ASTM D 4104 : 1996
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method (Analytical Procedure) for Determining Transmissivity of Nonleaky Confined Aquifers by Overdamped Well Response to Instantaneous Change in Head (Slug Tests)
Hardcopy , PDF
11-11-2014
English
10-10-1996
Committee |
D 18
|
DocumentType |
Test Method
|
Pages |
4
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This test method covers the determination of transmissivity from the measurement of force-free (overdamped) response of a well-aquifer system to a sudden change of water level in a well. Force-free response of water level in a well to a sudden change in water level is characterized by recovery to initial water level in an approximate exponential manner with negligible inertial effects.
1.2 The analytical procedure in this test method is used in conjunction with the field procedure in Test Method
1.3 Limitations -Slug tests are considered to provide an estimate of transmissivity. The determination of aquifer storage coefficient is less reliable. Although the assumptions of this test method prescribe a fully penetrating well (a well open through the full thickness of the aquifer), the slug test method is commonly conducted using a partially penetrating well. Such a practice may be acceptable for application under conditions in which the aquifer is stratified and horizontal hydraulic conductivity is much greater than vertical hydraulic conductivity. In such a case the test would be considered to be representative of the average hydraulic conductivity of the portion of the aquifer adjacent to the open interval of the well.
1.4 The values stated in SI units are to be regarded as standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 1943 : 1998 : R2004 | Standard Guide for Remediation of Ground Water by Natural Attenuation at Petroleum Release Sites |
ASTM D 3089 : 1997 : R2008 | Standard Practice for Determining the A-D Dimension of Aerosol Valve Dip Tubes |
ASTM D 4044 : 1996 : R2002 | Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifiers |
ASTM D 4043 : 2017 | Standard Guide for Selection of Aquifer Test Method in Determining Hydraulic Properties by Well Techniques |
ASTM D 653 : 2014 | Standard Terminology Relating to Soil, Rock, and Contained Fluids |
ASTM D 6725/D6725M : 2016 | Standard Practice for Direct Push Installation of Prepacked Screen Monitoring Wells in Unconsolidated Aquifers |
ASTM D 6725 : 2004 | Standard Practice for Direct Push Installation of Prepacked Screen Monitoring Wells in Unconsolidated Aquifers |
ASTM D 6725 : 2004 : R2010 | Standard Practice for Direct Push Installation of Prepacked Screen Monitoring Wells in Unconsolidated Aquifers |
ASTM E 1943 : 1998 | Standard Guide for Remediation of Ground Water by Natural Attenuation at Petroleum Release Sites |
ASTM D 4044 : 1996 | Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifiers |
ASTM D 7242 : 2006 | Standard Practice for Field Pneumatic Slug (Instantaneous Change in Head) Tests to Determine Hydraulic Properties of Aquifers with Direct Push Groundwater Samplers |
ASTM D 5912 : 1996 : EDT 1 | Standard Test Method for (Analytical Procedure) Determining Hydraulic Conductivity of an Unconfined Aquifer by Overdamped Well Response to Instantaneous Change in Head (Slug) |
ASCE 34 01 : 2001 | STANDARD GUIDELINES FOR ARTIFICIAL RECHARGE OF GROUND WATER |
ASTM D 6000/D6000M : 2015 : EDT 1 | Standard Guide for Presentation of Water-Level Information from Groundwater Sites (Withdrawn 2024) |
ASTM D 4044/D4044M : 2015 | Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifers (Withdrawn 2024) |
ASTM D 5730 : 2004 | Standard Guide for Site Characterization for Environmental Purposes With Emphasis on Soil, Rock, the Vadose Zone and Groundwater (Withdrawn 2013) |
ASTM D 4043 : 2017 : REDLINE | Standard Guide for Selection of Aquifer Test Method in Determining Hydraulic Properties by Well Techniques |
ASTM E 1943 : 1998 : R2010 | Standard Guide for Remediation of Ground Water by Natural Attenuation at Petroleum Release Sites |
ASTM D 7242/D7242M : 2006 : R2013 : EDT 1 | Standard Practice for Field Pneumatic Slug (Instantaneous Change in Head) Tests to Determine Hydraulic Properties of Aquifers with Direct Push Groundwater Samplers (Withdrawn 2022) |
ASTM D 653 : 2014 : REDLINE | Standard Terminology Relating to Soil, Rock, and Contained Fluids |
ASTM D 5912 : 1996 : R2004 | Standard Test Method for (Analytical Procedure) Determining Hydraulic Conductivity of an Unconfined Aquifer by Overdamped Well Response to Instantaneous Change in Head (Slug) (Withdrawn 2013) |
ASTM D 4044 : 1996 : R2008 | Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifers |
ASTM D 6725/D6725M : 2016 : REDLINE | Standard Practice for Direct Push Installation of Prepacked Screen Monitoring Wells in Unconsolidated Aquifers |
ASTM E 1943 : 1998 : R2015 | Standard Guide for Remediation of Ground Water by Natural Attenuation at Petroleum Release Sites (Withdrawn 2024) |
ASTM D 4044/D4044M : 2015 : REDLINE | Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.