• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM D 5542 : 2004 : R2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Methods for Trace Anions in High Purity Water by Ion Chromatography

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Superseded by

ASTM D 5542 : 2016

Language(s)

English

Published date

01-05-2009

£57.59
Excluding VAT

Committee
D 19
DocumentType
Test Method
Pages
10
ProductNote
Reconfirmed 2009
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 These test methods cover the determination of trace (μg/L) levels of fluoride, acetate, formate, chloride, phosphate, and sulfate in high purity water using ion chromatography in combination with sample preconcentration. Other anions, such as bromide, nitrite, nitrate, sulfite, and iodide can be determined by this method. However, since they are rarely present in significant concentrations in high purity water, they are not included in this test method. Two test methods are presented and their ranges of application, as determined by a collaborative study, are as follows:

Range Tested
(μg/L Added)
Limit of DetectionA
(Single Operator)
(μg/L)
Sections
Test Method A: 715
Chloride024 0.8
Phosphate039 B
Sulfate055 1.8
Test Method B:1623
Fluoride014 0.7
Acetate04146.8
Formate0346 5.6

A Limit of detection is lowest measurable concentration not reportable as zero at 99 % level of confidence as per EPRI study as cited in Sections 15 and 23.

B Insufficient data to calculate limit of detection.

1.2 It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices.

1.3 The common practical range of Test Method A is as follows: chloride, 1 to 100 μg/L, phosphate, 3 to 100 μg/L, and sulfate, 2 to 100 μg/L.

1.4 The common practical range of Test Method B is as follows: fluoride, 1 to 100 μg/L, acetate, 10 to 200 μg/L, and formate, 5 to 200 μg/L.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

7.1 This test method is optimized for the quantitative determination of trace levels of chloride, phosphate, and sulfate. Anions such as fluoride, acetate, and formate can be detected by this method, but are not reliably resolved from each other. See Fig. 1 for a typical chromatogram.

7.2 Using a concentrated sample volume of 20 mL, the test method is applicable in the range outlined in Section 1. The range of this test method may be extended by concentrating a smaller or a larger sample volume. Be sure not to exceed concentrator column breakthrough volume (see annex).

16.1 This test method is optimized for the quantitative determination of trace levels of fluoride, acetate, and formate in high purity water and in water containing up to 2000 mg/L boron from boric acid. The range of the method is summarized in Section 1. See Fig. 3 for a typical chromatogram.

16.2 This test method does not respond to sulfate, since its elution time is very long.

16.3 Using a concentrated sample volume of 20 mL, the test method is applicable in the range outlined in Section 1. The range of this method may be extended upward by concentrating a smaller sample volume, or downward by concentrating a larger sample volume. When analyzing samples containing high amounts of boric acid (for example, 1 %), the volume concentrated should not exceed 30 mL, so as not to exceed the breakthrough volume for fluoride.


FIG. 3 Anions by Test Method B

ASTM D 5996 : 2016 Standard Test Method for Measuring Anionic Contaminants in High-Purity Water by On-Line Ion Chromatography
ASTM D 8149 : 2017 Standard Practice for Optimization, Calibration, and Validation of Ion Chromatographic Determination of Heteroatoms and Anions in Petroleum Products and Lubricants
ASTM D 5196 : 2006 : R2018 Standard Guide for Bio-Applications Grade Water
ASTM D 1193 : 2006 : R2018 Standard Specification for Reagent Water

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.