTM D 1356 : 2015 : REV B | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1357 : 1995 : R2011 | Standard Practice for Planning the Sampling of the Ambient Atmosphere |
ASTM D 1193 : 2006 : R2011 | Standard Specification for Reagent Water |
ASTM D 3686 : 1995 | Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method) |
ASTM D 1356 : 2014 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1193 : 1991 | Standard Specification for Reagent Water |
ASTM D 1356 : 2015 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
CFR 29(PT1910.1000 TO END) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR |
ASTM D 1356 : 2005 : R2010 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2020 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2000 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1193 : 1970 | Standard Specification For Reagent Water |
ASTM D 1356 : 2014 : REV B | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2014 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1193 : 2006 | Standard Specification for Reagent Water |
ASTM D 1193 : 1999 | Standard Specification for Reagent Water |
ASTM D 1356 : 2005 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1193 : 2006 : R2018 | Standard Specification for Reagent Water |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.