Supersedes |
1.1This test method is designed for use in obtaining the specific conductance of a water extract of plastics and fillers. The magnitude of this conductance may be taken as an index of the likelihood that, in a humid atmosphere, metal surfaces in contact with these materials may become corroded due to galvanic action or direct chemical attack; this is called the corrosivity index.
1.2The values stated in SI units are to be regarded as standard.
1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 7.