ASTM D 4913 : 2000 : R2016
Current
The latest, up-to-date edition.
Standard Practice for Determining Concentration of Hydrogen Sulfide by Direct Reading, Length of Stain, Visual Chemical Detectors (Withdrawn 2023)
Hardcopy , PDF
English
24-10-2016
CONTAINED IN VOL. 11.03, 2017 Defines the detection of hydrogen sulfide gas by visual chemical detectors. Included under visual chemical detectors are: short-term detector tubes, long-term detector tubes, and length-of-stain dosimeters.
Committee |
D 22
|
DocumentType |
Standard Practice
|
Pages |
4
|
ProductNote |
Reconfirmed 2016
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
Supersedes |
1.1This practice covers the detection of hydrogen sulfide gas by visual chemical detectors. Included under visual chemical detectors are: short-term detector tubes (1),2 long-term detector tubes (2), and length-of-stain dosimeters (3). Diffusion tubes are not included under this practice because they are not direct reading, and spot tests are not included because of their poor accuracy. The sample results are immediately available by visual observation, thus no analytical equipment is needed.
1.2This practice reflects the current state-of-the-art for commercially available visual length-of-stain detectors for hydrogen sulfide. Any mention of a specific manufacturer in the text or references does not constitute an endorsement by ASTM.
1.3The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 3686 : 2008 | Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method) |
ASTM D 4599 : 2020 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Length-of-Stain Dosimeters |
ASTM D 4490 : 1996 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Detector Tubes |
ASTM D 4490 : 1996 : R2016 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Detector Tubes |
ASTM D 4599 : 2021 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Length-of-Stain Dosimeters |
ASTM D 1356 : 2015 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 3686 : 2013 : REDLINE | Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method) |
ASTM D 1356 : 2017 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 4599 : 2014 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Length-of-Stain Dosimeters |
ISEA 102 : 1990 | GAS DETECTOR TUBE UNITS - SHORT TERM TYPE FOR TOXIC GASES AND VAPORS IN WORKING ENVIRONMENTS |
ASTM D 3686 : 2013 | Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method) |
ASTM D 1356 : 2015 : REV B | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 4490 : 1996 : R2001 : EDT 1 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Detector Tubes |
ASTM D 3686 : 1995 | Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method) |
ASTM D 4599 : 1997 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Length-of-Stain Dosimeters |
ASTM D 1356 : 2014 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 4599 : 2003 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Length-of-Stain Dosimeters |
ASTM D 1356 : 2015 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
CFR 29(PT1910.1000 TO END) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR |
ASTM D 1356 : 2005 : R2010 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 4599 : 2014 : REDLINE | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Length-of-Stain Dosimeters |
ASTM D 1356 : 2020 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2000 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2014 : REV B | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2014 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 4599 : 2003 : R2009 : EDT 1 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Length-of-Stain Dosimeters |
ASTM D 1356 : 2005 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 4490 : 1996 : R2006 : EDT 1 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Detector Tubes |
ASTM D 4490 : 1996 : R2011 | Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Detector Tubes |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.